메뉴 건너뛰기




Volumn 44, Issue 6, 2000, Pages 743-748

Changes in rapidly extracted auditory evoked potentials during tracheal intubation

Author keywords

Anesthesia; Auditory evoked potentials; Depth of anesthesia; Hypnotic level

Indexed keywords

ADULT; AGED; ANESTHESIA LEVEL; ARTICLE; CLINICAL ARTICLE; ENDOTRACHEAL INTUBATION; EVOKED AUDITORY RESPONSE; FEMALE; HUMAN; NEUROMUSCULAR BLOCKING; PRIORITY JOURNAL; RESPONSE TIME;

EID: 0034044164     PISSN: 00015172     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1399-6576.2000.440614.x     Document Type: Article
Times cited : (33)

References (28)
  • 1
    • 0027715634 scopus 로고
    • Evaluating depth of anesthesia: Review of methods
    • 1. Thornton C, Jones JG. Evaluating depth of anesthesia: Review of methods. Int Anesthesiol Clin 1993: 31: 67-88.
    • (1993) Int Anesthesiol Clin , vol.31 , pp. 67-88
    • Thornton, C.1    Jones, J.G.2
  • 2
    • 0000352245 scopus 로고
    • Effect of the electro-encephalogram of certain drugs which influence nervous activity
    • 2. Gibbs GA, Gibbs EL, Lennox WG. Effect of the electro-encephalogram of certain drugs which influence nervous activity. Arch Int Med 1937: 60: 154-166.
    • (1937) Arch Int Med , vol.60 , pp. 154-166
    • Gibbs, G.A.1    Gibbs, E.L.2    Lennox, W.G.3
  • 3
    • 0000106726 scopus 로고
    • The classification and significance of electroencephalographic patterns produced by nitrous oxide-ether anesthesia during surgical operation
    • 3. Courtin RF, Bickford RG, Faulconer AJR. The classification and significance of electroencephalographic patterns produced by nitrous oxide-ether anesthesia during surgical operation. Proc Staff Meetings Mayo Clinic 1950: 25: 197-206.
    • (1950) Proc Staff Meetings Mayo Clinic , vol.25 , pp. 197-206
    • Courtin, R.F.1    Bickford, R.G.2    Faulconer, A.J.R.3
  • 4
    • 0025978850 scopus 로고
    • Evoked potentials in anaesthesia
    • 4. Thornton C. Evoked potentials in anaesthesia. Eur J Anaesthesiol 1991: 8: 89-107.
    • (1991) Eur J Anaesthesiol , vol.8 , pp. 89-107
    • Thornton, C.1
  • 7
    • 0014802929 scopus 로고
    • Volume-conducted potentials in response to auditory stimuli as detected by averaging in the cat
    • 7. Jewett DL. Volume-conducted potentials in response to auditory stimuli as detected by averaging in the cat. Proc San Diego Biomed Symp 1970: 28: 609-618.
    • (1970) Proc San Diego Biomed Symp , vol.28 , pp. 609-618
    • Jewett, D.L.1
  • 8
    • 0015274835 scopus 로고
    • Sources of averaged neural responses recorded in animal and human subjects during cochlear audiometry (electrocochleogram)
    • 8. Lev A, Sohmer H. Sources of averaged neural responses recorded in animal and human subjects during cochlear audiometry (electrocochleogram). Arch Klin Exp Ohren Nasen Kehlkopfheil 1972: 201: 79-90.
    • (1972) Arch Klin Exp Ohren Nasen Kehlkopfheil , vol.201 , pp. 79-90
    • Lev, A.1    Sohmer, H.2
  • 9
    • 0016734702 scopus 로고
    • Far-field acoustic response: Origins in the cat
    • 9. Buchwald JS, Huang CH. Far-field acoustic response: origins in the cat. Science 1975: 189: 382-384.
    • (1975) Science , vol.189 , pp. 382-384
    • Buchwald, J.S.1    Huang, C.H.2
  • 10
    • 0013673564 scopus 로고
    • Detection and localization of brainstem lesions with auditory brainstem potentials
    • Barber C, ed. Lancaster, England: MTP Press Ltd
    • 10. Maurer K, Leitner H, Schafer E. Detection and localization of brainstem lesions with auditory brainstem potentials. In: Barber C, ed. Evoked potentials. Lancaster, England: MTP Press Ltd, 1980: 391-398.
    • (1980) Evoked Potentials , pp. 391-398
    • Maurer, K.1    Leitner, H.2    Schafer, E.3
  • 11
    • 0019173924 scopus 로고
    • Evidence for a primary cortical origin of a middle latency auditory evoked potential in cats
    • 11. Kaga F, Hink RF, Sinoda Y, Suzuki J. Evidence for a primary cortical origin of a middle latency auditory evoked potential in cats. Electroencephalogr Clin Neurophysiol 1980: 50: 254-266.
    • (1980) Electroencephalogr Clin Neurophysiol , vol.50 , pp. 254-266
    • Kaga, F.1    Hink, R.F.2    Sinoda, Y.3    Suzuki, J.4
  • 12
    • 0019366470 scopus 로고
    • Middle and long latency auditory evoked responses recorded from the vertex of normal and chronically lesioned cats
    • 12. Buchwald JS, Hinman C, Norman RJ, Huang CM, Brown KA. Middle and long latency auditory evoked responses recorded from the vertex of normal and chronically lesioned cats. Brain Res 1981: 205: 91-109.
    • (1981) Brain Res , vol.205 , pp. 91-109
    • Buchwald, J.S.1    Hinman, C.2    Norman, R.J.3    Huang, C.M.4    Brown, K.A.5
  • 13
    • 0023148993 scopus 로고
    • Effects of cortical lesions on middle latency auditory evoked responses (MLR)
    • 13. Kileny P, Paccioretti D, Wilson AF. Effects of cortical lesions on middle latency auditory evoked responses (MLR). Electroencephalogr Clin Neurophysiol 1987: 66: 108-120.
    • (1987) Electroencephalogr Clin Neurophysiol , vol.66 , pp. 108-120
    • Kileny, P.1    Paccioretti, D.2    Wilson, A.F.3
  • 14
    • 0023102032 scopus 로고
    • Generators of middle- and long-latency auditory evoked potentials: Implications from studies of patients with bitemporal lesions
    • 14. Woods DL, Clayworth CC, Knight RT, Simpson GV, Naeser MA. Generators of middle-and long-latency auditory evoked potentials: implications from studies of patients with bitemporal lesions. Electroencephalogr Clin Neurophysiol 1987: 68: 132-148.
    • (1987) Electroencephalogr Clin Neurophysiol , vol.68 , pp. 132-148
    • Woods, D.L.1    Clayworth, C.C.2    Knight, R.T.3    Simpson, G.V.4    Naeser, M.A.5
  • 16
    • 0029826396 scopus 로고    scopus 로고
    • Auto regressive modeling with exogenous input of auditory evoked potentials to produce an on-line depth of anaesthesia index
    • 16. Jensen EW, Lindholm P, Henneberg S. Auto regressive modeling with exogenous input of auditory evoked potentials to produce an on-line depth of anaesthesia index. Methods Inf Med 1996: 35: 256-260.
    • (1996) Methods Inf Med , vol.35 , pp. 256-260
    • Jensen, E.W.1    Lindholm, P.2    Henneberg, S.3
  • 17
    • 0029945017 scopus 로고    scopus 로고
    • A measure of association for assessing prediction accuracy that is a generalization of non-parametric ROC area
    • 17. Smith WD, Dutton RC, Smith NT. A measure of association for assessing prediction accuracy that is a generalization of non-parametric ROC area. Stat Med 1996: 15: 1199-1215.
    • (1996) Stat Med , vol.15 , pp. 1199-1215
    • Smith, W.D.1    Dutton, R.C.2    Smith, N.T.3
  • 18
    • 0031415928 scopus 로고    scopus 로고
    • On-line analysis of averaged AEP, autoregressive (ARX) modeled AEP and spectral edge frequency of EEG for monitoring depth of anaesthesia
    • 18. Capitanio L, Jensen EW, Filligoi GC et al. On-line analysis of averaged AEP, autoregressive (ARX) modeled AEP and spectral edge frequency of EEG for monitoring depth of anaesthesia. Methods Inf Med 1997: 36: 311-314.
    • (1997) Methods Inf Med , vol.36 , pp. 311-314
    • Capitanio, L.1    Jensen, E.W.2    Filligoi, G.C.3
  • 19
    • 0024078066 scopus 로고
    • A parametric method of identification of single-trial event-related potentials in the brain
    • 19. Cerutti S, Chiarenza G, Liberati D, Mascellani P, Pavesi G. A parametric method of identification of single-trial event-related potentials in the brain. IEEE Trans Biomed Eng 1988: 35: 701-711.
    • (1988) IEEE Trans Biomed Eng , vol.35 , pp. 701-711
    • Cerutti, S.1    Chiarenza, G.2    Liberati, D.3    Mascellani, P.4    Pavesi, G.5
  • 20
    • 0023223798 scopus 로고
    • Single sweep analysis of visual evoked potentials through a model of parametric identification
    • 20. Cerutti S, Baselli G, Liberati D. Single sweep analysis of visual evoked potentials through a model of parametric identification. Biol Cybern 1987: 56: 111-120.
    • (1987) Biol Cybern , vol.56 , pp. 111-120
    • Cerutti, S.1    Baselli, G.2    Liberati, D.3
  • 21
    • 0024691812 scopus 로고
    • The implementation of an autoregressive model with exogenous input in a single sweep visual evoked potential analysis
    • 21. Liberatti D, Cerutti S. The implementation of an autoregressive model with exogenous input in a single sweep visual evoked potential analysis. J Biomed Eng 1989: 11: 285-292.
    • (1989) J Biomed Eng , vol.11 , pp. 285-292
    • Liberatti, D.1    Cerutti, S.2
  • 22
    • 0030662399 scopus 로고    scopus 로고
    • Auditory evoked potential index: A quantitative measure of changes in auditory evoked potentials during general anaesthesia
    • 22. Mantzaridis H, Kenny GN. Auditory evoked potential index: a quantitative measure of changes in auditory evoked potentials during general anaesthesia. Anaesthesia 1997: 52: 1030-1036.
    • (1997) Anaesthesia , vol.52 , pp. 1030-1036
    • Mantzaridis, H.1    Kenny, G.N.2
  • 23
    • 0031974636 scopus 로고    scopus 로고
    • Analysis of the EEG bispectrum, auditory evoked potential and the EEG power spectrum during repeated transitions from consciousness to unconsciousness
    • 23. Gajraj RJ, Doi M, Mantzaridis H, Kenny GN. Analysis of the EEG bispectrum, auditory evoked potential and the EEG power spectrum during repeated transitions from consciousness to unconsciousness. Br J Anaesth 1998: 80: 46-52.
    • (1998) Br J Anaesth , vol.80 , pp. 46-52
    • Gajraj, R.J.1    Doi, M.2    Mantzaridis, H.3    Kenny, G.N.4
  • 24
    • 0032895807 scopus 로고    scopus 로고
    • Identification of causal relations between haemodynamic parameters, auditory evoked potentials and isoflurane by means of fuzzy logic
    • 24. Jensen EW, Nebot A, Caminal P, Henneberg SW. Identification of causal relations between haemodynamic parameters, auditory evoked potentials and isoflurane by means of fuzzy logic. Br J Anaesth 1999: 82: 25-32.
    • (1999) Br J Anaesth , vol.82 , pp. 25-32
    • Jensen, E.W.1    Nebot, A.2    Caminal, P.3    Henneberg, S.W.4
  • 26
    • 0002975907 scopus 로고    scopus 로고
    • Assessing depth of anaesthesia by auditory evoked potentials during continuous propofol infusion
    • 26. Litvan H, Jensen EW, Maestre M, Galan J, Campos JM, Villar JM. Assessing depth of anaesthesia by auditory evoked potentials during continuous propofol infusion. Br J Anaesth 1999: 82 (Suppl): A20.
    • (1999) Br J Anaesth , vol.82 , Issue.SUPPL.
    • Litvan, H.1    Jensen, E.W.2    Maestre, M.3    Galan, J.4    Campos, J.M.5    Villar, J.M.6
  • 27
    • 0031052593 scopus 로고    scopus 로고
    • Relationship between calculated blood concentration of propofol and electrophysiological variables during emergence from anaesthesia: Comparison of bispectral index, spectral edge frequency, median frequency and auditory evoked potential index
    • 27. Doi M, Gajraj RJ, Mantzaridis H, Kenny GN. Relationship between calculated blood concentration of propofol and electrophysiological variables during emergence from anaesthesia: comparison of bispectral index, spectral edge frequency, median frequency and auditory evoked potential index. Br J Anaesth 1997: 78: 180-184.
    • (1997) Br J Anaesth , vol.78 , pp. 180-184
    • Doi, M.1    Gajraj, R.J.2    Mantzaridis, H.3    Kenny, G.N.4
  • 28
    • 0032932122 scopus 로고    scopus 로고
    • Prediction of movement at laryngeal mask airway insertion: Comparison of auditory evoked potential index, bispectral index, spectral edge frequency and median frequency
    • 28. Doi M, Gajraj RJ, Mantzaridis H, Kenny GN. Prediction of movement at laryngeal mask airway insertion: comparison of auditory evoked potential index, bispectral index, spectral edge frequency and median frequency. Br J Anaesth 1999: 82: 203-207.
    • (1999) Br J Anaesth , vol.82 , pp. 203-207
    • Doi, M.1    Gajraj, R.J.2    Mantzaridis, H.3    Kenny, G.N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.