메뉴 건너뛰기




Volumn 26, Issue 3, 2000, Pages 413-418

A new algorithm for off-line automated emboli detection based on the pseudo-wigner power distribution and the dual gate TCD technique

Author keywords

Embolism; FFT; Pseudo Wigner function; Transcranial Doppler

Indexed keywords

ALGORITHMS; DOPPLER EFFECT; FAST FOURIER TRANSFORMS; MEDICAL IMAGING; SIGNAL TO NOISE RATIO; ULTRASONIC VELOCITY MEASUREMENT;

EID: 0034035226     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(99)00168-4     Document Type: Article
Times cited : (19)

References (17)
  • 1
    • 0343739081 scopus 로고    scopus 로고
    • Differentiation between gaseous and solid microemboli using multifrequency Doppler
    • (Abstr.)
    • Brucher R., Russell D. Differentiation between gaseous and solid microemboli using multifrequency Doppler. (Abstr.) Eur J Ultrasound. 5:1997;S40.
    • (1997) Eur J Ultrasound , vol.5 , pp. 40
    • Brucher, R.1    Russell, D.2
  • 2
    • 0030890451 scopus 로고    scopus 로고
    • Bigated transcranial Doppler for the detection of clinically silent circulating emboli in normal persons and patients with prosthetic heart valves
    • Droste D.W., Hagedorn G., Nötzold A., Siemens H.J., Sievers H.H., Kaps M. Bigated transcranial Doppler for the detection of clinically silent circulating emboli in normal persons and patients with prosthetic heart valves. Stroke. 28:1997;588-592.
    • (1997) Stroke , vol.28 , pp. 588-592
    • Droste, D.W.1    Hagedorn, G.2    Nötzold, A.3    Siemens, H.J.4    Sievers, H.H.5    Kaps, M.6
  • 4
    • 0028236512 scopus 로고
    • Extracting instantaneous mean frequency information from Doppler signals using the Wigner distribution function
    • Fan L., Evans D.H. Extracting instantaneous mean frequency information from Doppler signals using the Wigner distribution function. Ultrasound Med Biol. 20:1994;429-443.
    • (1994) Ultrasound Med Biol , vol.20 , pp. 429-443
    • Fan, L.1    Evans, D.H.2
  • 5
    • 0028298966 scopus 로고
    • A real-time and fine resolution analyser used to estimate the instantaneous energy distribution of Doppler signals
    • Fan L., Evans D.H. A real-time and fine resolution analyser used to estimate the instantaneous energy distribution of Doppler signals. Ultrasound Med Biol. 20:1994;445-454.
    • (1994) Ultrasound Med Biol , vol.20 , pp. 445-454
    • Fan, L.1    Evans, D.H.2
  • 6
    • 0029961735 scopus 로고    scopus 로고
    • A novel technique for identification and Doppler microembolic signals based on the coincidence method; In vitro and in vivo evaluation
    • Georgiadis D., Goeke J., Hill M., König M., Nabovi D.G., Stögbauer F., Zunker P., Ringelstein E.B. A novel technique for identification and Doppler microembolic signals based on the coincidence method; in vitro and in vivo evaluation. Stroke. 27:1996;683-686.
    • (1996) Stroke , vol.27 , pp. 683-686
    • Georgiadis, D.1    Goeke, J.2    Hill, M.3    König, M.4    Nabovi, D.G.5    Stögbauer, F.6    Zunker, P.7    Ringelstein, E.B.8
  • 7
    • 0031984358 scopus 로고    scopus 로고
    • Automated intraoperative detection of Doppler microembolic signals using the bigate approach
    • Georgiadis D., Wenzel A., Zerkowski H.R., Zierz S., Lindner A. Automated intraoperative detection of Doppler microembolic signals using the bigate approach. Stroke. 29:1998;137-139.
    • (1998) Stroke , vol.29 , pp. 137-139
    • Georgiadis, D.1    Wenzel, A.2    Zerkowski, H.R.3    Zierz, S.4    Lindner, A.5
  • 8
    • 0031881002 scopus 로고    scopus 로고
    • Preliminary report of detecting microembolic signals in transcranial Doppler time series with nonlinear forecasting
    • Keunen R.W.M., Stam C.J., Tavy D.L.J., Mess W.H., Titulaer B.M., Ackerstaff R.G.A. Preliminary report of detecting microembolic signals in transcranial Doppler time series with nonlinear forecasting. Stroke. 29:1998;1638-1643.
    • (1998) Stroke , vol.29 , pp. 1638-1643
    • Keunen, R.W.M.1    Stam, C.J.2    Tavy, D.L.J.3    Mess, W.H.4    Titulaer, B.M.5    Ackerstaff, R.G.A.6
  • 9
    • 0001688924 scopus 로고    scopus 로고
    • Discrimination and characterization of emboli: Old and new aspects
    • J. Klingelhöfer, E. Bartels, & E.B. Ringelstein. Amsterdam: Elsevier
    • Mess W.H., Titulaer B.M., Ackerstaff R.G.A. Discrimination and characterization of emboli old and new aspects . Klingelhöfer J., Bartels E., Ringelstein E.B. New trends in cerebral hemodynamics and neurosonology. 1997;355-363 Elsevier, Amsterdam.
    • (1997) New Trends in Cerebral Hemodynamics and Neurosonology , pp. 355-363
    • Mess, W.H.1    Titulaer, B.M.2    Ackerstaff, R.G.A.3
  • 10
    • 0032909977 scopus 로고    scopus 로고
    • Middle cerebral artery anatomy and characteristics of embolic signals - A dual gate computer simulation study
    • Mess WH, Titulaer BM, Ackerstaff RGA. Middle cerebral artery anatomy and characteristics of embolic signals - a dual gate computer simulation study. Ultrasound Med Biol 1999;25:531-539.
    • (1999) Ultrasound Med Biol , vol.25 , pp. 531-539
    • Mess, W.H.1    Titulaer, B.M.2    Ackerstaff, R.G.A.3
  • 11
    • 0343851103 scopus 로고    scopus 로고
    • Low frequency annular transducers for detecting and characterizing microemboli in cardiopulmonary bypass (CPB) flow circuits with the embolus to blood power ratio (EBR)
    • (Abstr.)
    • Moehring M.A., Spencer M.P., Radford R.L., McDaniel M.D., Mattson G.A. Low frequency annular transducers for detecting and characterizing microemboli in cardiopulmonary bypass (CPB) flow circuits with the embolus to blood power ratio (EBR). (Abstr.) Eur J Ultrasound. 5:1997;S41.
    • (1997) Eur J Ultrasound , vol.5 , pp. 41
    • Moehring, M.A.1    Spencer, M.P.2    Radford, R.L.3    McDaniel, M.D.4    Mattson, G.A.5
  • 12
    • 0029795365 scopus 로고    scopus 로고
    • Multigated Doppler ultrasound in the detection of emboli in a flow model and embolic signals in patients
    • Molloy J., Markus H.S. Multigated Doppler ultrasound in the detection of emboli in a flow model and embolic signals in patients. Stroke. 27:1996;1548-1552.
    • (1996) Stroke , vol.27 , pp. 1548-1552
    • Molloy, J.1    Markus, H.S.2
  • 13
    • 0032033176 scopus 로고    scopus 로고
    • The narrow band hypothesis: An interesting approach for high-intensity transient signals (HITS) detection
    • Roy E., Abraham P., Montrésor S., Baudry M., Saumet J.L. The narrow band hypothesis an interesting approach for high-intensity transient signals (HITS) detection . Ultrasound Med Biol. 24:1998;375-382.
    • (1998) Ultrasound Med Biol , vol.24 , pp. 375-382
    • Roy, E.1    Abraham, P.2    Montrésor, S.3    Baudry, M.4    Saumet, J.L.5
  • 14
    • 0030459206 scopus 로고    scopus 로고
    • Differentiation between emboli and artefacts using dual-gated transcranial Doppler ultrasound
    • Smith J.L., Evans D.H., Fan L., Bell P.R.F., Naylor A.R. Differentiation between emboli and artefacts using dual-gated transcranial Doppler ultrasound. Ultrasound Med Biol. 22:1997;1031-1036.
    • (1997) Ultrasound Med Biol , vol.22 , pp. 1031-1036
    • Smith, J.L.1    Evans, D.H.2    Fan, L.3    Bell, P.R.F.4    Naylor, A.R.5
  • 16
    • 0031046934 scopus 로고    scopus 로고
    • Signals from dual gated TCD systems: Curious observations and possible explanations
    • Smith J.L., Evans D.H., Naylor A.R. Signals from dual gated TCD systems curious observations and possible explanations . Ultrasound Med Biol. 23:1997;15-24.
    • (1997) Ultrasound Med Biol , vol.23 , pp. 15-24
    • Smith, J.L.1    Evans, D.H.2    Naylor, A.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.