Volumn 10, Issue 5, 1999, Pages 841-844

Magnetic resonance-guided vascular catheterization: Feasibility using a passive tracking technique at 0.2 Telsa in a pig model

Author keywords

Device tracking; Fast magnetic resonance imaging; Interventional magnetic resonance imaging; Magnetic resonance angiography; True FISP; Vascular interventions

Indexed keywords

GADOLINIUM PENTETATE;

EID: 0032708185     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2586(199911)10:5<841::AID-JMRI32>3.0.CO;2-P     Document Type: Article
Times cited : (23)

References (22)
  • 1
    • 0027399141 scopus 로고
    • Real-time position monitoring of invasive devices using magnetic resonance
    • Dumoulin CL, Souza SP, Darrow RD. Real-time position monitoring of invasive devices using magnetic resonance. Magn Reson Med 1993;29:411-415.
    • (1993) Magn Reson Med , vol.29 , pp. 411-415
    • Dumoulin, C.L.1    Souza, S.P.2    Darrow, R.D.3
  • 5
    • 0031228548 scopus 로고    scopus 로고
    • Klassische interventionelle Radiologie und interventionelle MRT: Chancen und Zukunftsperspektiven
    • Vorwerk D, Adam G. Klassische interventionelle Radiologie und interventionelle MRT: Chancen und Zukunftsperspektiven. Fortschr Rontgenstr 1997;167:216-218.
    • (1997) Fortschr Rontgenstr , vol.167 , pp. 216-218
    • Vorwerk, D.1    Adam, G.2
  • 6
    • 0030949007 scopus 로고    scopus 로고
    • Kathetervisualisierung in der MR-tomographie: Erste tierexperimentelle erfahrungen mit feldinhomogenitätskathetern
    • Adam G, Glowinski A, Neuerburg J, Bucker A, van Vaals JJ, Hurtak W, Gunther RW. Kathetervisualisierung in der MR-Tomographie: erste tierexperimentelle Erfahrungen mit Feldinhomogenitätskathetern. Rofo Fortschr 1997;166:324-328.
    • (1997) Rofo Fortschr , vol.166 , pp. 324-328
    • Adam, G.1    Glowinski, A.2    Neuerburg, J.3    Bucker, A.4    Van Vaals, J.J.5    Hurtak, W.6    Gunther, R.W.7
  • 7
    • 0031934692 scopus 로고    scopus 로고
    • Visualization of MR-compatible catheters by electrically induced local field inhomogeneities: Evaluation in vivo
    • Adam G, Glowinski A, Neuerburg J, Bucker A, van Vaals JJ, Gunther RW. Visualization of MR-compatible catheters by electrically induced local field inhomogeneities: evaluation in vivo. J Magn Reson Imaging 1998;8:209-213.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 209-213
    • Adam, G.1    Glowinski, A.2    Neuerburg, J.3    Bucker, A.4    Van Vaals, J.J.5    Gunther, R.W.6
  • 9
    • 0031828890 scopus 로고    scopus 로고
    • Aktive instrumentenführung in der interventionellen MR-tomographie: Einführung in ein neues konzept
    • Wildermuth S, Erhart, P, Leung DA, Göhde S, Schoenenberger A, Debatin JF. Aktive Instrumentenführung in der interventionellen MR-Tomographie: Einführung in ein neues Konzept. Fortschr Röntgenstr 1998;169:77-84.
    • (1998) Fortschr Röntgenstr , vol.169 , pp. 77-84
    • Wildermuth, S.1    Leung, D.A.2    Göhde, S.3    Schoenenberger, A.4    Debatin, J.F.5
  • 13
    • 0031012185 scopus 로고    scopus 로고
    • MR-guided endovascular interventions: Susceptibility-based catheter and near-real-time imaging technique
    • Bakker CJ, Hoogeveen RM, Hurtak WF, van Vaals JJ, Viergever MA, Mali WP. MR-guided endovascular interventions: susceptibility-based catheter and near-real-time imaging technique. Radiology 1997;202:273-276.
    • (1997) Radiology , vol.202 , pp. 273-276
    • Bakker, C.J.1    Hoogeveen, R.M.2    Hurtak, W.F.3    Van Vaals, J.J.4    Viergever, M.A.5    Mali, W.P.6
  • 15
  • 16
    • 0031848729 scopus 로고    scopus 로고
    • A rapid 2D time-resolved variable-rate k-space sampling MR technique for passive catheter tracking during endovascular procedures
    • Unal O, Korosec FR, Frayne R, Strother CM, Mistretta CA. A rapid 2D time-resolved variable-rate k-space sampling MR technique for passive catheter tracking during endovascular procedures. Magn Reson Med 1998;40:356-362.
    • (1998) Magn Reson Med , vol.40 , pp. 356-362
    • Unal, O.1    Korosec, F.R.2    Frayne, R.3    Strother, C.M.4    Mistretta, C.A.5
  • 19
    • 0029896023 scopus 로고    scopus 로고
    • Needle localization in MR-guided biopsy and aspiration: Effects of field strength, sequence design, and magnetic field orientation
    • Lewin JS, Duerk JL, Jain VR, Petersilge CA, Chao CP, Haaga JR. Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. Am J Roentgenol 1996;166:1337-1345.
    • (1996) Am J Roentgenol , vol.166 , pp. 1337-1345
    • Lewin, J.S.1    Duerk, J.L.2    Jain, V.R.3    Petersilge, C.A.4    Chao, C.P.5    Haaga, J.R.6
  • 20
    • 0031884958 scopus 로고    scopus 로고
    • Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at 0.2 T
    • Duerk JL, Lewin JS, Wendt M, Petersilge C. Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at 0.2 T. J Magn Reson Imaging 1998;8:203-208.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 203-208
    • Duerk, J.L.1    Lewin, J.S.2    Wendt, M.3    Petersilge, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.