메뉴 건너뛰기




Volumn 23, Issue 1, 1997, Pages 15-24

Signals from dual gated TCD systems: Curious observations and possible explanations

Author keywords

Doppler shift velocity; Embolism; Transcranial Doppler ultrasonography

Indexed keywords

BLOOD VESSELS; BRAIN; CALCULATIONS; DOPPLER EFFECT; GEOMETRY; HEMODYNAMICS; VELOCITY;

EID: 0031046934     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(96)00188-3     Document Type: Article
Times cited : (15)

References (7)
  • 1
    • 0024808965 scopus 로고
    • Spatial resolution of transcranial pulsed doppler technique in vitro evaluation of the sensitivity distribution of the sample volume
    • Arnolds BJ, Kunz D, von Reutern G-M. Spatial resolution of transcranial pulsed Doppler technique in vitro evaluation of the sensitivity distribution of the sample volume. Ultrasound Med Biol 1989;15:729-735.
    • (1989) Ultrasound Med Biol , vol.15 , pp. 729-735
    • Arnolds, B.J.1    Kunz, D.2    Von Reutern, G.-M.3
  • 2
    • 0028298966 scopus 로고
    • A real-time and fine resolution analyser used to estimate the instantaneous energy distribution of doppler signals
    • Fan L, Evans DH. A real-time and fine resolution analyser used to estimate the instantaneous energy distribution of Doppler signals. Ultrasound Med Biol 1994a;20:445-454.
    • (1994) Ultrasound Med Biol , vol.20 , pp. 445-454
    • Fan, L.1    Evans, D.H.2
  • 3
    • 0028236512 scopus 로고
    • Extracting instantaneous mean frequency information from doppler signals using the wigner distribution function
    • Fan L, Evans DH. Extracting instantaneous mean frequency information from Doppler signals using the Wigner distribution function. Ultrasound Med Biol 1994b;20:429-443.
    • (1994) Ultrasound Med Biol , vol.20 , pp. 429-443
    • Fan, L.1    Evans, D.H.2
  • 4
    • 0029961735 scopus 로고    scopus 로고
    • A novel technique for identification of doppler microembolic signals based on the coincidence method. In vitro and in vivo evaluation
    • Georgiadis D, Goeke J, Hill M, et al. A novel technique for identification of Doppler microembolic signals based on the coincidence method. In vitro and in vivo evaluation. Stroke 1996;27:683-686.
    • (1996) Stroke , vol.27 , pp. 683-686
    • Georgiadis, D.1    Goeke, J.2    Hill, M.3
  • 5
    • 0027756983 scopus 로고
    • Transcranial colour coded sonography as an aid to measurement of blood flow velocity in the basal cerebral arteries
    • Martin PJ, Evans DH, Naylor AR, Bell PRF. Transcranial colour coded sonography as an aid to measurement of blood flow velocity in the basal cerebral arteries. Ultrasound Med Biol 1993;19:711-716.
    • (1993) Ultrasound Med Biol , vol.19 , pp. 711-716
    • Martin, P.J.1    Evans, D.H.2    Naylor, A.R.3    Bell, P.R.F.4
  • 7
    • 0030459206 scopus 로고    scopus 로고
    • Differentiation between emboli and artefacts using dual gated transcranial doppler ultrasound
    • Smith JL, Evans DH, Fan L, Bell PRF, Naylor AR. Differentiation between emboli and artefacts using dual gated transcranial Doppler ultrasound. Ultrasound Med Biol 1996;22:1031-1036.
    • (1996) Ultrasound Med Biol , vol.22 , pp. 1031-1036
    • Smith, J.L.1    Evans, D.H.2    Fan, L.3    Bell, P.R.F.4    Naylor, A.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.