메뉴 건너뛰기




Volumn 62, Issue 3, 2000, Pages 190-198

Bulk-modified amperometric biosensors for hypoxanthine based on sol-gel technique

Author keywords

[No Author keywords available]

Indexed keywords

AMPEROMETRIC SENSORS; CERAMIC MATERIALS; ELECTROCHEMICAL ELECTRODES; GRAPHITE; MEATS; SILICA; SOL-GELS;

EID: 0033874999     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(99)00391-3     Document Type: Article
Times cited : (34)

References (41)
  • 1
    • 84985274583 scopus 로고
    • Lipase release from lysosomes of rainbow trout (Salmo Gairdneri) muscle subjected to low temperature
    • Geromel E.J., Motgomery M.W. Lipase release from lysosomes of rainbow trout (Salmo Gairdneri) muscle subjected to low temperature. J. Food Sci. 45:1980;412-415.
    • (1980) J. Food Sci. , vol.45 , pp. 412-415
    • Geromel, E.J.1    Motgomery, M.W.2
  • 3
    • 0342820886 scopus 로고
    • Post-mortem changes in glycogen, nucleotides, sugar phosphates, and sugars in fish muscles - A review
    • Tarr H.L.A. Post-mortem changes in glycogen, nucleotides, sugar phosphates, and sugars in fish muscles - a review. J. Food Sci. 31:1966;846-854.
    • (1966) J. Food Sci. , vol.31 , pp. 846-854
    • Tarr, H.L.A.1
  • 4
    • 84982338728 scopus 로고
    • Degradation of adenine- And hypoxanthine-nucleotide in the muscle of chill-stored trawled cod (Gadus callarias)
    • Jones N.R., Murray J. Degradation of adenine- and hypoxanthine-nucleotide in the muscle of chill-stored trawled cod (Gadus callarias). J. Sci. Food Agric. 13:1962;475-480.
    • (1962) J. Sci. Food Agric. , vol.13 , pp. 475-480
    • Jones, N.R.1    Murray, J.2
  • 5
    • 84981854050 scopus 로고
    • Nucleotide degradation in the muscle of iced haddock (Gadus aeglefinus), lemon sole (Pleuronectes platessa)
    • Kassemsarn B.-O., Sanz Perez B., Murray J., Jones N.R. Nucleotide degradation in the muscle of iced haddock (Gadus aeglefinus), lemon sole (Pleuronectes platessa). J. Food Sci. 28:1963;28-37.
    • (1963) J. Food Sci. , vol.28 , pp. 28-37
    • Kassemsarn, B.-O.1    Sanz Perez, B.2    Murray, J.3    Jones, N.R.4
  • 7
    • 0002136168 scopus 로고
    • Hypoxanthine: A biochemical index of fish quality
    • Burt J.R. Hypoxanthine: a biochemical index of fish quality. Process Biochem. 12:1977;32-35.
    • (1977) Process Biochem. , vol.12 , pp. 32-35
    • Burt, J.R.1
  • 8
    • 0025258551 scopus 로고
    • Determination of nucleotides in fish tissues using capillary electrophoresis
    • Nguyen A.L., Luong J.H.T., Masson C. Determination of nucleotides in fish tissues using capillary electrophoresis. Anal. Chem. 62:1990;2490-2493.
    • (1990) Anal. Chem. , vol.62 , pp. 2490-2493
    • Nguyen, A.L.1    Luong, J.H.T.2    Masson, C.3
  • 9
    • 0000034324 scopus 로고    scopus 로고
    • Development of a hypoxanthine biosensor based on immobilized xanthine oxidase chemically modified electrode
    • Hu S.S., Liu C.C. Development of a hypoxanthine biosensor based on immobilized xanthine oxidase chemically modified electrode. Electroanalysis. 9:1997;372-377.
    • (1997) Electroanalysis , vol.9 , pp. 372-377
    • Hu, S.S.1    Liu, C.C.2
  • 10
    • 0030371218 scopus 로고    scopus 로고
    • Enzyme sensors for determination of fish freshness
    • Volpe G., Mascini M. Enzyme sensors for determination of fish freshness. Talanta. 43:1996;283-289.
    • (1996) Talanta , vol.43 , pp. 283-289
    • Volpe, G.1    Mascini, M.2
  • 11
    • 0026632829 scopus 로고
    • Thin-film polyamine biosensor: Substrate specificity and application to fish freshness determination
    • Chemnitius G.C., Suzuki M., Isobe K., Kimura J., Karube I., Schmid R.D. Thin-film polyamine biosensor: substrate specificity and application to fish freshness determination. Anal. Chim. Acta. 263:1992;93-100.
    • (1992) Anal. Chim. Acta , vol.263 , pp. 93-100
    • Chemnitius, G.C.1    Suzuki, M.2    Isobe, K.3    Kimura, J.4    Karube, I.5    Schmid, R.D.6
  • 12
    • 0000702603 scopus 로고
    • Determination of hypoxanthine in fish meat with an enzyme sensor
    • Watanabe E., Ando K., Karube I., Matsuoka H., Suzuki S. Determination of hypoxanthine in fish meat with an enzyme sensor. J. Food Sci. 48:1983;496-500.
    • (1983) J. Food Sci. , vol.48 , pp. 496-500
    • Watanabe, E.1    Ando, K.2    Karube, I.3    Matsuoka, H.4    Suzuki, S.5
  • 13
    • 0001555556 scopus 로고
    • Simultaneous determination of hypoxanthine, inosine, inosine-5′-phosphate and adenosine-5′-phosphate with a multielectrode enzyme sensor
    • Watanabe E., Tokimatsu S., Toyama K., Karube I., Matsuoka H., Suzuki S. Simultaneous determination of hypoxanthine, inosine, inosine-5′-phosphate and adenosine-5′-phosphate with a multielectrode enzyme sensor. Anal. Chim. Acta. 164:1984;139-146.
    • (1984) Anal. Chim. Acta , vol.164 , pp. 139-146
    • Watanabe, E.1    Tokimatsu, S.2    Toyama, K.3    Karube, I.4    Matsuoka, H.5    Suzuki, S.6
  • 14
    • 0023079055 scopus 로고
    • Chemically immobilized bi-enzyme electrodes in the redox mediated mode for the flow injection analysis of glucose and hypoxanthine
    • Moody G.J., Sanghera G.S., Thomas J.D.R. Chemically immobilized bi-enzyme electrodes in the redox mediated mode for the flow injection analysis of glucose and hypoxanthine. Analyst. 112:1987;65-70.
    • (1987) Analyst , vol.112 , pp. 65-70
    • Moody, G.J.1    Sanghera, G.S.2    Thomas, J.D.R.3
  • 15
    • 0027514843 scopus 로고
    • Enzyme electrode for the successive detection of hypoxanthine and inosine
    • Yao T. Enzyme electrode for the successive detection of hypoxanthine and inosine. Anal. Chim. Acta. 281:1993;323-326.
    • (1993) Anal. Chim. Acta , vol.281 , pp. 323-326
    • Yao, T.1
  • 16
    • 0026102031 scopus 로고
    • Mediated amperometric biosensor for hypoxanthine based on a hydroxymethylferrocene-modified carbon paste electrode
    • Okuma H., Takahashi H., Sekimukai S., Kawahara K., Akahoshi R. Mediated amperometric biosensor for hypoxanthine based on a hydroxymethylferrocene-modified carbon paste electrode. Anal. Chim. Acta. 244:1991;161-164.
    • (1991) Anal. Chim. Acta , vol.244 , pp. 161-164
    • Okuma, H.1    Takahashi, H.2    Sekimukai, S.3    Kawahara, K.4    Akahoshi, R.5
  • 17
    • 0022960744 scopus 로고
    • Simultaneous determination of hypoxanthine and inosine with a enzyme sensor
    • Watanabe E., Endo H., Hayashi T., Toyama K. Simultaneous determination of hypoxanthine and inosine with a enzyme sensor. Biosensors. 2:1986;235-244.
    • (1986) Biosensors , vol.2 , pp. 235-244
    • Watanabe, E.1    Endo, H.2    Hayashi, T.3    Toyama, K.4
  • 18
    • 0000327428 scopus 로고    scopus 로고
    • Buttermilk based cobalt phthalocyanine dispersed ferricyanide mediated amperometric biosensor for the determination of xanthine
    • Kilinc E., Erdem A., Gokgunnec L., Dalbasti T., Karaoglan M., Ozsoz M. Buttermilk based cobalt phthalocyanine dispersed ferricyanide mediated amperometric biosensor for the determination of xanthine. Electroanalysis. 10:1998;273-275.
    • (1998) Electroanalysis , vol.10 , pp. 273-275
    • Kilinc, E.1    Erdem, A.2    Gokgunnec, L.3    Dalbasti, T.4    Karaoglan, M.5    Ozsoz, M.6
  • 19
    • 0030180705 scopus 로고    scopus 로고
    • Inert metal-modified, composite ceramic-carbon, amperometric biosensors: Renewable, controlled reactive layer
    • Sampath S., Lev O. Inert metal-modified, composite ceramic-carbon, amperometric biosensors: renewable, controlled reactive layer. Anal. Chem. 68:1996;2015-2021.
    • (1996) Anal. Chem. , vol.68 , pp. 2015-2021
    • Sampath, S.1    Lev, O.2
  • 20
    • 0001963312 scopus 로고    scopus 로고
    • Sol-gel-derived nanocrystalline gold-silicate composite biosensor
    • Bharathi S., Lev O. Sol-gel-derived nanocrystalline gold-silicate composite biosensor. Anal. Commun. 35:1998;29-31.
    • (1998) Anal. Commun. , vol.35 , pp. 29-31
    • Bharathi, S.1    Lev, O.2
  • 22
    • 0003310264 scopus 로고
    • The sol-gel process
    • Hench L.L., West J.K. The sol-gel process. Chem. Rev. 90:1990;33-72.
    • (1990) Chem. Rev. , vol.90 , pp. 33-72
    • Hench, L.L.1    West, J.K.2
  • 24
    • 0000469079 scopus 로고
    • Diagnostic applications of organically doped sol-gel porous glass
    • Lev O. Diagnostic applications of organically doped sol-gel porous glass. Analusis. 20:1992;543-553.
    • (1992) Analusis , vol.20 , pp. 543-553
    • Lev, O.1
  • 25
  • 26
    • 0000324041 scopus 로고
    • Organic chemistry within ceramic matrices: Doped sol-gel materials
    • Avnir D. Organic chemistry within ceramic matrices: doped sol-gel materials. Acc. Chem. Res. 28:1995;328-334.
    • (1995) Acc. Chem. Res. , vol.28 , pp. 328-334
    • Avnir, D.1
  • 27
    • 0031128409 scopus 로고    scopus 로고
    • Sol-gel glass as a matrix for chemical and biochemical sensing
    • Lin J., Brown C.W. Sol-gel glass as a matrix for chemical and biochemical sensing. Trends Anal. Chem. 16:1997;200-211.
    • (1997) Trends Anal. Chem. , vol.16 , pp. 200-211
    • Lin, J.1    Brown, C.W.2
  • 28
    • 0002202341 scopus 로고    scopus 로고
    • Renewable-surface graphite-ceramic enzyme sensors for the determination of hypoxanthine in fish meat
    • Niu J., Lee J.-Y. Renewable-surface graphite-ceramic enzyme sensors for the determination of hypoxanthine in fish meat. Anal. Commun. 36:1999;81-83.
    • (1999) Anal. Commun. , vol.36 , pp. 81-83
    • Niu, J.1    Lee, J.-Y.2
  • 29
    • 0001183517 scopus 로고    scopus 로고
    • Screen-printable sol-gel enzyme-containing carbon inks
    • Wang J., Pamidi P.V.A., Park D.S. Screen-printable sol-gel enzyme-containing carbon inks. Anal. Chem. 68:1996;2705-2708.
    • (1996) Anal. Chem. , vol.68 , pp. 2705-2708
    • Wang, J.1    Pamidi, P.V.A.2    Park, D.S.3
  • 30
    • 58149365208 scopus 로고
    • Sol-gel derived renewable-surface biosensors
    • Pankratov I., Lev O. Sol-gel derived renewable-surface biosensors. J. Electroanal. Chem. 393:1995;35-41.
    • (1995) J. Electroanal. Chem. , vol.393 , pp. 35-41
    • Pankratov, I.1    Lev, O.2
  • 31
    • 0031143767 scopus 로고    scopus 로고
    • Mediated amperometric glucose sensor modified by sol-gel method
    • Li J., Chia L.S., Goh N.K., Tan S.N., Ge H. Mediated amperometric glucose sensor modified by sol-gel method. Sens. Actuators, B. 40:1997;135-141.
    • (1997) Sens. Actuators, B , vol.40 , pp. 135-141
    • Li, J.1    Chia, L.S.2    Goh, N.K.3    Tan, S.N.4    Ge, H.5
  • 32
    • 0026068611 scopus 로고
    • Amperometric sensor for hypoxanthine and xanthine based on the detection of uric acid
    • Gonzalez E., Pariente F., Lorenzo E., Hernandez L. Amperometric sensor for hypoxanthine and xanthine based on the detection of uric acid. Anal. Chim. Acta. 242:1991;267-273.
    • (1991) Anal. Chim. Acta , vol.242 , pp. 267-273
    • Gonzalez, E.1    Pariente, F.2    Lorenzo, E.3    Hernandez, L.4
  • 33
    • 0024327528 scopus 로고
    • Development and application of a biosensor for hypoxanthine in fish extract
    • Mulchandani A., Luong J.H.T., Male K.B. Development and application of a biosensor for hypoxanthine in fish extract. Anal. Chim. Acta. 221:1989;215-222.
    • (1989) Anal. Chim. Acta , vol.221 , pp. 215-222
    • Mulchandani, A.1    Luong, J.H.T.2    Male, K.B.3
  • 34
    • 0001541608 scopus 로고    scopus 로고
    • Sol-gel derived gold composite electrodes
    • Wang J., Pamidi P.V.A. Sol-gel derived gold composite electrodes. Anal. Chem. 69:1997;4490-4494.
    • (1997) Anal. Chem. , vol.69 , pp. 4490-4494
    • Wang, J.1    Pamidi, P.V.A.2
  • 36
    • 0030579569 scopus 로고    scopus 로고
    • Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide
    • Li J., Tan S.N., Ge H. Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide. Anal. Chim. Acta. 335:1996;137-145.
    • (1996) Anal. Chim. Acta , vol.335 , pp. 137-145
    • Li, J.1    Tan, S.N.2    Ge, H.3
  • 39
    • 84982343479 scopus 로고
    • Rapid estimation of hypoxanthine concentrations as indices of the freshness of chill-stored fish
    • Jones N.R., Murray J., Livingston E.I., Murray C.K. Rapid estimation of hypoxanthine concentrations as indices of the freshness of chill-stored fish. J. Sci. Food Agric. 15:1964;763-774.
    • (1964) J. Sci. Food Agric. , vol.15 , pp. 763-774
    • Jones, N.R.1    Murray, J.2    Livingston, E.I.3    Murray, C.K.4
  • 40
    • 37049095884 scopus 로고
    • Recommended general methods for the examination of fish and fish products
    • Recommended general methods for the examination of fish and fish products. Analyst. 104:1979;434-450.
    • (1979) Analyst , vol.104 , pp. 434-450


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.