메뉴 건너뛰기




Volumn 44, Issue 4, 1999, Pages 833-842

The use of GAFchromic film to determine the absolute activity of beta emitters

(3)  Fox, R A a   Barker, P a   Smart, G a  

a NONE

Author keywords

[No Author keywords available]

Indexed keywords

PHOSPHORUS 32; RADIOISOTOPE; RHENIUM 188; YTTRIUM 90;

EID: 0033006484     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/44/4/002     Document Type: Article
Times cited : (10)

References (10)
  • 3
    • 0031215184 scopus 로고    scopus 로고
    • Dosimetry of beta emitting radionuclides for use in balloon angioplasty
    • Fox R A 1997 Dosimetry of beta emitting radionuclides for use in balloon angioplasty Australas. Phys. Eng. Sci. Med. 20 139-46
    • (1997) Australas. Phys. Eng. Sci. Med. , vol.20 , pp. 139-146
    • Fox, R.A.1
  • 6
    • 0025307874 scopus 로고
    • EGS4 Monte Carlo determination of the beta dose kernel in water
    • Simpkin D J and Mackie T R 1990 EGS4 Monte Carlo determination of the beta dose kernel in water Med. Phys. 17 179-86
    • (1990) Med. Phys. , vol.17 , pp. 179-186
    • Simpkin, D.J.1    Mackie, T.R.2
  • 7
    • 0028845698 scopus 로고
    • Intra-arterial beta irradiation prevents neointimal hyperplasia in a hypercholesterolemic rabbit restenosis model
    • Verin V et al 1995 Intra-arterial beta irradiation prevents neointimal hyperplasia in a hypercholesterolemic rabbit restenosis model Circulation 92 2284-90
    • (1995) Circulation , vol.92 , pp. 2284-2290
    • Verin, V.1
  • 9
    • 0028799838 scopus 로고
    • Intracoronary low dose β-irradiation inhibits neointima formation after coronary artery balloon injury in the swine restenosis model
    • Waksman R, Robinson K A, Crocker I R, Wang C, Gravanis M B, Cipolla G D, Hillstead R A and King S B 1995a Intracoronary low dose β-irradiation inhibits neointima formation after coronary artery balloon injury in the swine restenosis model Circulation 92 3025-31
    • (1995) Circulation , vol.92 , pp. 3025-3031
    • Waksman, R.1    Robinson, K.A.2    Crocker, I.R.3    Wang, C.4    Gravanis, M.B.5    Cipolla, G.D.6    Hillstead, R.A.7    King, S.B.8
  • 10
    • 0031045089 scopus 로고    scopus 로고
    • Quantitative evaluation of radiochromic film response for two dimensional geometry
    • Zhu Y, Kirov A S, Mishra V, Meigooni A S and Williamson J F 1997 Quantitative evaluation of radiochromic film response for two dimensional geometry Med. Phys 24 223-31
    • (1997) Med. Phys , vol.24 , pp. 223-231
    • Zhu, Y.1    Kirov, A.S.2    Mishra, V.3    Meigooni, A.S.4    Williamson, J.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.