메뉴 건너뛰기




Volumn 41, Issue 3, 2000, Pages 548-555

Angulation errors in parallel-hole and fanbeam collimators: Computer controlled quality control and acceptance testing procedure

Author keywords

Angulation; Collimator; Computer control; Quality control

Indexed keywords

ACCURACY; ARTICLE; AUTOMATION; COLLIMATOR; COMPUTER PROGRAM; COMPUTER SYSTEM; IMAGE QUALITY; PRIORITY JOURNAL; QUALITY CONTROL; SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY;

EID: 0034007042     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (17)
  • 1
    • 0023882561 scopus 로고
    • New methods of examining gamma camera collimators
    • Chang W, Li S, Williams J, et al. New methods of examining gamma camera collimators. J Nucl Med. 1988;29:676-683.
    • (1988) J Nucl Med. , vol.29 , pp. 676-683
    • Chang, W.1    Li, S.2    Williams, J.3
  • 3
    • 0021435261 scopus 로고
    • The effect of collimators on the center of rotation in SPECT
    • Farrell TJ, Cradduck TD, Chamberlain RA. The effect of collimators on the center of rotation in SPECT. J Nucl Med. 1984;25:632-633.
    • (1984) J Nucl Med. , vol.25 , pp. 632-633
    • Farrell, T.J.1    Cradduck, T.D.2    Chamberlain, R.A.3
  • 5
    • 0030253119 scopus 로고    scopus 로고
    • Instrument- and computer-related problems and artifacts in nuclear medicine
    • O'Connor MK. Instrument- and computer-related problems and artifacts in nuclear medicine. Semin Nucl Med. 1996;26:256-277.
    • (1996) Semin Nucl Med. , vol.26 , pp. 256-277
    • O'Connor, M.K.1
  • 6
    • 0029400243 scopus 로고
    • The AAPM/RSNA physics tutorial for residents: Quality control for SPECT systems
    • Graham LS. The AAPM/RSNA physics tutorial for residents: quality control for SPECT systems. RadioGraphics. 1995;15:1471-1481.
    • (1995) RadioGraphics , vol.15 , pp. 1471-1481
    • Graham, L.S.1
  • 7
    • 0023618547 scopus 로고
    • Measurement of collimator hole angulation and camera head-tilt for slant and parallel hole collimators used in SPECT
    • Busemann-Sokole E. Measurement of collimator hole angulation and camera head-tilt for slant and parallel hole collimators used in SPECT. J Nucl Med. 1987;28:1592-1598.
    • (1987) J Nucl Med. , vol.28 , pp. 1592-1598
    • Busemann-Sokole, E.1
  • 8
    • 0003635157 scopus 로고
    • Standards publication NU-1-1994. Washington, DC: National Electric Manufacturers Association
    • Performance Measurements of Scintillation Cameras. Standards publication NU-1-1994. Washington, DC: National Electric Manufacturers Association; 1994.
    • (1994) Performance Measurements of Scintillation Cameras
  • 10
    • 0030996611 scopus 로고    scopus 로고
    • Simulation study of the influence of collimator defects on the uniformity of scintigraphic images
    • Gantet P, De Lagrevol R, Danet B, De la Barre F, Guiraud R. Simulation study of the influence of collimator defects on the uniformity of scintigraphic images [in French]. Phys Med Biol. 1997;42:603-609.
    • (1997) Phys Med Biol. , vol.42 , pp. 603-609
    • Gantet, P.1    De Lagrevol, R.2    Danet, B.3    De La Barre, F.4    Guiraud, R.5
  • 11
    • 0025293882 scopus 로고
    • Collimator angulation error and its effect on SPECT
    • Malmin RE, Stanley PC, Guth WR. Collimator angulation error and its effect on SPECT. J Nucl Med. 1990;31:655-659.
    • (1990) J Nucl Med. , vol.31 , pp. 655-659
    • Malmin, R.E.1    Stanley, P.C.2    Guth, W.R.3
  • 12
    • 0342817589 scopus 로고
    • Affects of unseen collimator defects on center of rotation measurements
    • Karlovich CA, Halama JR, Henkin RE. Affects of unseen collimator defects on center of rotation measurements [abstract]. J Nucl Med Technol. 1990;18:137.
    • (1990) J Nucl Med Technol. , vol.18 , pp. 137
    • Karlovich, C.A.1    Halama, J.R.2    Henkin, R.E.3
  • 13
    • 0023713563 scopus 로고
    • The influence of collimators on SPECT center of rotation measurements: Artifact generation and acceptance testing
    • Cerqueira MD, Matsuoka D, Ritchie JL, Harp GD. The influence of collimators on SPECT center of rotation measurements: artifact generation and acceptance testing. J Nucl Med. 1988;29:1393-1397.
    • (1988) J Nucl Med. , vol.29 , pp. 1393-1397
    • Cerqueira, M.D.1    Matsuoka, D.2    Ritchie, J.L.3    Harp, G.D.4
  • 14
    • 0024996666 scopus 로고
    • Defective parallel-hole collimator encountered in SPECT: A suggested approach to avoid potential problems
    • Yoshizumi TT, Suneja SK, Teal JS, Sutton AM, Collyer D. Defective parallel-hole collimator encountered in SPECT: a suggested approach to avoid potential problems. J Nucl Med. 1990;31:1892-1893.
    • (1990) J Nucl Med. , vol.31 , pp. 1892-1893
    • Yoshizumi, T.T.1    Suneja, S.K.2    Teal, J.S.3    Sutton, A.M.4    Collyer, D.5
  • 15
    • 0024616044 scopus 로고
    • Influence of collimators on SPECT center of rotation measurements
    • O'Connor MK, Oswald WM. Influence of collimators on SPECT center of rotation measurements. J Nucl Med. 1989;30:265-266.
    • (1989) J Nucl Med. , vol.30 , pp. 265-266
    • O'Connor, M.K.1    Oswald, W.M.2
  • 16
    • 0020995107 scopus 로고
    • Polarity in a hexagonal collimator
    • Yeh E. Polarity in a hexagonal collimator. J Nucl Med. 1983;24:1203-1204.
    • (1983) J Nucl Med. , vol.24 , pp. 1203-1204
    • Yeh, E.1
  • 17
    • 0023820205 scopus 로고
    • Nonisotropic point spread function as a result of collimator design and manufacturing defects
    • Gillen GJ. Nonisotropic point spread function as a result of collimator design and manufacturing defects. J Nucl Med. 1988;29:1096-1100.
    • (1988) J Nucl Med. , vol.29 , pp. 1096-1100
    • Gillen, G.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.