1
-
-
84907109127
-
Non-uniformity induced artifacts in single-photon emission computed tomography
-
Fasc 3
-
Axelsson B, Israelsson A and Larsson S 1983 Non-uniformity induced artifacts in single-photon emission computed tomography Acta Radiologica Oncology 22 Fasc 3
-
(1983)
Acta Radiologica Oncology
, vol.22
-
-
Axelsson, B.1
Israelsson, A.2
Larsson, S.3
-
2
-
-
0023618547
-
Measurement of collimator hole angulation and camera head tilt for slant and parallel hole collimators used in SPECT
-
Busemann-Sokole E 1987 Measurement of collimator hole angulation and camera head tilt for slant and parallel hole collimators used in SPECT J. Nucl. Med. 28 1592-8
-
(1987)
J. Nucl. Med.
, vol.28
, pp. 1592-1598
-
-
Busemann-Sokole, E.1
-
3
-
-
0023713563
-
The influence of collimators on SPECT center of rotation measurements: Artifacts generation and acceptance testing
-
Cerqueira M D, Matsuoka D, Ritchie J L and Harp G D 1988 The influence of collimators on SPECT center of rotation measurements: artifacts generation and acceptance testing J. Nucl. Med. 29 1393-7
-
(1988)
J. Nucl. Med.
, vol.29
, pp. 1393-1397
-
-
Cerqueira, M.D.1
Matsuoka, D.2
Ritchie, J.L.3
Harp, G.D.4
-
4
-
-
0023882561
-
New methods of examining gamma camera collimators
-
Chang W, Li S, Williams J J, Bruch P M, Wesolowski C A, Ehrhardt J C and Kirchner P T 1988 New methods of examining gamma camera collimators J. Nucl. Med. 29 676-83
-
(1988)
J. Nucl. Med.
, vol.29
, pp. 676-683
-
-
Chang, W.1
Li, S.2
Williams, J.J.3
Bruch, P.M.4
Wesolowski, C.A.5
Ehrhardt, J.C.6
Kirchner, P.T.7
-
5
-
-
1842293523
-
Etude en simulation de l'amplification des défauts d'uniformité en SPECT
-
de Lagrevol R, Gantet P, Danet B, de la Barrre F and Guiraud R 1995 Etude en simulation de l'amplification des défauts d'uniformité en SPECT Innov. Tech. Biol. Med. 16 602-8
-
(1995)
Innov. Tech. Biol. Med.
, vol.16
, pp. 602-608
-
-
De Lagrevol, R.1
Gantet, P.2
Danet, B.3
De la Barrre, F.4
Guiraud, R.5
-
6
-
-
0025426691
-
Une méthode d'étude par simulation des collimateurs des caméras à scintillation
-
Gantet P, Esquerré J P, Danet B and Guiraud R 1990 Une méthode d'étude par simulation des collimateurs des caméras à scintillation. A simulation method for studying scintillation camera collimators Phys. Med. Biol. 35 659-69
-
(1990)
Phys. Med. Biol.
, vol.35
, pp. 659-669
-
-
Gantet, P.1
Esquerré, J.P.2
Danet, B.3
Guiraud, R.4
-
7
-
-
0023820205
-
Nonistropic point spread function as a result of collimator design and manufacturing defects
-
Gillen G J, Hilditch T E and Elliott A T 1988 Nonistropic point spread function as a result of collimator design and manufacturing defects J. Nucl. Med. 29 1096-100
-
(1988)
J. Nucl. Med.
, vol.29
, pp. 1096-1100
-
-
Gillen, G.J.1
Hilditch, T.E.2
Elliott, A.T.3
-
8
-
-
0023108978
-
An analytical approach to quantify uniformity artifacts for circular and noncircular detector motion in SPECT imaging
-
Gullberg G T 1987 An analytical approach to quantify uniformity artifacts for circular and noncircular detector motion in SPECT imaging Med. Phys. 14 105-14
-
(1987)
Med. Phys.
, vol.14
, pp. 105-114
-
-
Gullberg, G.T.1
-
9
-
-
0017543010
-
The influence of fixed errors of a detector array on the reconstruction of objects from their projections
-
Kowalski G 1977 The influence of fixed errors of a detector array on the reconstruction of objects from their projections IEEE Trans. Nucl. Sci. 24 2006-16
-
(1977)
IEEE Trans. Nucl. Sci.
, vol.24
, pp. 2006-2016
-
-
Kowalski, G.1
-
10
-
-
0025293882
-
Collimator angulation error and its effect on SPECT
-
Malmin R E, Stanley P C and Guth W R 1990 Collimator angulation error and its effect on SPECT J. Nucl. Med. 31 655-9
-
(1990)
J. Nucl. Med.
, vol.31
, pp. 655-659
-
-
Malmin, R.E.1
Stanley, P.C.2
Guth, W.R.3
-
11
-
-
0022404853
-
Uniformity correction for SPECT using a mapped cobalt-57 sheet source
-
Oppenheim B E and Appledorn C R 1985 Uniformity correction for SPECT using a mapped cobalt-57 sheet source J. Nucl. Med. 26 409-15
-
(1985)
J. Nucl. Med.
, vol.26
, pp. 409-415
-
-
Oppenheim, B.E.1
Appledorn, C.R.2
-
12
-
-
0020059504
-
Field-flood requirements for emission computed tomography with an Anger camera
-
Rogers W L, Clinthorne N H, Harkness B A, Koral K F and Keyes J W 1982 Field-flood requirements for emission computed tomography with an Anger camera J. Nucl. Med. 23 162-8
-
(1982)
J. Nucl. Med.
, vol.23
, pp. 162-168
-
-
Rogers, W.L.1
Clinthorne, N.H.2
Harkness, B.A.3
Koral, K.F.4
Keyes, J.W.5
-
13
-
-
25544453083
-
Verifying hole angulation of collimators for SPECT imaging
-
Sloboda R S, Hooper H R and Logus J W 1990 Verifying hole angulation of collimators for SPECT imaging J. Nucl. Med. 26 S81
-
(1990)
J. Nucl. Med.
, vol.26
-
-
Sloboda, R.S.1
Hooper, H.R.2
Logus, J.W.3
-
15
-
-
0024996666
-
Defective parallel-hole collimator encountered in SPECT: A suggested approach to avoid potential problems
-
Yoshizumi T T, Suneja S K and Teal J S 1990 Defective parallel-hole collimator encountered in SPECT: a suggested approach to avoid potential problems J. Nucl. Med. 31 1892-3
-
(1990)
J. Nucl. Med.
, vol.31
, pp. 1892-1893
-
-
Yoshizumi, T.T.1
Suneja, S.K.2
Teal, J.S.3
|