메뉴 건너뛰기




Volumn 59, Issue 2, 2000, Pages 290-300

A histomorphometric observation of flows in cortical bone under dynamic loading

Author keywords

Biomechanics; Bone; Histomorphometry; Interstitial fluid flows

Indexed keywords

FERRITIN;

EID: 0034014336     PISSN: 00262862     EISSN: None     Source Type: Journal    
DOI: 10.1006/mvre.1999.2215     Document Type: Article
Times cited : (22)

References (31)
  • 1
    • 84964162143 scopus 로고
    • Experimental investigation of microcirculation in bone marrow
    • Branemark P. I. Experimental investigation of microcirculation in bone marrow. Angiology. 12:1961;293-306.
    • (1961) Angiology , vol.12 , pp. 293-306
    • Branemark, P.I.1
  • 2
    • 0019436743 scopus 로고
    • The mechanical and biological response of cortical bone to in vivo strain histories
    • S. C. Cowin. Am. Soc. Mech. Eng.
    • Carter D. R., Harris W. H., Vasu R., Caler W. E. The mechanical and biological response of cortical bone to in vivo strain histories. Cowin S. C. Mechanical Properties of Bone. 1981;81-92 Am. Soc. Mech. Eng.
    • (1981) Mechanical Properties of Bone , pp. 81-92
    • Carter, D.R.1    Harris, W.H.2    Vasu, R.3    Caler, W.E.4
  • 3
    • 0014279797 scopus 로고
    • Electromechanical characteristics of bone under physiologic moisture conditions
    • Cochran G. V. B., Pawluk R. J., Bassett C. A. L. Electromechanical characteristics of bone under physiologic moisture conditions. Clin. Orthop. Rel. Res. 58:1968;249-270.
    • (1968) Clin. Orthop. Rel. Res. , vol.58 , pp. 249-270
    • Cochran, G.V.B.1    Pawluk, R.J.2    Bassett, C.A.L.3
  • 4
    • 0015956733 scopus 로고
    • A simplified method for preparation of methyl methacrylate embedding medium for undecalcified bone
    • Difford J. A simplified method for preparation of methyl methacrylate embedding medium for undecalcified bone. Med. Lab. Technol. 31:1974;79-81.
    • (1974) Med. Lab. Technol. , vol.31 , pp. 79-81
    • Difford, J.1
  • 5
    • 0026336596 scopus 로고
    • Fluid Movement in Bone: Theoretical and Experimental
    • Dillaman R. M., Boer R. D., Gay D. M. Fluid Movement in Bone: Theoretical and Experimental. J. Biomech. 24:1991;163-177.
    • (1991) J. Biomech. , vol.24 , pp. 163-177
    • Dillaman, R.M.1    Boer, R.D.2    Gay, D.M.3
  • 6
    • 0020053707 scopus 로고
    • Streaming potential and the electromechanical response of physiological moist bone
    • Gross D., Williams W. S. Streaming potential and the electromechanical response of physiological moist bone. J. Biomech. 15:1982;277-295.
    • (1982) J. Biomech. , vol.15 , pp. 277-295
    • Gross, D.1    Williams, W.S.2
  • 7
    • 0018700041 scopus 로고
    • Electromechanical properties and related models of bone tissues -a review
    • Guzelsu N., Demiray H. Electromechanical properties and related models of bone tissues -a review. Int. J. Engng. Sci. 17:1979;813-851.
    • (1979) Int. J. Engng. Sci. , vol.17 , pp. 813-851
    • Guzelsu, N.1    Demiray, H.2
  • 10
    • 0039220926 scopus 로고
    • Electromechanical effects in bone
    • R. Skalak, & S. Chien. McGraw-Hill
    • Johnson M. W., Katz J. L. Electromechanical effects in bone. Skalak R., Chien S. Handbook of Bioengineering. 1987;3.1-3.11 McGraw-Hill.
    • (1987) Handbook of Bioengineering , pp. 31-311
    • Johnson, M.W.1    Katz, J.L.2
  • 11
    • 0029347488 scopus 로고
    • A theoretical model of circulatory interstitial fluid flow and species transport within porous cortical bone
    • Keanini R. G., Roer R. D., Dillamen R. M. A theoretical model of circulatory interstitial fluid flow and species transport within porous cortical bone. J. Biomech. 28:1995;901-914.
    • (1995) J. Biomech. , vol.28 , pp. 901-914
    • Keanini, R.G.1    Roer, R.D.2    Dillamen, R.M.3
  • 12
    • 0015606843 scopus 로고
    • Comparison of marrow and cortical blood flow by 1251-labeled 4-iodoantipyrine (1-Ap) Washout
    • Kelly P. J. Comparison of marrow and cortical blood flow by 1251-labeled 4-iodoantipyrine (1-Ap) Washout. J. Lab. Clin. Med. 81:1973;497-505.
    • (1973) J. Lab. Clin. Med. , vol.81 , pp. 497-505
    • Kelly, P.J.1
  • 13
    • 0031975298 scopus 로고    scopus 로고
    • In-Vivo tracer transport through the lacuno canalicular system of rat bone in an environment devoid of mechanical loading
    • Knothe-Tate M. L., Niederer P., Knothe U. In-Vivo tracer transport through the lacuno canalicular system of rat bone in an environment devoid of mechanical loading. Bone. 22:1998;107-117.
    • (1998) Bone , vol.22 , pp. 107-117
    • Knothe-Tate, M.L.1    Niederer, P.2    Knothe, U.3
  • 15
    • 0016683563 scopus 로고
    • Bone deformation recorded in vivo from strain gauges attached to the human tibial shaft
    • Lanyon L. E., Hampson W. G. J., Goodship A. E., Shah J. S. Bone deformation recorded in vivo from strain gauges attached to the human tibial shaft. Acta Orthop. Scand. 46:1975;256-268.
    • (1975) Acta Orthop. Scand. , vol.46 , pp. 256-268
    • Lanyon, L.E.1    Hampson, W.G.J.2    Goodship, A.E.3    Shah, J.S.4
  • 16
    • 0019162415 scopus 로고
    • Anatomy of the microvasculature of the tinial diaphysis of the adult dog
    • Lopez-Curto J. A., Bassingthwaighte J. H., Kelly P. J. Anatomy of the microvasculature of the tinial diaphysis of the adult dog. J. Bone Joint Surg. 62A:1980;1362-1369.
    • (1980) J. Bone Joint Surg. , vol.62 , pp. 1362-1369
    • Lopez-Curto, J.A.1    Bassingthwaighte, J.H.2    Kelly, P.J.3
  • 17
    • 0002539894 scopus 로고
    • Streaming potential in home
    • V. C. Mow. Springer-Verlag
    • Mak A. F. T. Streaming potential in home. Mow V. C. Biomechanics of Diarthrodial Joints. 1990;175-194 Springer-Verlag.
    • (1990) Biomechanics of Diarthrodial Joints , pp. 175-194
    • Mak, A.F.T.1
  • 18
    • 0031060070 scopus 로고    scopus 로고
    • Deformation-induced hierarchical flows and drag forces in bone canaliculi and matrix microporosity
    • Mak A. F. T., Huang D. T., Zhang J. D., Tong P. Deformation-induced hierarchical flows and drag forces in bone canaliculi and matrix microporosity. J. Biomech. 30:1997;11-18.
    • (1997) J. Biomech. , vol.30 , pp. 11-18
    • Mak, A.F.T.1    Huang, D.T.2    Zhang, J.D.3    Tong, P.4
  • 20
    • 0023888217 scopus 로고
    • Streaming potentials in chemically modified bone
    • Otter M., Goheen S., Williams W. S. Streaming potentials in chemically modified bone. J. Ortho. Res. 6:1988;346-359.
    • (1988) J. Ortho. Res. , vol.6 , pp. 346-359
    • Otter, M.1    Goheen, S.2    Williams, W.S.3
  • 21
    • 0025190291 scopus 로고
    • Transcortical streaming potentials are generated by circulatory pressure gradients in living canine tibia
    • Otter M. W., Palmieri V. R., Cochran G. V. B. Transcortical streaming potentials are generated by circulatory pressure gradients in living canine tibia. J. Ortho. Res. 8:1990;119-126.
    • (1990) J. Ortho. Res. , vol.8 , pp. 119-126
    • Otter, M.W.1    Palmieri, V.R.2    Cochran, G.V.B.3
  • 22
    • 0024421310 scopus 로고
    • A discrete model for streaming potentials in a single osteon
    • Ptrov N., Pollack S., Blagoeva R. A discrete model for streaming potentials in a single osteon. J. Biomech. 22:1989;517-521.
    • (1989) J. Biomech. , vol.22 , pp. 517-521
    • Ptrov, N.1    Pollack, S.2    Blagoeva, R.3
  • 24
    • 0344242069 scopus 로고    scopus 로고
    • Histomorphological study on pattern of fluid movement in cortical bone in goats
    • Qin L., Mak A. F. T., Cheng C. W., Hung L. K., Chan K. M. Histomorphological study on pattern of fluid movement in cortical bone in goats. Anat. Rec. 1999.
    • (1999) Anat. Rec.
    • Qin, L.1    Mak, A.F.T.2    Cheng, C.W.3    Hung, L.K.4    Chan, K.M.5
  • 25
    • 0000463964 scopus 로고    scopus 로고
    • Changes in osteocytes, lacunal, and canaliculi with age in osteons of human compact bone
    • Qiu S., Schaffler M. B. Changes in osteocytes, lacunal, and canaliculi with age in osteons of human compact bone. Trans. Ortho. Res. Soc. Annu. Meeting. 1998;541.
    • (1998) Trans. Ortho. Res. Soc. Annu. Meeting , pp. 541
    • Qiu, S.1    Schaffler, M.B.2
  • 27
    • 0023251240 scopus 로고
    • Electromechanical potentials in cortical bone - I. A continuum approach
    • Salzstein R. A., Pollack S. R., Mak A. F. T., Petrov N. Electromechanical potentials in cortical bone - I. A continuum approach. J. Biomech. 20:1987;261-270.
    • (1987) J. Biomech. , vol.20 , pp. 261-270
    • Salzstein, R.A.1    Pollack, S.R.2    Mak, A.F.T.3    Petrov, N.4
  • 28
    • 0014739878 scopus 로고
    • Tissue fluid movement in compact bone
    • Seliger W. G. Tissue fluid movement in compact bone. Anat. Rec. 166:1970;247-256.
    • (1970) Anat. Rec. , vol.166 , pp. 247-256
    • Seliger, W.G.1
  • 29
    • 0018514836 scopus 로고
    • Microelectrode studies of stress generated potentials in four point bending of bone
    • Starkebaum W., Pollack S. R., Korostoff E. Microelectrode studies of stress generated potentials in four point bending of bone. J. Biomed. Mater. Res. 13:1979;729-751.
    • (1979) J. Biomed. Mater. Res. , vol.13 , pp. 729-751
    • Starkebaum, W.1    Pollack, S.R.2    Korostoff, E.3
  • 30
    • 0028386524 scopus 로고
    • A model for the ercitation of osteocytes by mechanical loading-induced bone fluid shear stresses
    • Weinbaum S., Cowin S. C., Zeng Y. A model for the ercitation of osteocytes by mechanical loading-induced bone fluid shear stresses. J. Biomech. 27:1994;339-360.
    • (1994) J. Biomech. , vol.27 , pp. 339-360
    • Weinbaum, S.1    Cowin, S.C.2    Zeng, Y.3
  • 31
    • 0029395299 scopus 로고
    • A case for bone canaliculi as the anatomical site of strain generated potentials
    • Cowin S. C., Weinbaum S., Zeng Y. A case for bone canaliculi as the anatomical site of strain generated potentials. J. Biomech. 28:1995;1281-1297.
    • (1995) J. Biomech. , vol.28 , pp. 1281-1297
    • Cowin, S.C.1    Weinbaum, S.2    Zeng, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.