Volumn 24, Issue 3, 2000, Pages 198-201

Ultrasonic pulsed doppler blood flowmeter for use in extracorporeal circulation

Author keywords

Blood flowmeter; Doppler; Extracorporeal circulation; Heart lung bypass; Ultrasound

Indexed keywords

BLOOD; FLOW MEASUREMENT; FLOWMETERS; HEART; HEMODYNAMICS; NANOCOMPOSITES; NON NEWTONIAN FLOW; PUMPS;

EID: 0033945071     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1525-1594.2000.06532.x     Document Type: Article
Times cited : (5)

References (10)
  • 2
    • 0030836465 scopus 로고    scopus 로고
    • Clinical importance of measuring coronary graft flows in the revascularized heart. Ultrasonic or electromagnetic?
    • 2. Canver C, Cooler S, Murray E, Nichols R, Heisey D. Clinical importance of measuring coronary graft flows in the revascularized heart. Ultrasonic or electromagnetic? J Cardiovasc Surg 1997;38:211-5.
    • (1997) J Cardiovasc Surg , vol.38 , pp. 211-215
    • Canver, C.1    Cooler, S.2    Murray, E.3    Nichols, R.4    Heisey, D.5
  • 4
    • 0030175390 scopus 로고    scopus 로고
    • Origin of the Doppler ultrasound spectrum from blood
    • 4. Bascom P, Cobbold R. Origin of the Doppler ultrasound spectrum from blood. IEEE Trans Biomedical Eng 1996; 43(6):562-71
    • (1996) IEEE Trans Biomedical Eng , vol.43 , Issue.6 , pp. 562-571
    • Bascom, P.1    Cobbold, R.2
  • 5
    • 0025500914 scopus 로고
    • The electronic detail of a pulsed Doppler blood flow measurement system
    • 5. Güler I, Güler N. The electronic detail of a pulsed Doppler blood flow measurement system. Meas Sci Tech 1990;1: 1087-92.
    • (1990) Meas Sci Tech , vol.1 , pp. 1087-1092
    • Güler, I.1    Güler, N.2
  • 6
    • 0024025604 scopus 로고
    • Comparison of zero-crossing counter to FFT spectrum of ultrasound Doppler
    • 6. Cote G, Fox M. Comparison of zero-crossing counter to FFT spectrum of ultrasound Doppler. IEEE Trans Biomed Eng 1988;35(6):498-502.
    • (1988) IEEE Trans Biomed Eng , vol.35 , Issue.6 , pp. 498-502
    • Cote, G.1    Fox, M.2
  • 7
    • 0023165156 scopus 로고
    • Spectral broadening in ultrasonic Doppler flowmeters due to unsteady flow
    • 7. Kikkawa S, Yamaguchi T, Tanishita K, Sugawara M. Spectral broadening in ultrasonic Doppler flowmeters due to unsteady flow. IEEE Trans Biomed Eng 1987;34(5):388-91.
    • (1987) IEEE Trans Biomed Eng , vol.34 , Issue.5 , pp. 388-391
    • Kikkawa, S.1    Yamaguchi, T.2    Tanishita, K.3    Sugawara, M.4
  • 8
    • 0027769402 scopus 로고
    • Cost/benefits criterion for selection of pulsed Doppler ultrasound spectral mean frequency and bandwidth estimators
    • 8. Ruano M, Fish P. Cost/benefits criterion for selection of pulsed Doppler ultrasound spectral mean frequency and bandwidth estimators. IEEE Trans Biomed Eng 1993;40(12): 1338-41.
    • (1993) IEEE Trans Biomed Eng , vol.40 , Issue.12 , pp. 1338-1341
    • Ruano, M.1    Fish, P.2
  • 9
    • 0026170582 scopus 로고
    • Modern spectral analysis techniques for blood flow velocity and spectral measurements with pulsed Doppler ultrasound
    • 9. David J, Jones S, Giddens D. Modern spectral analysis techniques for blood flow velocity and spectral measurements with pulsed Doppler ultrasound. IEEE Trans Biomed Eng 1991;38(5):589-96.
    • (1991) IEEE Trans Biomed Eng , vol.38 , Issue.5 , pp. 589-596
    • David, J.1    Jones, S.2    Giddens, D.3
  • 10
    • 8544268683 scopus 로고    scopus 로고
    • An automatic flow controller for a centrifugal blood pump
    • 10. Beppu T, et al. An automatic flow controller for a centrifugal blood pump. Artif Organs 1997;21(7):630-4.
    • (1997) Artif Organs , vol.21 , Issue.7 , pp. 630-634
    • Beppu, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.