메뉴 건너뛰기




Volumn 78, Issue 4, 1998, Pages 273-277

Dose rate and energy distributions of X rays from a linear accelerator at the maze entrance of a radiotherapy room by measurement and Monte Carlo simulation

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; DOSIMETRY; LINEAR ACCELERATOR; NEUTRON RADIATION; PHANTOM; RADIATION DOSE; RADIATION EXPOSURE; RADIATION PROTECTION; RADIOTHERAPY; SYSTEM ANALYSIS; X RAY;

EID: 0031782974     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a032360     Document Type: Article
Times cited : (8)

References (10)
  • 1
    • 0026049708 scopus 로고
    • Calculation of Shielding Door Thicknesses for Radiation Therapy Facilities using the ITS Monte Carlo Program
    • Biggs, P. J. Calculation of Shielding Door Thicknesses for Radiation Therapy Facilities using the ITS Monte Carlo Program. Health Phys. 61, 465-472 (1991).
    • (1991) Health Phys. , vol.61 , pp. 465-472
    • Biggs, P.J.1
  • 2
    • 0028783453 scopus 로고
    • Dose Rates and Energy Spectra in the Maze of a Linear Accelerator Treatment Room
    • Morgan, S., Morgan, H. M. and Lillicrap, S. C. Dose Rates and Energy Spectra in the Maze of a Linear Accelerator Treatment Room. Br. J. Radiol. 68, 1237-1241 (1995).
    • (1995) Br. J. Radiol. , vol.68 , pp. 1237-1241
    • Morgan, S.1    Morgan, H.M.2    Lillicrap, S.C.3
  • 3
    • 0029824178 scopus 로고    scopus 로고
    • Radiation Quality of Scattered Photons at the Maze Entrance of Radiotherapy Rooms for Photon Beams of Energy 0.5-30 MeV
    • Al-Affan, I. A. and Smith, C. W. Radiation Quality of Scattered Photons at the Maze Entrance of Radiotherapy Rooms for Photon Beams of Energy 0.5-30 MeV. Radiat. Prot. Dosim. 67, 299-302 (1996).
    • (1996) Radiat. Prot. Dosim. , vol.67 , pp. 299-302
    • Al-Affan, I.A.1    Smith, C.W.2
  • 4
    • 0003696440 scopus 로고
    • Radiation Protection Design Guidelines for 0.1-100 MeV Particle Accelerator Facilities
    • Bethesda, MD, USA: NCRP
    • National Council on Radiation Protection and Measurements. Radiation Protection Design Guidelines for 0.1-100 MeV Particle Accelerator Facilities. NCRP Report No 51 (Bethesda, MD, USA: NCRP) (1977).
    • (1977) NCRP Report No 51
  • 5
    • 0342438205 scopus 로고    scopus 로고
    • Maze Design Methods for 6 and 1O MeV Accelerators
    • McGinley, P. H. and James, J. L. Maze Design Methods for 6 and 1O MeV Accelerators. Radiat Prot Manag. 14, 59-64 (1997).
    • (1997) Radiat Prot Manag. , vol.14 , pp. 59-64
    • McGinley, P.H.1    James, J.L.2
  • 7
    • 0021712765 scopus 로고
    • Primary and Leakage Radiation Calculations at 6, 1O and 25 MeV
    • Nelson, W. R. and LaRiviere, P. D. Primary and Leakage Radiation Calculations at 6, 1O and 25 MeV. Health Phys 47, 811-818(1984).
    • (1984) Health Phys , vol.47 , pp. 811-818
    • Nelson, W.R.1    LaRiviere, P.D.2
  • 8
    • 0021849353 scopus 로고
    • Energy and Angular Distributions of Photons from Medical Linear Accelerators
    • Mohan, R. and Chen, C. Energy and Angular Distributions of Photons from Medical Linear Accelerators. Med. Phys. 12, 592-597 (1985).
    • (1985) Med. Phys. , vol.12 , pp. 592-597
    • Mohan, R.1    Chen, C.2
  • 10
    • 0030253442 scopus 로고    scopus 로고
    • Dose Rates and Energ Spectra in the Maze of a Linear Accelerator Treatment Room
    • Morgan, S., Morgan, H. M. and Lillicrap, S. C. Dose Rates and Energ Spectra in the Maze of a Linear Accelerator Treatment Room. Br. J. Radiol. 69, 977 (1996).
    • (1996) Br. J. Radiol. , vol.69 , pp. 977
    • Morgan, S.1    Morgan, H.M.2    Lillicrap, S.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.