1
-
-
0029832236
-
Guidance with real-time CT fluoroscopy: Early clinical experience
-
Kato K, Kato R, Anno H, et al. Guidance with real-time CT fluoroscopy: early clinical experience. Radiology 1996; 200:851-856.
-
(1996)
Radiology
, vol.200
, pp. 851-856
-
-
Kato, K.1
Kato, R.2
Anno, H.3
-
2
-
-
0031688462
-
Real-time CT. Fluoroscopy: Usefulness in thoracic drainage
-
Meyer CA, White CS, Wu J, Futterer SF, Templeton PA. Real-time CT. Fluoroscopy: usefulness in thoracic drainage. AJR 1998; 171:1097-1101.
-
(1998)
AJR
, vol.171
, pp. 1097-1101
-
-
Meyer, C.A.1
White, C.S.2
Wu, J.3
Futterer, S.F.4
Templeton, P.A.5
-
3
-
-
0031722605
-
Real-time CT fluoroscopy for guidance of percutaneous drainage procedure
-
Floelich JJ, Saar B, Hoppe M, et al. Real-time CT fluoroscopy for guidance of percutaneous drainage procedure. JVIR 1998; 9:735-740.
-
(1998)
JVIR
, vol.9
, pp. 735-740
-
-
Floelich, J.J.1
Saar, B.2
Hoppe, M.3
-
4
-
-
0030833584
-
CT-assisted transbronchial needle aspiration: Usefulness of CT fluoroscopy
-
White CS, Templeton PA, Hasday JD. CT-assisted transbronchial needle aspiration: usefulness of CT fluoroscopy. AJR 1997; 169:393-394.
-
(1997)
AJR
, vol.169
, pp. 393-394
-
-
White, C.S.1
Templeton, P.A.2
Hasday, J.D.3
-
5
-
-
0031676712
-
Evaluation of biopsy needles and prototypic needle guide devices for percutaneous biopsy with CT fluoroscopic guidance in simulated organ tissue
-
Daly B, Templeton PA, Krebs TL, Carroll K, Wong-You-Cheong JJ. Evaluation of biopsy needles and prototypic needle guide devices for percutaneous biopsy with CT fluoroscopic guidance in simulated organ tissue. Radiology 1998; 209:850-855.
-
(1998)
Radiology
, vol.209
, pp. 850-855
-
-
Daly, B.1
Templeton, P.A.2
Krebs, T.L.3
Carroll, K.4
Wong-You-Cheong, J.J.5
-
6
-
-
0029907832
-
Radiation dosimetry at CT fluoroscopy: Physician's hand dose and development of needle holders
-
Kato R, Kato K, Anno H, Suzuki S, Ida Y, Koga S. Radiation dosimetry at CT fluoroscopy: physician's hand dose and development of needle holders. Radiology 1996; 201: 576-578.
-
(1996)
Radiology
, vol.201
, pp. 576-578
-
-
Kato, R.1
Kato, K.2
Anno, H.3
Suzuki, S.4
Ida, Y.5
Koga, S.6
-
7
-
-
0021827065
-
A new universal radiolucent handle
-
Cardella JF, Young AT, Hunter DW, Castaneda-Zuniga WR, Amplatz K. A new universal radiolucent handle. Radiology 1985; 155:531.
-
(1985)
Radiology
, vol.155
, pp. 531
-
-
Cardella, J.F.1
Young, A.T.2
Hunter, D.W.3
Castaneda-Zuniga, W.R.4
Amplatz, K.5
-
8
-
-
0029064627
-
CT-guided automated needle biopsy of the chest
-
Haramati LB. CT-guided automated needle biopsy of the chest. AJR 1995; 165:53-55.
-
(1995)
AJR
, vol.165
, pp. 53-55
-
-
Haramati, L.B.1
-
9
-
-
0030051348
-
Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: Results in 122 patients
-
Klein JS, Salmon G, Stewart EA. Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients. Radiology 1996; 198:715-720.
-
(1996)
Radiology
, vol.198
, pp. 715-720
-
-
Klein, J.S.1
Salmon, G.2
Stewart, E.A.3
-
10
-
-
0030809511
-
Routine addition of an automated biopsy device to fine-needle aspiration of the lung: A prospective assessment
-
Boiselle PM, Shepard JAO, Mark EJ, et al. Routine addition of an automated biopsy device to fine-needle aspiration of the lung: a prospective assessment. AJR 1997; 169: 661-666.
-
(1997)
AJR
, vol.169
, pp. 661-666
-
-
Boiselle, P.M.1
Shepard, J.A.O.2
Mark, E.J.3
-
11
-
-
0031881698
-
CT-guided biopsy of pulmonary nodules less than 3 cm: Usefulness of the spring-operated core biopsy needle and frozen-section pathologic diagnosis
-
Hayashi N, Sakai T, Kitagawa M, et al. CT-guided biopsy of pulmonary nodules less than 3 cm: usefulness of the spring-operated core biopsy needle and frozen-section pathologic diagnosis. AJR 1998; 170: 329-331.
-
(1998)
AJR
, vol.170
, pp. 329-331
-
-
Hayashi, N.1
Sakai, T.2
Kitagawa, M.3
-
12
-
-
0031866908
-
Intrapulmonary lesions: Percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle
-
Lucidarme O, Howarth N, Finet JF, Grenier PA. Intrapulmonary lesions: percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle. Radiology 1998; 207:759-765.
-
(1998)
Radiology
, vol.207
, pp. 759-765
-
-
Lucidarme, O.1
Howarth, N.2
Finet, J.F.3
Grenier, P.A.4
|