메뉴 건너뛰기




Volumn 38, Issue 12, 1999, Pages 1758-1761

A method for high-throughput screening of enantioselective catalysts

Author keywords

Asymmetric catalysis; Combinatorial chemistry; Enzyme catalysis; High throughput screening; Mass spectrometry

Indexed keywords

ARTICLE; CATALYST; CHEMICAL REACTION; ENANTIOMER; HYDROLYSIS; ISOTOPE LABELING; MASS SPECTROMETRY;

EID: 0033553835     PISSN: 14337851     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1521-3773(19990614)38:12<1758::AID-ANIE1758>3.0.CO;2-8     Document Type: Article
Times cited : (322)

References (47)
  • 5
    • 0000860751 scopus 로고    scopus 로고
    • Combinatorial chemistry
    • c) Chem. Rev. 1997, 97, 347-510 (special issue on combinatorial chemistry);
    • (1997) Chem. Rev. , vol.97 , Issue.SPEC. ISSUE , pp. 347-510
  • 15
    • 0032544378 scopus 로고    scopus 로고
    • Angew. Chem. Int. Ed. 1998, 37, 2333-2336;
    • (1998) Angew. Chem. Int. Ed. , vol.37 , pp. 2333-2336
  • 17
    • 33747537300 scopus 로고    scopus 로고
    • Angew. Chem. Int. Ed. 1998, 57, 2644-2647;
    • (1998) Angew. Chem. Int. Ed. , vol.57 , pp. 2644-2647
  • 19
    • 33747567037 scopus 로고    scopus 로고
    • Angew. Chem. Int. Ed. 1998, 57, 3369-3372;
    • (1998) Angew. Chem. Int. Ed. , vol.57 , pp. 3369-3372
  • 21
    • 0001064205 scopus 로고    scopus 로고
    • j) T. Bein, Angew. Chem. 1999, 111, 335-338;
    • (1999) Angew. Chem. , vol.111 , pp. 335-338
    • Bein, T.1
  • 32
    • 33747559275 scopus 로고    scopus 로고
    • Angew. Chem. Int. Ed. 1998, 37, 2547-2650.
    • (1998) Angew. Chem. Int. Ed. , vol.37 , pp. 2547-2650
  • 34
    • 26844440137 scopus 로고
    • (Eds.: E. R. Garrett, J. L. Hirtz), Dekker, New York
    • pseudo-Enantiomers are chiral compounds which differ in two respects only: opposite absolute configuration and isotopic labeling. A 1:1 mixture of such compounds has been called a pseudo-racemate (B. Testa, P. Jenner in Drug Fate and Metabolism: Methods and Techniques, Vol. 2 (Eds.: E. R. Garrett, J. L. Hirtz), Dekker, New York, 1978, p. 143), but this has been declared a misnomer
    • (1978) Drug Fate and Metabolism: Methods and Techniques , vol.2 , pp. 143
    • Testa, B.1    Jenner, P.2
  • 36
    • 0025334187 scopus 로고
    • Horeau et al. have described the application of MS to the detection of isotopically labeled diastereomers, prepared by the reaction of a compound of unknown configuration with an excess of a 1:1 mixture of isotopically labeled pseudo-enantiomers: a) A. Horeau, A. Nouaille, Tetrahedron Lett. 1990, 31, 2707-2710; other use of pseudo-enantiomers:
    • (1990) Tetrahedron Lett. , vol.31 , pp. 2707-2710
    • Horeau, A.1    Nouaille, A.2
  • 42
    • 33747560279 scopus 로고    scopus 로고
    • note
    • [9a] to the determination of ee values in high-throughput screening. However, this requires an additional step (derivatization) and an excess of a 1:1 mixture of the pseudo-enantiomeric reagent as well as the assumption that conversion is complete without any enrichment of one of the diastereomers.
  • 45
    • 33747542866 scopus 로고    scopus 로고
    • note
    • +, Figure 1). The ratios of the peak intensities (and thus the ee values of the synthetic mixtures of 15 and 16) were obtained automatically using a macro to submit the data from the m/z intensity table of each measurement to an Excel spread sheet.
  • 46
    • 33747562154 scopus 로고    scopus 로고
    • note
    • All enzyme-catalyzed hydrolytic reactions and esterifications were performed in deep-well microtiter plates (total volume 1.2 mL). For ESI-MS analysis a defined volume of the resulting product mixtures was extracted with diethyl ether. The extracts were automatically transferred in microtiter plates and diluted with methanol to a final concentration of 0.5-2.0 mM. The microtiter plates were placed in an automated sample manager (Scheme 2) equipped with a Rheodyne port for the injections.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.