Volumn 25, Issue 5, 1997, Pages 779-785

Whole-body impedance cardiography in the measurement of cardiac output

Author keywords

Bioimpedance; Cardiac output; Hemodynamic monitoring; Impedance cardiography; Intensive care unit; Noninvasive diagnostics; Pulmonary artery catheter; Repeatability; Thermodilution; Whole body impedance cardiography

Indexed keywords

ADULT; ARTICLE; CARDIOGRAPHY; CLINICAL PROTOCOL; CLINICAL TRIAL; CORONARY ARTERY BYPASS GRAFT; DIAGNOSTIC ACCURACY; ELECTRODE; FEMALE; HEAD TILTING; HEART OUTPUT; HEMODYNAMIC MONITORING; HUMAN; IMPEDANCE; INTENSIVE CARE UNIT; MAJOR CLINICAL STUDY; MALE; OPERATING ROOM; PRIORITY JOURNAL; RELIABILITY; REPRODUCIBILITY; THERMODILUTION;

EID: 0030988157     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/00003246-199705000-00012     Document Type: Article
Times cited : (80)

References (36)
  • 1
    • 0013978742 scopus 로고
    • Development and evaluation of an impedance cardiac output system
    • Kubicek WG, Karnegis JN, Patterson RP, et al: Development and evaluation of an impedance cardiac output system. Aerospace Med 1966; 37:1208-1212
    • (1966) Aerospace Med , vol.37 , pp. 1208-1212
    • Kubicek, W.G.1    Karnegis, J.N.2    Patterson, R.P.3
  • 2
    • 0002305706 scopus 로고
    • Hemodynamic and pump performance monitoring by electrical bioimpedance: New concepts
    • Sramek BB: Hemodynamic and pump performance monitoring by electrical bioimpedance: New concepts. Problems in Respiratory Care 1989; 2: 274-290
    • (1989) Problems in Respiratory Care , vol.2 , pp. 274-290
    • Sramek, B.B.1
  • 3
    • 0015885524 scopus 로고
    • Estimation of the stroke volume by integral rheogram of the human body
    • Tishchenko MI: (Estimation of the stroke volume by integral rheogram of the human body.) [in Russian] Sechenov Physiol J 1973; 59:1216-1224
    • (1973) Sechenov Physiol J , vol.59 , pp. 1216-1224
    • Tishchenko, M.I.1
  • 4
    • 0017731260 scopus 로고
    • Experience in the use of integral rheography for the assessment of haemodynamic indices in emergencies in cardiology
    • Golikov AP, Berestov AA, Maiorov NI, et al: (Experience in the use of integral rheography for the assessment of haemodynamic indices in emergencies in cardiology.) [in Russian] Kardiologiia 1977; 17:54-58
    • (1977) Kardiologiia , vol.17 , pp. 54-58
    • Golikov, A.P.1    Berestov, A.A.2    Maiorov, N.I.3
  • 5
    • 0024676403 scopus 로고
    • On the accuracy of rheographic assessment of stroke volume
    • Zemtsovsky EV, Guseinov BA, Izvekova AV, et al: (On the accuracy of rheographic assessment of stroke volume.) [in Russian] Kardiologiia 1989; 29:75-79
    • (1989) Kardiologiia , vol.29 , pp. 75-79
    • Zemtsovsky, E.V.1    Guseinov, B.A.2    Izvekova, A.V.3
  • 6
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland MJ, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, M.J.1    Altman, D.G.2
  • 8
    • 0026639782 scopus 로고
    • The validity of cardiac output measurement by thoracic impedance: A meta-analysis
    • Fuller HD: The validity of cardiac output measurement by thoracic impedance: A meta-analysis. Clin Invest Med 1992; 15:103-112
    • (1992) Clin Invest Med , vol.15 , pp. 103-112
    • Fuller, H.D.1
  • 9
    • 0025990644 scopus 로고
    • Reliability of impedance cardiography in measuring central haemodynamics
    • Mehlsen J, Bonde J, Stadeager C, et al: Reliability of impedance cardiography in measuring central haemodynamics. Clin Physiol 1991; 11:579-588
    • (1991) Clin Physiol , vol.11 , pp. 579-588
    • Mehlsen, J.1    Bonde, J.2    Stadeager, C.3
  • 10
    • 0026651625 scopus 로고
    • Validity of cardiac output measurement by computer-averaged impedance cardiography, and comparison with simultaneous thermodilution determinations
    • Pickett BR, Buell JC: Validity of cardiac output measurement by computer-averaged impedance cardiography, and comparison with simultaneous thermodilution determinations. Am J Cardiol 1992; 69:1354-1358
    • (1992) Am J Cardiol , vol.69 , pp. 1354-1358
    • Pickett, B.R.1    Buell, J.C.2
  • 11
    • 0029003059 scopus 로고
    • Evaluation of impedance cardiography: Comparison of NCCOM3-R7 with Fick and thermodilution methods
    • Yakimets J, Jensen L: Evaluation of impedance cardiography: Comparison of NCCOM3-R7 with Fick and thermodilution methods. Heart Lung 1995; 24: 194-206
    • (1995) Heart Lung , vol.24 , pp. 194-206
    • Yakimets, J.1    Jensen, L.2
  • 12
    • 0029056066 scopus 로고
    • Cardiac output measurement: Lack of agreement between thermodilution and thoracic bioimpedance in two clinical settings
    • Atallah MM, Demain AT: Cardiac output measurement: Lack of agreement between thermodilution and thoracic bioimpedance in two clinical settings. J Clin Anesth 1995; 7:182-185
    • (1995) J Clin Anesth , vol.7 , pp. 182-185
    • Atallah, M.M.1    Demain, A.T.2
  • 13
    • 0028840609 scopus 로고
    • Comparison of cardiac output measurements by thermodilution and thoracic electrical bioimpedance in critically ill versus non-critically ill patients
    • Weiss S, Calloway E, Cairo J, et al: Comparison of cardiac output measurements by thermodilution and thoracic electrical bioimpedance in critically ill versus non-critically ill patients. Am J Emerg Med 1995; 13:626-631
    • (1995) Am J Emerg Med , vol.13 , pp. 626-631
    • Weiss, S.1    Calloway, E.2    Cairo, J.3
  • 14
    • 0029026354 scopus 로고
    • A review of impedance cardiography
    • Jensen L, Yakimets J, Teo KK: A review of impedance cardiography. Heart Lung 1995; 24:183-193
    • (1995) Heart Lung , vol.24 , pp. 183-193
    • Jensen, L.1    Yakimets, J.2    Teo, K.K.3
  • 16
    • 0024563766 scopus 로고
    • Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation
    • Cigarroa RG, Lange RA, Williams RH, et al: Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation. Am J Med 1989; 86:417-420
    • (1989) Am J Med , vol.86 , pp. 417-420
    • Cigarroa, R.G.1    Lange, R.A.2    Williams, R.H.3
  • 17
    • 0015684875 scopus 로고
    • Characteristics and clinical use of integral rheography. A new method of measuring of stroke volume
    • Tishchenko MI, Smirnov AD, Danilov LN, et al: Characteristics and clinical use of integral rheography. A new method of measuring of stroke volume, (in Russian) Kardiologiia 1973; 13: 54-62
    • (1973) Kardiologiia , vol.13 , pp. 54-62
    • Tishchenko, M.I.1    Smirnov, A.D.2    Danilov, L.N.3
  • 18
    • 0028914110 scopus 로고
    • Cardiac output during exercise measured by acetylene rebreathing, thermodilution, and Fick techniques
    • Hsia CCW, Herazo LF, Ramanathan M, et al: Cardiac output during exercise measured by acetylene rebreathing, thermodilution, and Fick techniques. J Appl Physiol 1995; 78:1612-1616
    • (1995) J Appl Physiol , vol.78 , pp. 1612-1616
    • Ccw, H.1    Herazo, L.F.2    Ramanathan, M.3
  • 20
    • 0022590888 scopus 로고
    • Method of assessing the reproducibility of blood flow measurement: Factors influencing the performance of thermodilution cardiac output computers
    • Mackenzie JD, Haites NE, Rawles JM: Method of assessing the reproducibility of blood flow measurement: Factors influencing the performance of thermodilution cardiac output computers. Br Heart J 1986; 55:14-24
    • (1986) Br Heart J , vol.55 , pp. 14-24
    • Mackenzie, J.D.1    Haites, N.E.2    Rawles, J.M.3
  • 21
    • 17644432572 scopus 로고
    • Thermodilution method overestimates low cardiac output in humans
    • Heart Circ Physiol 14
    • Van Grondelle A, Ditchey RV, Groves BM, et al: Thermodilution method overestimates low cardiac output in humans. Am J Physiol 1983; 245(Heart Circ Physiol 14):H690-H692
    • (1983) Am J Physiol , vol.245
    • Van Grondelle, A.1    Ditchey, R.V.2    Groves, B.M.3
  • 22
    • 84944367714 scopus 로고
    • Thermodilution cardiac output measurement. Effects of the respiratory cycle on its reproducibility
    • Stevens JH, Raffin TA, Mihm FG, et al: Thermodilution cardiac output measurement. Effects of the respiratory cycle on its reproducibility. JAMA 1985; 253: 2240-2242
    • (1985) JAMA , vol.253 , pp. 2240-2242
    • Stevens, J.H.1    Raffin, T.A.2    Mihm, F.G.3
  • 23
    • 0029153813 scopus 로고
    • The thermodilution method for the clinical assessment of cardiac output
    • Jansen JRC: The thermodilution method for the clinical assessment of cardiac output. Intensive Care Med 1995; 21:691-697
    • (1995) Intensive Care Med , vol.21 , pp. 691-697
    • Jansen, J.R.C.1
  • 24
    • 0022617227 scopus 로고
    • Improvement of cardiac output estimation by the thermodilution method during mechanical ventilation
    • Jansen JRC, Versprille A: Improvement of cardiac output estimation by the thermodilution method during mechanical ventilation. Intensive Care Med 1986; 12:71-79
    • (1986) Intensive Care Med , vol.12 , pp. 71-79
    • Jansen, J.R.C.1    Versprille, A.2
  • 25
    • 0029154767 scopus 로고
    • Continuous thermodilution cardiac output: Agreement with Fick and bolus thermodilution methods
    • Thrush D, Downs JB, Smith RA: Continuous thermodilution cardiac output: Agreement with Fick and bolus thermodilution methods. J Cardiothorac Vasc Anesth 1995; 9:399-404
    • (1995) J Cardiothorac Vasc Anesth , vol.9 , pp. 399-404
    • Thrush, D.1    Downs, J.B.2    Smith, R.A.3
  • 26
  • 27
    • 0028076648 scopus 로고
    • Oxygen Fick and modified carbon dioxide Fick cardiac outputs
    • Mahutte CK, Jaffe MB, Chen PA, et al: Oxygen Fick and modified carbon dioxide Fick cardiac outputs. Crit Care Med 1994; 22:86-95
    • (1994) Crit Care Med , vol.22 , pp. 86-95
    • Mahutte, C.K.1    Jaffe, M.B.2    Chen, P.A.3
  • 28
    • 0019349890 scopus 로고
    • Thoracic resistivity for stroke volume calculation in impedance cardiography
    • Quail AW, Traugott FM, Porges WL, et al: Thoracic resistivity for stroke volume calculation in impedance cardiography. J Appl Physiol 1981; 50:191-195
    • (1981) J Appl Physiol , vol.50 , pp. 191-195
    • Quail, A.W.1    Traugott, F.M.2    Porges, W.L.3
  • 29
    • 0019615281 scopus 로고
    • Evaluation of blood resistivity in vivo for impedance cardiography in man, dog and rabbit
    • Traugott FM, Quail AW, White SW: Evaluation of blood resistivity in vivo for impedance cardiography in man, dog and rabbit. Med Biol Eng Comput 1981; 19:547-552
    • (1981) Med Biol Eng Comput , vol.19 , pp. 547-552
    • Traugott, F.M.1    Quail, A.W.2    White, S.W.3
  • 30
    • 0028876909 scopus 로고
    • The influence of alternating current frequency on flow related admittance changes of blood: A concept for improvement of impedance cardiography
    • de Vries PMJM, Langendijk JWG, Kouw PM: The influence of alternating current frequency on flow related admittance changes of blood: A concept for improvement of impedance cardiography. Physiol Meas 1995; 16:63-69
    • (1995) Physiol Meas , vol.16 , pp. 63-69
    • Vries, P.M.J.M.1    Langendijk, J.W.G.2    Kouw, P.M.3
  • 31
    • 0022553636 scopus 로고
    • Validation of tetrapolar bioelectrical impedance method to assess human body composition
    • Lukaski HC, Bolonchuk WW, Hall CB, et al: Validation of tetrapolar bioelectrical impedance method to assess human body composition. J Appl Physiol 1986; 60:1327-1332
    • (1986) J Appl Physiol , vol.60 , pp. 1327-1332
    • Lukaski, H.C.1    Bolonchuk, W.W.2    Hall, C.B.3
  • 32
    • 0022980897 scopus 로고
    • A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale
    • Bernstein DP: A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale. Crit Care Med 1986; 14:904-909
    • (1986) Crit Care Med , vol.14 , pp. 904-909
    • Bernstein, D.P.1
  • 33
    • 0027412923 scopus 로고
    • Indicator amount, temperature, and intrinsic cardiac output affect thermodilution cardiac output accuracy and reproducibility
    • Renner LE, Morton MJ, Sakuma GY: Indicator amount, temperature, and intrinsic cardiac output affect thermodilution cardiac output accuracy and reproducibility. Circ Care Med 1993; 21: 586-597
    • (1993) Circ Care Med , vol.21 , pp. 586-597
    • Renner, L.E.1    Morton, M.J.2    Sakuma, G.Y.3
  • 34
    • 0027303341 scopus 로고
    • Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients
    • Sageman WS, Amundson DE: Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients. Crit Care Med 1993; 21:1139-1142
    • (1993) Crit Care Med , vol.21 , pp. 1139-1142
    • Sageman, W.S.1    Amundson, D.E.2
  • 35
    • 0028091134 scopus 로고
    • Intraoperative cardiac output monitoring: Comparison of impedance cardiography and thermodilution
    • Perrino AC, Lippman A, Ariyan C, et al: Intraoperative cardiac output monitoring: Comparison of impedance cardiography and thermodilution. J Cardiothor Vasc Anesth 1994; 8:24-29
    • (1994) J Cardiothor Vasc Anesth , vol.8 , pp. 24-29
    • Perrino, A.C.1    Lippman, A.2    Ariyan, C.3
  • 36
    • 0028839518 scopus 로고
    • Predictors of between-method differences in cardiac output measurement using thoracic electrical bioimpedance and thermodilution
    • Doering L, Lum E, Dracup K, et al: Predictors of between-method differences in cardiac output measurement using thoracic electrical bioimpedance and thermodilution. Crit Care Med 1995; 23:1667-1673
    • (1995) Crit Care Med , vol.23 , pp. 1667-1673
    • Doering, L.1    Lum, E.2    Dracup, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.