Volumn 23, Issue 4 I, 2000, Pages 427-433

Efficacy and safety of bipolar sensing with high atrial sensitivity in dual chamber pacemakers

Author keywords

Atrial sensing; Automatic mode switch; Bipolar electrodes; Dual chamber pacing

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; ATRIOVENTRICULAR BLOCK; CLINICAL ARTICLE; ELECTROCARDIOGRAPHY; ELECTRODE; FEMALE; FOLLOW UP; HEART ATRIUM; HEART MUSCLE REFRACTORY PERIOD; HOLTER MONITORING; HUMAN; MALE; PERFORMANCE; SINUS ARRHYTHMIA; TELEMETRY; TREADMILL EXERCISE;

EID: 0034050105     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2000.tb00822.x     Document Type: Article
Times cited : (13)

References (25)
  • 1
    • 0023719996 scopus 로고
    • Clinical and hemodynamic comparison of VVT versus DDD pacing in patients with DDD pacemakers
    • Rediker DE, Eagle KA, Homma S, et al. Clinical and hemodynamic comparison of VVT versus DDD pacing in patients with DDD pacemakers. Am J Cardiol 1988; 61:323-329.
    • (1988) Am J Cardiol , vol.61 , pp. 323-329
    • Rediker, D.E.1    Eagle, K.A.2    Homma, S.3
  • 2
    • 0028923632 scopus 로고
    • Cardiac output in single-lead VDD-pacing versus rate-matched VV1R pacing
    • Nowak B, Voigtlaender T, Himmrich E, et al. Cardiac output in single-lead VDD-pacing versus rate-matched VV1R pacing. Am J Cardiol 1995; 75:904-907.
    • (1995) Am J Cardiol , vol.75 , pp. 904-907
    • Nowak, B.1    Voigtlaender, T.2    Himmrich, E.3
  • 3
    • 0026577156 scopus 로고
    • Longevity in patients with high degree atrioventricular block paced in the atrial synchronous or the fixed rate ventricular inhibited mode
    • Linde-Edelstam C, Gullberg B, Norlander R, et al. Longevity in patients with high degree atrioventricular block paced in the atrial synchronous or the fixed rate ventricular inhibited mode. PACE 1992; 15:304-313.
    • (1992) PACE , vol.15 , pp. 304-313
    • Linde-Edelstam, C.1    Gullberg, B.2    Norlander, R.3
  • 4
    • 0028036836 scopus 로고
    • Prospective randomised trial of atrial versus ventricular pacing in sick-sinus syndrome
    • Andersen HR, Thuesen L, Bagger JP, et al. Prospective randomised trial of atrial versus ventricular pacing in sick-sinus syndrome. Lancet 1994; 344:1523-1528.
    • (1994) Lancet , vol.344 , pp. 1523-1528
    • Andersen, H.R.1    Thuesen, L.2    Bagger, J.P.3
  • 5
    • 0023628403 scopus 로고
    • Utility of ambulatory electrocardiography in detecting pacemaker dysfunction in the early postimplantation period
    • Janosik DL, Redd RM. Buckingham TA, et al. Utility of ambulatory electrocardiography in detecting pacemaker dysfunction in the early postimplantation period. Am J Cardiol 1987; 60:1030-1035.
    • (1987) Am J Cardiol , vol.60 , pp. 1030-1035
    • Janosik, D.L.1    Redd, R.M.2    Buckingham, T.A.3
  • 6
    • 0343671953 scopus 로고
    • Assessment of transient pacemaker dysfunction and spontaneous arrhythmias in patients with dual chamber pacemakers - A Holter monitoring study
    • Drandes A, Brudna C, Potratz J, et al. Assessment of transient pacemaker dysfunction and spontaneous arrhythmias in patients with dual chamber pacemakers - A Holter monitoring study. Herzschr Elektrophys 1995; 6:47-58.
    • (1995) Herzschr Elektrophys , vol.6 , pp. 47-58
    • Drandes, A.1    Brudna, C.2    Potratz, J.3
  • 7
    • 0020619289 scopus 로고
    • Long-term comparison of unipolar and bipolar pacing and sensing, using a new multiprogrammable pacemaker system
    • Breivik K, Ohm OJ, Engedal H. Long-term comparison of unipolar and bipolar pacing and sensing, using a new multiprogrammable pacemaker system. PACE 1983; 6:592-600.
    • (1983) PACE , vol.6 , pp. 592-600
    • Breivik, K.1    Ohm, O.J.2    Engedal, H.3
  • 8
    • 0031877749 scopus 로고    scopus 로고
    • Should unipolar leads be implanted in the atrium? A Holter-electrocardiographic comparison of threshold-adapted unipolar and high-sensitive bipolar sensing
    • Wiegand UKH, Schier H, Bode F, et al. Should unipolar leads be implanted in the atrium? A Holter-electrocardiographic comparison of threshold-adapted unipolar and high-sensitive bipolar sensing. PACE 1998; 21:1601-1608.
    • (1998) PACE , vol.21 , pp. 1601-1608
    • Wiegand, U.K.H.1    Schier, H.2    Bode, F.3
  • 9
    • 0342366766 scopus 로고    scopus 로고
    • Pacemaker sensing: Modern practice and its clinical significance
    • Potratz J, Wiegand U. Pacemaker sensing: Modern practice and its clinical significance. Herzschr Elektrophysiol 1996; 7:206-210.
    • (1996) Herzschr Elektrophysiol , vol.7 , pp. 206-210
    • Potratz, J.1    Wiegand, U.2
  • 10
    • 0017706910 scopus 로고
    • A comparison of unipolar and bipolar electrograms for cardiac pacemaker sensing
    • DeCaprio V, Hurzeler P, Furman S. A comparison of unipolar and bipolar electrograms for cardiac pacemaker sensing. Circulation 1977; 56:750-755.
    • (1977) Circulation , vol.56 , pp. 750-755
    • DeCaprio, V.1    Hurzeler, P.2    Furman, S.3
  • 11
    • 0025670098 scopus 로고
    • Physical determinants of the endocardial P-wave
    • Shandling AH, Florio J, Castellanet MJ, et al. Physical determinants of the endocardial P-wave. PACE 1990; 13:1585-1589.
    • (1990) PACE , vol.13 , pp. 1585-1589
    • Shandling, A.H.1    Florio, J.2    Castellanet, M.J.3
  • 12
    • 0026321530 scopus 로고
    • The effect of exercise on the atrial electrogram voltage in young patients
    • Ross BA, Zeigler VA, Zinner A, et al. The effect of exercise on the atrial electrogram voltage in young patients. PACE 1991; 14: 2092-2097.
    • (1991) PACE , vol.14 , pp. 2092-2097
    • Ross, B.A.1    Zeigler, V.A.2    Zinner, A.3
  • 13
    • 0024503157 scopus 로고
    • The effects of drugs and lead maturation on atrial electrograms during sinus rhythm and atrial fibrillation
    • Bump TE, Ripley KL, Guezennec A, et al. The effects of drugs and lead maturation on atrial electrograms during sinus rhythm and atrial fibrillation. Am Heart J 1989; 117:577-584.
    • (1989) Am Heart J , vol.117 , pp. 577-584
    • Bump, T.E.1    Ripley, K.L.2    Guezennec, A.3
  • 14
    • 0029011296 scopus 로고
    • Atrial sensing by a new VDD pacemaker
    • Voigtlander T, Nowak B, Treese N, et al. Atrial sensing by a new VDD pacemaker. Z Kardiol 1995; 84:459-167.
    • (1995) Z Kardiol , vol.84 , pp. 459-1167
    • Voigtlander, T.1    Nowak, B.2    Treese, N.3
  • 15
    • 0031064797 scopus 로고    scopus 로고
    • Atrial sensing and AV-synchrony in single-lead VDD-pacemakers. Is the occurrence of atrial undersensing predictable?
    • Wiegand UKH, Schneider R, Bode F, et al. Atrial sensing and AV-synchrony in single-lead VDD-pacemakers. Is the occurrence of atrial undersensing predictable? Z Kardiol 1997; 86:95-104.
    • (1997) Z Kardiol , vol.86 , pp. 95-104
    • Wiegand, U.K.H.1    Schneider, R.2    Bode, F.3
  • 16
    • 0022362302 scopus 로고
    • Amplitude of atrial electrical activity during sinus rhythm and during atrial flutter/fibrillation
    • Kerr CE, Mason MA. Amplitude of atrial electrical activity during sinus rhythm and during atrial flutter/fibrillation. PACE 1985; 8:348-355.
    • (1985) PACE , vol.8 , pp. 348-355
    • Kerr, C.E.1    Mason, M.A.2
  • 17
    • 0030021807 scopus 로고    scopus 로고
    • Comparison of bipolar atrial potential amplitude in sinus rhythm, atrial fibrillation, and atrial flutter
    • Wood MA, Moskovlevic P, Stambler BS, et al. Comparison of bipolar atrial potential amplitude in sinus rhythm, atrial fibrillation, and atrial flutter. PACE 1996; 19:150-156.
    • (1996) PACE , vol.19 , pp. 150-156
    • Wood, M.A.1    Moskovlevic, P.2    Stambler, B.S.3
  • 18
    • 0028104147 scopus 로고
    • The "automatic mode switch" function in successive generations of minute ventilation sensing dual chamber rate responsive pacemakers
    • Provenier F, Jordaens L, Verstraeten T, et al. The "automatic mode switch" function in successive generations of minute ventilation sensing dual chamber rate responsive pacemakers. PACE 1994; 17:1913-1919.
    • (1994) PACE , vol.17 , pp. 1913-1919
    • Provenier, F.1    Jordaens, L.2    Verstraeten, T.3
  • 19
    • 0028019301 scopus 로고
    • Initial experience with mode switching in a dual sensor, dual chamber pacemaker in patients with paroxysmal atrial tachyarrhythmias
    • den Dulk K, Dijkman B, Pieterse M, et al. Initial experience with mode switching in a dual sensor, dual chamber pacemaker in patients with paroxysmal atrial tachyarrhythmias. PACE 1994; 17:1900-1907.
    • (1994) PACE , vol.17 , pp. 1900-1907
    • Den Dulk, K.1    Dijkman, B.2    Pieterse, M.3
  • 20
    • 0028114538 scopus 로고
    • Initial experience with a new algorithm for automatic mode switching from DDDR to DDIR mode
    • Ovysyshcher IE, Katz A, Bondy C. Initial experience with a new algorithm for automatic mode switching from DDDR to DDIR mode. PACE 1994; 17:1908-1912.
    • (1994) PACE , vol.17 , pp. 1908-1912
    • Ovysyshcher, I.E.1    Katz, A.2    Bondy, C.3
  • 21
    • 10544219603 scopus 로고    scopus 로고
    • Reliability of a new algorithm for automatic mode switching from DDDR to DDIR pacing mode in sinus node disease patients witb chronotropic incompetence and recurrent paroxysmal atrial fibrillation
    • Ricci R, Puglisi A, Azzolini P, et al. Reliability of a new algorithm for automatic mode switching from DDDR to DDIR pacing mode in sinus node disease patients witb chronotropic incompetence and recurrent paroxysmal atrial fibrillation. PACE 1996; 19:1719-1723.
    • (1996) PACE , vol.19 , pp. 1719-1723
    • Ricci, R.1    Puglisi, A.2    Azzolini, P.3
  • 22
    • 0029958324 scopus 로고    scopus 로고
    • Effect of varying atrial sensitivity, AV-interval and detection algorithm on automatic mode switching
    • Palma EC, Kedarnath V, Vankawalla V, et al. Effect of varying atrial sensitivity, AV-interval and detection algorithm on automatic mode switching. PACE 1996; 19:1734-1739.
    • (1996) PACE , vol.19 , pp. 1734-1739
    • Palma, E.C.1    Kedarnath, V.2    Vankawalla, V.3
  • 23
    • 0029909332 scopus 로고    scopus 로고
    • Mode-switch despite undersensing of atrial fibrillation in ddd pacing
    • Bonnet JL, Brusseau E, Limosin M, et al. Mode-switch despite undersensing of atrial fibrillation in DDD pacing. PACE 1996; 19:1724-1728.
    • (1996) PACE , vol.19 , pp. 1724-1728
    • Bonnet, J.L.1    Brusseau, E.2    Limosin, M.3
  • 24
    • 0025893309 scopus 로고
    • Loss of atrial signal detection with increasing sensitivity setting: A software problem and its practical solution
    • Frohlig G, Schwerdt H, Berg M, et al. Loss of atrial signal detection with increasing sensitivity setting: A software problem and its practical solution. PACE 1991; 14:522-528.
    • (1991) PACE , vol.14 , pp. 522-528
    • Frohlig, G.1    Schwerdt, H.2    Berg, M.3
  • 25
    • 0029837340 scopus 로고    scopus 로고
    • Is there a risk for interaction between mobile phones and single-lead VDD pacemakers?
    • Nowak B, Rosocha S, Zollerhoff C, et al. Is there a risk for interaction between mobile phones and single-lead VDD pacemakers? PACE 1996; 19:1447-1450.
    • (1996) PACE , vol.19 , pp. 1447-1450
    • Nowak, B.1    Rosocha, S.2    Zollerhoff, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.