메뉴 건너뛰기




Volumn 37, Issue 6, 1999, Pages 673-679

Colonoscopy aided by magnetic 3D imaging: Is the technique sufficiently sensitive to detect differences between men and women?

Author keywords

3D computerised magnetic imaging; Colonoscopy; Male female differences in colonic length; Stiffening overtube

Indexed keywords

COMPUTER AIDED DIAGNOSIS; ENDOSCOPY; GASTROENTEROLOGY; THREE DIMENSIONAL COMPUTER GRAPHICS;

EID: 0033372550     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02513366     Document Type: Article
Times cited : (20)

References (27)
  • 1
    • 0032912247 scopus 로고    scopus 로고
    • The reach of flexible sigmoidoscopy - Not enough?
    • BAILLIE, J. (1999): 'The reach of flexible sigmoidoscopy - not enough?', Endoscopy 31, pp. 269-270
    • (1999) Endoscopy , vol.31 , pp. 269-270
    • Baillie, J.1
  • 2
    • 0032855624 scopus 로고    scopus 로고
    • Colonoscopy aided by magnetic 3D imaging: Assessment of the routine use of a stiffening tube to speed up the procedure
    • BELL, G. D., ROWLAND, R. S., RUTTER, M., ABU-SADA, M., DOGRAMADZI, S., and ALLEN, C. (1999a): 'Colonoscopy aided by magnetic 3D imaging: assessment of the routine use of a stiffening tube to speed up the procedure', Med. Biol. Eng. Comput., 37, pp. 605-611
    • (1999) Med. Biol. Eng. Comput. , vol.37 , pp. 605-611
    • Bell, G.D.1    Rowland, R.S.2    Rutter, M.3    Abu-Sada, M.4    Dogramadzi, S.5    Allen, C.6
  • 3
    • 85038067081 scopus 로고    scopus 로고
    • Preliminary experience comparing two longer thinner prototype olympus endoscopes with a standard 60 cm flexible sigmoidoscope
    • BELL, G. D., PAINTER, J., ROWLAND, R. S., ATKIN, W. S., DOGRAMADZI, S., and ALLEN, C. (1999b): 'Preliminary experience comparing two longer thinner prototype Olympus endoscopes with a standard 60 cm flexible sigmoidoscope', Gut, 44, (suppl. 1), p. A22
    • (1999) Gut , vol.44 , Issue.SUPPL. 1
    • Bell, G.D.1    Painter, J.2    Rowland, R.S.3    Atkin, W.S.4    Dogramadzi, S.5    Allen, C.6
  • 4
    • 0027410418 scopus 로고
    • Non-radiological technique for three dimensional imaging of intestinal endoscopes
    • BLADEN, J. S., Anderson, A. P., BELL, G. D., RAMEH, B., and EVANS, B. (1993): 'Non-radiological technique for three dimensional imaging of intestinal endoscopes', Lancet, 341, pp. 719-722
    • (1993) Lancet , vol.341 , pp. 719-722
    • Bladen, J.S.1    Anderson, A.P.2    Bell, G.D.3    Rameh, B.4    Evans, B.5
  • 6
    • 85038059681 scopus 로고    scopus 로고
    • A new variable-stiffness colonoscope makes insertion quicker and may reduce patient discomfort
    • BROOKER, J. C., SAUNDERS, B. P., and WILLIAMS, C. B. (1999): 'A new variable-stiffness colonoscope makes insertion quicker and may reduce patient discomfort', Gut, 44, (suppl 1), p. A21
    • (1999) Gut , vol.44 , Issue.SUPPL. 1
    • Brooker, J.C.1    Saunders, B.P.2    Williams, C.B.3
  • 7
    • 85038056684 scopus 로고
    • DAVIES, D. V., and DAVIES, F. (Eds.): (University Press, Glasgow)
    • GRAY (1962): DAVIES, D. V., and DAVIES, F. (Eds.): 'Gray's anatomy. 33rd edn.' (University Press, Glasgow), pp. 1457-1471
    • (1962) Gray's Anatomy. 33rd Edn. , pp. 1457-1471
    • Gray1
  • 9
    • 0343772867 scopus 로고
    • Colonoscopy intubation techniques with fluoroscopy-8.4.2 the sigmoid splint/stiffening sleeve
    • HUNT, R. H., and WAYE, J. D. (Eds.): (Chapman and Hall Ltd, London, ISBN 0 412 22710X), chap. 8
    • HUNT, R. H. (1981): 'Colonoscopy intubation techniques with fluoroscopy-8.4.2 The sigmoid splint/stiffening sleeve' in HUNT, R. H., and WAYE, J. D. (Eds.): 'Colonoscopy techniques, clinical practice and colour atlas' (Chapman and Hall Ltd, London, ISBN 0 412 22710X), chap. 8, pp. 128-130
    • (1981) Colonoscopy Techniques, Clinical Practice and Colour Atlas , pp. 128-130
    • Hunt, R.H.1
  • 10
    • 0030476990 scopus 로고    scopus 로고
    • Use of a pediatric colonoscope improves the success of total colonoscopy in selected adult patients
    • MARSHALL, J. B. (1996): 'Use of a pediatric colonoscope improves the success of total colonoscopy in selected adult patients', Gastrointest. Endosc., 44, pp. 675-678
    • (1996) Gastrointest. Endosc. , vol.44 , pp. 675-678
    • Marshall, J.B.1
  • 11
    • 0028127772 scopus 로고
    • Screening for colorectal cancer by nurse endoscopists
    • MAULE, W. F. (1994): 'Screening for colorectal cancer by nurse endoscopists', N. Engl. J. Med., 330, pp. 183-187
    • (1994) N. Engl. J. Med. , vol.330 , pp. 183-187
    • Maule, W.F.1
  • 12
    • 0032032856 scopus 로고    scopus 로고
    • A device for measuring the forces exerted on the shaft of an endoscope during colonoscopy
    • MOSSE, C. A., MILLS, T. N., BELL, G. D., and SWAIN, P. (1998): 'A device for measuring the forces exerted on the shaft of an endoscope during colonoscopy', Med. Biol. Eng. Comput., 36, pp. 186-190
    • (1998) Med. Biol. Eng. Comput. , vol.36 , pp. 186-190
    • Mosse, C.A.1    Mills, T.N.2    Bell, G.D.3    Swain, P.4
  • 14
    • 0032942131 scopus 로고    scopus 로고
    • Depth of insertion at flexible sigmoidoscopy: Implications for colorectal cancer screening and instrument design
    • PAINTER, J., SAUNDERS, D. B., BELL, G. D., WILLIAMS, C. B., PITT, R., and BLADEN, J. (1999): 'Depth of insertion at flexible sigmoidoscopy: implications for colorectal cancer screening and instrument design', Endoscopy, 31, pp. 227-231
    • (1999) Endoscopy , vol.31 , pp. 227-231
    • Painter, J.1    Saunders, D.B.2    Bell, G.D.3    Williams, C.B.4    Pitt, R.5    Bladen, J.6
  • 15
    • 0032078167 scopus 로고    scopus 로고
    • Non-radiological technique for 3D imaging of intestinal endoscopes: Computerised graphical 3d representation of endoscope and skeleton
    • ROWLAND, R. S., and BELL, G. D. (1998): 'Non-radiological technique for 3D imaging of intestinal endoscopes: computerised graphical 3D representation of endoscope and skeleton', Med. Biol. Eng. Comput., 36, pp. 285-290
    • (1998) Med. Biol. Eng. Comput. , vol.36 , pp. 285-290
    • Rowland, R.S.1    Bell, G.D.2
  • 16
    • 0342901977 scopus 로고    scopus 로고
    • Validation of a 3-D method of accurately measuring the insertion depth of different anatomical sections of the colon during flexible endoscopy
    • ROWLAND, R. S., BELL, G. D., DOGRAMADZI, S., and ALLEN, C. (1999): 'Validation of a 3-D method of accurately measuring the insertion depth of different anatomical sections of the colon during flexible endoscopy', Gut, 44, (suppl 1), p. A 22
    • (1999) Gut , vol.44 , Issue.SUPPL. 1
    • Rowland, R.S.1    Bell, G.D.2    Dogramadzi, S.3    Allen, C.4
  • 17
    • 0026492549 scopus 로고
    • Analysis of length and surface area of each segment of the large intestine according to age, sex, and physique
    • SADAHIRO, S., OHMURA, T., and YAMADA, Y. (1992): 'Analysis of length and surface area of each segment of the large intestine according to age, sex, and physique', Surg. Radiol. Anat., 14, pp. 251-257
    • (1992) Surg. Radiol. Anat. , vol.14 , pp. 251-257
    • Sadahiro, S.1    Ohmura, T.2    Yamada, Y.3
  • 18
    • 0002234383 scopus 로고
    • Techniques in colonoscopy
    • SIVAK, M., Jr. (Ed.): (W. B. Saunders, Philadelphia)
    • SAKAI, Y. (1987):'Techniques in colonoscopy' in SIVAK, M., Jr. (Ed.): 'Gastroenterological endoscopy' (W. B. Saunders, Philadelphia), pp. 840-867
    • (1987) Gastroenterological Endoscopy , pp. 840-867
    • Sakai, Y.1
  • 19
    • 0029075023 scopus 로고
    • First clinical results with a real-time, electronic imager as an aid to colonoscopy
    • SAUNDERS, B. P., BLADEN, J. S., WILLIAMS, C. B., and BELL, G. D. (1995a): 'First clinical results with a real-time, electronic imager as an aid to colonoscopy', Gut, 36, pp. 913-917
    • (1995) Gut , vol.36 , pp. 913-917
    • Saunders, B.P.1    Bladen, J.S.2    Williams, C.B.3    Bell, G.D.4
  • 20
    • 0028784355 scopus 로고
    • Intraoperative measurements of colonic anatomy and attachments with relevance to colonoscopy
    • SAUNDERS, B. P., PHILIPS, R. K. S., and WILLIAMS, C. B. (1995b): 'Intraoperative measurements of colonic anatomy and attachments with relevance to colonoscopy', Br. J. Surg., 82, pp. 1491-1493
    • (1995) Br. J. Surg. , vol.82 , pp. 1491-1493
    • Saunders, B.P.1    Philips, R.K.S.2    Williams, C.B.3
  • 22
  • 24
    • 0027477890 scopus 로고
    • Electronic three-dimensional imaging of intestinal endoscopy
    • WILLIAMS, C. B., GUY, C., GILLIES, D. F., and SAUNDERS, B. P. (1993): 'Electronic three-dimensional imaging of intestinal endoscopy', Lancet, 341, pp. 724-725
    • (1993) Lancet , vol.341 , pp. 724-725
    • Williams, C.B.1    Guy, C.2    Gillies, D.F.3    Saunders, B.P.4
  • 25
    • 85038052173 scopus 로고    scopus 로고
    • Colonoscopy and flexible sigmoidoscopy-handling the colonoscope
    • COTTON, P. B., and WILLIAMS, C. B. (Eds.): (Blackwell Science Ltd., Oxford, ISBN 0-86542-851-4), chap. 9
    • WILLIAMS, C. B. (1996a): 'Colonoscopy and flexible sigmoidoscopy-Handling the colonoscope' in COTTON, P. B., and WILLIAMS, C. B. (Eds.): 'Practical gastrointestinal endoscopy, 4th edn.' (Blackwell Science Ltd., Oxford, ISBN 0-86542-851-4), chap. 9, pp. 215-217
    • (1996) Practical Gastrointestinal Endoscopy, 4th Edn. , pp. 215-217
    • Williams, C.B.1
  • 26
    • 0343337018 scopus 로고    scopus 로고
    • Colonoscopy and flexible sigmoidoscopy -the stiffening or 'overtube'
    • COTTON, P. B., and WILLIAMS, C. B. (Eds.): (Blackwell Science Ltd., Oxford, ISBN 0-86542-851-4), chap. 9
    • WILLIAMS, C. B. (1996b): 'Colonoscopy and flexible sigmoidoscopy -The stiffening or 'overtube' in COTTON, P. B., and WILLIAMS, C. B. (Eds.): 'Practical gastrointestinal endoscopy, 4th edn.' (Blackwell Science Ltd., Oxford, ISBN 0-86542-851-4), chap. 9, pp. 246-247
    • (1996) Practical Gastrointestinal Endoscopy, 4th Edn. , pp. 246-247
    • Williams, C.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.