메뉴 건너뛰기




Volumn 27, Issue 1, 2000, Pages 231-238

Estimation of the dose at the maze entrance for x-rays from radiotherapy linear accelerators

Author keywords

Dose; NCRP formula; Radiotherapy room maze entrance

Indexed keywords

LIGHT SCATTERING; PHOTONS; RADIOTHERAPY;

EID: 0033971653     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598887     Document Type: Article
Times cited : (16)

References (23)
  • 1
    • 0003696440 scopus 로고
    • Radiation protection design guidelines for 0.1-100 MeV particle accelerator facilities
    • NCRP, Bethesda, MD
    • National Council on Radiation Protection and Measurements, NCRP Report No. 51, "Radiation Protection Design Guidelines for 0.1-100 MeV Particle Accelerator Facilities" (NCRP, Bethesda, MD, 1977).
    • (1977) NCRP Report No. 51
  • 2
    • 0028783453 scopus 로고
    • Dose rates and energy spectra in the maze of a linear accelerator treatment room
    • S. Morgan, H. M. Morgan, and S. C. Lillicrap, "Dose rates and energy spectra in the maze of a linear accelerator treatment room," Br. J. Radiol. 68, 1237-1241 (1995).
    • (1995) Br. J. Radiol. , vol.68 , pp. 1237-1241
    • Morgan, S.1    Morgan, H.M.2    Lillicrap, S.C.3
  • 3
    • 0021907052 scopus 로고
    • Radiation transmission and scattering for medical linacs producing x-rays of 6 and 15 MV: Comparison of calculations with measurements
    • N. J. Numark and K. R. Kase, "Radiation transmission and scattering for medical linacs producing x-rays of 6 and 15 MV: Comparison of calculations with measurements," Health Phys. 48, 289-295 (1985).
    • (1985) Health Phys. , vol.48 , pp. 289-295
    • Numark, N.J.1    Kase, K.R.2
  • 5
    • 0030253442 scopus 로고    scopus 로고
    • Dose rates and energy spectra in the maze of a linear accelerator treatment room
    • S. Morgan, H. M. Morgan, and S. C. Lillicrap, "Dose rates and energy spectra in the maze of a linear accelerator treatment room," Br. J. Radiol. 69, 977 (1996).
    • (1996) Br. J. Radiol. , vol.69 , pp. 977
    • Morgan, S.1    Morgan, H.M.2    Lillicrap, S.C.3
  • 6
    • 0026049708 scopus 로고
    • Calculation of shielding door thicknesses for radiation therapy facilities using the ITS Monte Carlo program
    • P. J. Biggs, "Calculation of shielding door thicknesses for radiation therapy facilities using the ITS Monte Carlo program," Health Phys. 61, 465-472 (1991).
    • (1991) Health Phys. , vol.61 , pp. 465-472
    • Biggs, P.J.1
  • 7
    • 0029824178 scopus 로고    scopus 로고
    • Radiation quality of scattered photons at the maze entrance of radiotherapy rooms for photon beams of energy 0.5-30 MeV
    • I. A. M. Al-Affan and C. W. Smith, "Radiation quality of scattered photons at the maze entrance of radiotherapy rooms for photon beams of energy 0.5-30 MeV," Radiat. Prot. Dosim. 67, 299-302 (1996).
    • (1996) Radiat. Prot. Dosim. , vol.67 , pp. 299-302
    • Al-Affan, I.A.M.1    Smith, C.W.2
  • 8
    • 85027222788 scopus 로고    scopus 로고
    • The use of computer programs in treatment room design
    • edited by B. Stedeford, H. M. Morgan, and W. P. M. Mayles IPEM Report No. 75, IPEM, U.K.
    • C. W. Smith, I. A. M. A-Affan, and S. Green, "The use of computer programs in treatment room design," in The Design of Radiotherapy Treatment Room Facilities, edited by B. Stedeford, H. M. Morgan, and W. P. M. Mayles (IPEM Report No. 75, IPEM, U.K., 1997), p. 72.
    • (1997) The Design of Radiotherapy Treatment Room Facilities , pp. 72
    • Smith, C.W.1    A-Affan, I.A.M.2    Green, S.3
  • 9
    • 85040280885 scopus 로고
    • Protection against ionising radiation from external sources used in medicine
    • Pergamon Press, Oxford
    • International Commission on Radiological Protection, "Protection against ionising radiation from external sources used in medicine," ICRP Publication 33 (Pergamon Press, Oxford, 1982).
    • (1982) ICRP Publication 33
  • 12
    • 0040532751 scopus 로고
    • Backscattering of gamma rays from point source by an infinite-plane concrete surface
    • A. B. Chilton, "Backscattering of gamma rays from point source by an infinite-plane concrete surface," Nucl. Sci. Eng. 21, 194-200 (1965).
    • (1965) Nucl. Sci. Eng. , vol.21 , pp. 194-200
    • Chilton, A.B.1
  • 14
    • 0028575651 scopus 로고
    • An analytic calculation of the energy fluence spectrum of a linear accelerator
    • G. E. Desobry and A. L. Boyer, "An analytic calculation of the energy fluence spectrum of a linear accelerator," Med. Phys. 21, 1943-1952 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1943-1952
    • Desobry, G.E.1    Boyer, A.L.2
  • 15
    • 0027997782 scopus 로고
    • Calculation and measurement of the dose at points outside the primary beam for photon energies of 6, 10 and 23 MV
    • P. Van der Giessen, "Calculation and measurement of the dose at points outside the primary beam for photon energies of 6, 10 and 23 MV," Int. J. Radiat. Oncol., Biol., Phys. 30, 1239-1246 (1994).
    • (1994) Int. J. Radiat. Oncol., Biol., Phys. , vol.30 , pp. 1239-1246
    • Van Der Giessen, P.1
  • 16
    • 0031782974 scopus 로고    scopus 로고
    • Dose rate and energy distributions of x-rays from a linear accelerator at the maze entrance of a radiotherapy room by measurement and Monte Carlo Simulation
    • I. A. M. Al-Affan, C. W. Smith, H. M. Morgan, and S. C. Lillicrap, "Dose rate and energy distributions of x-rays from a linear accelerator at the maze entrance of a radiotherapy room by measurement and Monte Carlo Simulation," Radiat. Prot. Dosim. 78, 273-277 (1998).
    • (1998) Radiat. Prot. Dosim. , vol.78 , pp. 273-277
    • Al-Affan, I.A.M.1    Smith, C.W.2    Morgan, H.M.3    Lillicrap, S.C.4
  • 17
    • 0014265919 scopus 로고
    • Measurement of 6 MV X rays II. Characteristics of secondary radiation
    • C. J. Karzmark and T. Capone, "Measurement of 6 MV X rays II. Characteristics of secondary radiation," Br. J. Radiol. 41, 222-226 (1968).
    • (1968) Br. J. Radiol. , vol.41 , pp. 222-226
    • Karzmark, C.J.1    Capone, T.2
  • 18
    • 0014266884 scopus 로고
    • Measurement of 6 MV X rays III. Characteristics of leakage radiation
    • T. Capone and C. J. Karzmark, "Measurement of 6 MV X rays III. Characteristics of leakage radiation," Br. J. Radiol. 41, 227-230 (1968).
    • (1968) Br. J. Radiol. , vol.41 , pp. 227-230
    • Capone, T.1    Karzmark, C.J.2
  • 19
    • 0014594640 scopus 로고
    • The relative importance of leakage and scatter in megavoltage installation design
    • A. C. McEwan, "The relative importance of leakage and scatter in megavoltage installation design," Phys. Med. Biol. 14, 659-660 (1969).
    • (1969) Phys. Med. Biol. , vol.14 , pp. 659-660
    • McEwan, A.C.1
  • 20
    • 0021712765 scopus 로고
    • Primary and leakage radiation calculations at 6, 10 and 25 MeV
    • W. R. Nelson and P. D. LaRiviere, "Primary and leakage radiation calculations at 6, 10 and 25 MeV," Health Phys. 47, 811-818 (1984).
    • (1984) Health Phys. , vol.47 , pp. 811-818
    • Nelson, W.R.1    LaRiviere, P.D.2
  • 21
    • 0028129772 scopus 로고
    • A Monte Carlo study of accelerator head scatter
    • E. L. Chaney, T. J. Cullip, and T. A. Gabriel, "A Monte Carlo study of accelerator head scatter," Med. Phys. 21, 1383-1390 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1383-1390
    • Chaney, E.L.1    Cullip, T.J.2    Gabriel, T.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.