메뉴 건너뛰기




Volumn 37, Issue 2, 1997, Pages 483-487

Validity of the interval method for the determination of the anisotropy factor of high dose rate 192IR sources

Author keywords

Anisotropy factor; High dose rate 192Ir source; Interval method; Sievert integral

Indexed keywords

IRIDIUM 192;

EID: 0030887668     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(96)00509-3     Document Type: Article
Times cited : (4)

References (14)
  • 3
    • 0343435276 scopus 로고
    • A comparison of different planning algorithms used in interstitial radiotherapy with Iridium-192 wires
    • Mould, R. F., ed. Columbia, MD: Nucletron
    • Kilian, H.; Baier, K.; Loffler, E.; Sussenbach, K.; Dorner, K. A. A comparison of different planning algorithms used in interstitial radiotherapy with Iridium-192 wires. In: Mould, R. F., ed. Brachytherapy 2. Columbia, MD: Nucletron; 1989:92-100.
    • (1989) Brachytherapy , vol.2 , pp. 92-100
    • Kilian, H.1    Baier, K.2    Loffler, E.3    Sussenbach, K.4    Dorner, K.A.5
  • 5
    • 0014286055 scopus 로고
    • The effective attenuation in water of the gamma rays of gold 198, Iridium 192, Cesium 137, Radium 226 and Cobalt 60
    • Meisberger, L.; Keller, R.; Shalek, R. The effective attenuation in water of the gamma rays of Gold 198, Iridium 192, Cesium 137, Radium 226 and Cobalt 60. Radiology 90:953-957; 1968.
    • (1968) Radiology , vol.90 , pp. 953-957
    • Meisberger, L.1    Keller, R.2    Shalek, R.3
  • 6
    • 0028016360 scopus 로고
    • Anisotropy measurements of a high dose rate Ir-192 source in air and in polystyrene
    • Muller-Runkel, R.; Cho, S. H. Anisotropy measurements of a high dose rate Ir-192 source in air and in polystyrene. Med. Phys. 21(7):1131-1134; 1994.
    • (1994) Med. Phys. , vol.21 , Issue.7 , pp. 1131-1134
    • Muller-Runkel, R.1    Cho, S.H.2
  • 8
    • 64049100644 scopus 로고
    • Intensitatsverteilung der primaren gammastrahlung in der nahe medizinischer radiumpraparate
    • Sievert, R. M. Intensitatsverteilung der primaren Gammastrahlung in der Nahe medizinischer Radiumpraparate. Acta Radiol. 1:89-98; 1921.
    • (1921) Acta Radiol. , vol.1 , pp. 89-98
    • Sievert, R.M.1
  • 11
    • 0020592244 scopus 로고
    • Monte Carlo evaluation of the Sievert integral for brachytherapy dosimetry
    • Williamson, J. F.; Morin, R. L.; Khan, F. M. Monte Carlo evaluation of the Sievert integral for brachytherapy dosimetry. Phys. Med. Biol. 28:1021-1032; 1983.
    • (1983) Phys. Med. Biol. , vol.28 , pp. 1021-1032
    • Williamson, J.F.1    Morin, R.L.2    Khan, F.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.