메뉴 건너뛰기




Volumn 15, Issue 1, 2000, Pages 68-71

The international conventions for health-related sampling of aerosols—a review of current status and future evolution

Author keywords

Inhalable Dust; Particle Size Selective Sampling; Respirable Dust; Thoracic Dust

Indexed keywords

AEROSOL; AIR QUALITY; AIR SAMPLING; CONFERENCE PAPER; DUST; HUMAN; INDUSTRIAL HYGIENE; INTERNATIONAL COOPERATION; PRIORITY JOURNAL; QUALITY CONTROL; THORAX; WORKPLACE;

EID: 0033955541     PISSN: 1047322X     EISSN: None     Source Type: Journal    
DOI: 10.1080/104732200301863     Document Type: Article
Times cited : (3)

References (35)
  • 1
    • 85012520305 scopus 로고
    • Workplace Atmospheres: Size Fraction Definitions for Measurement of Airborne Particles in theWorkplace. CEN Standard EN 481. CEN, Brussels
    • Comité Européen de Normalisation (CEN): Workplace Atmospheres: Size Fraction Definitions for Measurement of Airborne Particles in theWorkplace. CEN Standard EN 481. CEN, Brussels (1993).
    • (1993)
  • 2
    • 85012439614 scopus 로고
    • Particle Size-Selective Sampling in the Workplace. Cincinnati, OH
    • ACGIH, American Conference of Governmental Industrial Hygienists: Particle Size-Selective Sampling in the Workplace. Cincinnati, OH (1985).
    • (1985)
  • 3
    • 85012510320 scopus 로고
    • Air Quality—Particle Size Fraction Definitions for Health-Related Sampling. ISO Standard 7708. ISO, Geneva
    • International Standards Organisation (ISO): Air Quality—Particle Size Fraction Definitions for Health-Related Sampling. ISO Standard 7708. ISO, Geneva (1995).
    • (1995)
  • 4
    • 85012485957 scopus 로고
    • Ambient Air Monitoring Reference and Equivalent Methods. United States, Federal Register 40 CFR Part 53, 1
    • Environmental Protection Agency (EPA): Ambient Air Monitoring Reference and Equivalent Methods. United States, Federal Register 40 CFR Part 53 (July 1, 1987).
    • (1987) , Issue.July
  • 5
    • 85012559403 scopus 로고    scopus 로고
    • Ambient Air Monitoring Reference and Equivalent Methods. EPA, Federal Register 40 CFR Parts 50, 53 and 58 (July 18
    • EPA: Ambient Air Monitoring Reference and Equivalent Methods. EPA, Federal Register 40 CFR Parts 50, 53 and 58 (July 18, 1997).
    • (1997)
  • 6
    • 85012463445 scopus 로고    scopus 로고
    • MDHS 14/2: General Methods for the Sampling and Gravimetric Analysis of Respirable and Total Inhalable Dust. Methods for the Determination of Hazardous Substances, Number 14/2. HSE Books, United Kingdom
    • Health and Safety Executive: MDHS 14/2: General Methods for the Sampling and Gravimetric Analysis of Respirable and Total Inhalable Dust. Methods for the Determination of Hazardous Substances, Number 14/2. HSE Books, United Kingdom (1997).
    • (1997)
  • 7
    • 85012443025 scopus 로고    scopus 로고
    • BIA Arbeitsmappe—Expositionsermittlung bei Chemishen and Biologischen Einwirkungen. Erich Schmidt Verlag
    • BIA: BIA Arbeitsmappe—Expositionsermittlung bei Chemishen and Biologischen Einwirkungen. Erich Schmidt Verlag (1997).
    • (1997)
  • 8
    • 0028052144 scopus 로고
    • Respirable Aerosol Sampler Performance Testing
    • Bartley, D.L; Chen, C-C; Song, R. et al.: Respirable Aerosol Sampler Performance Testing. AIHA J 55(11):1036 (1994).
    • (1994) AIHA J , vol.55 , Issue.11 , pp. 1036
    • Bartley, D.L.1    Chen, C.-C.2    Song, R.3
  • 9
    • 0029858757 scopus 로고    scopus 로고
    • Optimisation of a Cyclone to the 1993 International Sampling Convention for Respirable Dust
    • Lidén, G.; Gudmundsson, A.: Optimisation of a Cyclone to the 1993 International Sampling Convention for Respirable Dust. Appl Occ Env Hyg 11(12):1398–1408 (1996).
    • (1996) Appl Occ Env Hyg , vol.11 , Issue.12 , pp. 1398-1408
    • Lidén, G.1    Gudmundsson, A.2
  • 10
    • 0000922001 scopus 로고
    • Sampling Efficiency Determination for Three Models of Personal Cyclone, Using an Aerodynamic Particle Sizer
    • Maynard, A.D.; Kenny, L.C.: Sampling Efficiency Determination for Three Models of Personal Cyclone, Using an Aerodynamic Particle Sizer. J Aerosol Sci 26(4):671–684 (1995).
    • (1995) J Aerosol Sci , vol.26 , Issue.4 , pp. 671-684
    • Maynard, A.D.1    Kenny, L.C.2
  • 11
    • 0031259162 scopus 로고    scopus 로고
    • Performance of a Multi-Inlet Cyclone Sampler
    • Gautam, M.; Sreenath, A.: Performance of a Multi-Inlet Cyclone Sampler. J Aerosol Sci 28(7):1265–1282 (1997).
    • (1997) J Aerosol Sci , vol.28 , Issue.7 , pp. 1265-1282
    • Gautam, M.1    Sreenath, A.2
  • 12
    • 0027420147 scopus 로고
    • Evaluation of the SKC Personal Respirable Dust Sampling Cyclone
    • Lidén, G.: Evaluation of the SKC Personal Respirable Dust Sampling Cyclone. Appl Occ Env Hyg 8(3):178–190 (1993).
    • (1993) Appl Occ Env Hyg , vol.8 , Issue.3 , pp. 178-190
    • Lidén, G.1
  • 13
    • 0032031421 scopus 로고    scopus 로고
    • Determination of Cyclone Model Variability Using a Time-of-Flight Instrument
    • Gudmundsson, A.; Lidén, G.: Determination of Cyclone Model Variability Using a Time-of-Flight Instrument. Aerosol Sci Tech 28(3):197–214 (1998).
    • (1998) Aerosol Sci Tech , vol.28 , Issue.3 , pp. 197-214
    • Gudmundsson, A.1    Lidén, G.2
  • 15
    • 0027683658 scopus 로고
    • Porous Plastic Foam Filtration Media: Penetration Characteristics and Applications in Particle Size-Selective Sampling
    • Vincent, J.H.; Aitken, R.J.; Mark, D.: Porous Plastic Foam Filtration Media: Penetration Characteristics and Applications in Particle Size-Selective Sampling. J Aerosol Sci 24(7):929 (1993).
    • (1993) J Aerosol Sci , vol.24 , Issue.7 , pp. 929
    • Vincent, J.H.1    Aitken, R.J.2    Mark, D.3
  • 16
    • 85012563675 scopus 로고    scopus 로고
    • Air Quality—Field Test Procedure to Demonstrate the Equivalence of Sampling Methods for the Thoracic Fraction of Suspended Particulate Matter (SPM) with a Reference Method for the Thoracic Fraction of SPM. CEN Draft Standard prEN123411. CEN, Brussels
    • Comité Européen de Normalisation (CEN): Air Quality—Field Test Procedure to Demonstrate the Equivalence of Sampling Methods for the Thoracic Fraction of Suspended Particulate Matter (SPM) with a Reference Method for the Thoracic Fraction of SPM. CEN Draft Standard prEN123411. CEN, Brussels (1998).
    • (1998)
  • 17
    • 85012439194 scopus 로고    scopus 로고
    • Proposal for a Council Directive Relating to Limit Values for Sulphur Dioxide, Oxides of Nitrogen, Particulate Matter and Lead in Ambient Air. Official Journal of the European Communities 98/C9/05
    • European Union (EU): Proposal for a Council Directive Relating to Limit Values for Sulphur Dioxide, Oxides of Nitrogen, Particulate Matter and Lead in Ambient Air. Official Journal of the European Communities 98/C9/05 (1998).
    • (1998)
  • 18
    • 8244264676 scopus 로고    scopus 로고
    • Outcome of a Collaborative European Study of Personal Inhalable Sampler Performance
    • Kenny, L.C.; Aitken, R.; Chalmers, C. et al. Outcome of a Collaborative European Study of Personal Inhalable Sampler Performance. Ann Occup Hyg 41(2):135–153 (1996).
    • (1996) Ann Occup Hyg , vol.41 , Issue.2 , pp. 135-153
    • Kenny, L.C.1    Aitken, R.2    Chalmers, C.3
  • 19
    • 85012515240 scopus 로고    scopus 로고
    • Assessment of Performance of Instruments for Measurement of Airborne Particles.CEN Draft Standard prEN132051, CEN, Brussels
    • CEN: Workplace Atmospheres: Assessment of Performance of Instruments for Measurement of Airborne Particles.CEN Draft Standard prEN132051, CEN, Brussels (1997).
    • (1997)
  • 20
    • 85012549987 scopus 로고    scopus 로고
    • Instrument Performance Criteria: Inhalable Aerosol Samplers, M.L. Woebkenberg, Ed
    • Bartley, D.L.: Instrument Performance Criteria: Inhalable Aerosol Samplers, M.L. Woebkenberg, Ed. Appl Occup Environ Hyg 13(5) (1998).
    • (1998) Appl Occup Environ Hyg , vol.13 , Issue.5
    • Bartley, D.L.1
  • 21
    • 0026931249 scopus 로고
    • Initial experience with the Workplace Analysis Scheme for Pro. Ciency (WASP)
    • Jackson, H.M.; West, N.G.: Initial experience with the Workplace Analysis Scheme for Pro. ciency (WASP). Ann Occup Hyg 36(5):545–561 (1992).
    • (1992) Ann Occup Hyg , vol.36 , Issue.5 , pp. 545-561
    • Jackson, H.M.1    West, N.G.2
  • 22
    • 0022638331 scopus 로고
    • Performance of Asbestos Counting Laboratories in the NIOSH Proficiency Analytical Testing (PAT) Program
    • Schlecht, P.C.; Shulman, S.A.: Performance of Asbestos Counting Laboratories in the NIOSH Proficiency Analytical Testing (PAT) Program. Am Ind Hyg Assoc J 47:259–269 (1986).
    • (1986) Am Ind Hyg Assoc J , vol.47 , pp. 259-269
    • Schlecht, P.C.1    Shulman, S.A.2
  • 23
    • 0025408937 scopus 로고
    • Simulation of Particle Size Selective Samplers Placed in a Polydisperse Aerosol
    • Fabriés, J-F.: Simulation of Particle Size Selective Samplers Placed in a Polydisperse Aerosol. Aerosol Sci Tech 12:673–685 (1990).
    • (1990) Aerosol Sci Tech , vol.12 , pp. 673-685
    • Fabriés, J.-F.1
  • 24
    • 0019827818 scopus 로고
    • On the Quantitative Definition of the Inhalability of Airborne Dust
    • Vincent J.H.; Armbruster, L.: On the Quantitative Definition of the Inhalability of Airborne Dust. Ann Occup Hyg 24(2):245–248 (1981).
    • (1981) Ann Occup Hyg , vol.24 , Issue.2 , pp. 245-248
    • Vincent, J.H.1    Armbruster, L.2
  • 29
    • 85012462520 scopus 로고    scopus 로고
    • Personal communication. EU(DGXII) Proposal SMT4- Pl97-3522, information available from author
    • Mark, D.: Personal communication. EU(DGXII) Proposal SMT4- Pl97-3522, information available from author (1997).
    • (1997)
    • Mark, D.1
  • 30
    • 85012564945 scopus 로고    scopus 로고
    • Towards a New Method for Experimental Determination of Aerosol Sampler Aspiration Efficiency in Small Wind Tunnels
    • press
    • Ramachandran, G.; Sreenath, A.; Vincent, J.H.: Towards a New Method for Experimental Determination of Aerosol Sampler Aspiration Efficiency in Small Wind Tunnels. J Aerosol Sci (in press) (1997).
    • (1997) J Aerosol Sci
    • Ramachandran, G.1    Sreenath, A.2    Vincent, J.H.3
  • 32
    • 85012440374 scopus 로고    scopus 로고
    • Personal communication
    • Vincent, J.H.: Personal communication (1997).
    • (1997)
    • Vincent, J.H.1
  • 33
    • 0029849554 scopus 로고    scopus 로고
    • Free Radical and Pro-Inflammatory Activity of Particulate Air Pollution (PM10) in Vitro and in Vivo
    • Li, X.Y.; Gilmour, P.S.; Donaldson, K. et al.: Free Radical and Pro-Inflammatory Activity of Particulate Air Pollution (PM10) in Vitro and in Vivo. Thorax 51:1216–1222 (1996).
    • (1996) Thorax , vol.51 , pp. 1216-1222
    • Li, X.Y.1    Gilmour, P.S.2    Donaldson, K.3
  • 34
    • 0001386952 scopus 로고
    • Regional Deposition of Particles in theHuman Respiratory Tract
    • Williams & Wilkins, Baltimore, MD
    • Lippmann, M.: Regional Deposition of Particles in theHuman Respiratory Tract. In: Handbook of Physiology, Section IV, Environmental Physiology, pp. 213–232. Williams & Wilkins, Baltimore, MD (1977).
    • (1977) Handbook of Physiology, Section IV, Environmental Physiology , pp. 213-232
    • Lippmann, M.1
  • 35
    • 0019267685 scopus 로고
    • Physical Factors Determining Particle Deposition in the Human Respiratory Tract
    • Heyder, J.; Gebhardt, J.; Rudolf, G.; Stahlhofen, W.: Physical Factors Determining Particle Deposition in the Human Respiratory Tract. J Aerosol Sci 11:505–515 (1980).
    • (1980) J Aerosol Sci , vol.11 , pp. 505-515
    • Heyder, J.1    Gebhardt, J.2    Rudolf, G.3    Stahlhofen, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.