메뉴 건너뛰기




Volumn 36, Issue 4, 1998, Pages 475-479

Colonoscope flexural rigidity measurement

Author keywords

Colonoscopes; Column buckling; Endoscopes; Flexural rigidity

Indexed keywords

DEFORMATION; EQUIPMENT TESTING; STIFFNESS;

EID: 0032128167     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02523217     Document Type: Article
Times cited : (24)

References (12)
  • 2
    • 0022620159 scopus 로고
    • Efficacy of routine fiberoptic endoscope cleaning and disinfection for killing clostridium
    • HUGHES, C. E., GEBHARD, R. L., PETERSON, L. R., GERDING, D. N. (1986): 'Efficacy of routine fiberoptic endoscope cleaning and disinfection for killing clostridium', Gastrointestinal Endoscopy, 32, pp. 7-9
    • (1986) Gastrointestinal Endoscopy , vol.32 , pp. 7-9
    • Hughes, C.E.1    Gebhard, R.L.2    Peterson, L.R.3    Gerding, D.N.4
  • 3
    • 0023551325 scopus 로고
    • Color performance of video endoscopes: Quantitative measurement of color reproduction
    • KNYRIM, K., SEIDLITZ, H. K., HAGENMÜLLER, F., and CLASSEN, M. (1987): 'Color performance of video endoscopes: quantitative measurement of color reproduction', Endoscopy, 19, pp. 233-6
    • (1987) Endoscopy , vol.19 , pp. 233-236
    • Knyrim, K.1    Seidlitz, H.K.2    Hagenmüller, F.3    Classen, M.4
  • 4
    • 0030476990 scopus 로고    scopus 로고
    • Use of a pediatric colonoscope improves the success of total colonoscopy in selected adult patients
    • MARSHALL, J. B. (1996): 'Use of a pediatric colonoscope improves the success of total colonoscopy in selected adult patients', Gastrointestinal Endoscopy, 44, pp. 675-678
    • (1996) Gastrointestinal Endoscopy , vol.44 , pp. 675-678
    • Marshall, J.B.1
  • 5
    • 0021520155 scopus 로고
    • Investigation of the flexural and torsional rigidity of flexible elements of endoscopes
    • NEMIROVSKII, M. E., and KUZIMIN, A. I. (1985): 'Investigation of the flexural and torsional rigidity of flexible elements of endoscopes', Biomed. Eng., 18, pp. 213-217, Also in (1984) Meditsinkaia Tekhnika, 6, pp. 31-34
    • (1985) Biomed. Eng. , vol.18 , pp. 213-217
    • Nemirovskii, M.E.1    Kuzimin, A.I.2
  • 6
    • 0346794918 scopus 로고
    • NEMIROVSKII, M. E., and KUZIMIN, A. I. (1985): 'Investigation of the flexural and torsional rigidity of flexible elements of endoscopes', Biomed. Eng., 18, pp. 213-217, Also in (1984) Meditsinkaia Tekhnika, 6, pp. 31-34
    • (1984) Meditsinkaia Tekhnika , vol.6 , pp. 31-34
  • 7
    • 0004253043 scopus 로고
    • Prentice-Hall, Englewood Cliffs, New Jersey
    • POPOV, E. P. (1976): 'Mechanics of materials', 2nd edn. (Prentice-Hall, Englewood Cliffs, New Jersey), pp. 463-465
    • (1976) 'Mechanics of Materials', 2nd Edn. , pp. 463-465
    • Popov, E.P.1
  • 8
    • 0027076228 scopus 로고
    • Variability in reprocessing policies and procedures for flexible fiberoptic endoscopes in Massachusetts hospitals
    • REYNOLDS, C. D., RHINEHART, E., DREYER, P., and GOLDMANN, D. A. (1992): 'Variability in reprocessing policies and procedures for flexible fiberoptic endoscopes in Massachusetts hospitals', Am. J. Infection Contr., 20, pp. 283-290
    • (1992) Am. J. Infection Contr. , vol.20 , pp. 283-290
    • Reynolds, C.D.1    Rhinehart, E.2    Dreyer, P.3    Goldmann, D.A.4
  • 9
    • 0002234383 scopus 로고
    • Techniques of colonoscopy
    • SIVAK, M., JR. (Ed.): W. B. Saunders, Philadelphia
    • SAKAI, Y. (1987): 'Techniques of colonoscopy' in SIVAK, M., JR. (Ed.): 'Gastroenterologic endoscopy' (W. B. Saunders, Philadelphia), pp. 840-867
    • (1987) Gastroenterologic Endoscopy , pp. 840-867
    • Sakai, Y.1
  • 10
    • 0026520245 scopus 로고
    • Optical resolution and color performance of electronic endoscopes
    • SEIDLITZ, H. K. and CLASSEN, M. (1992): 'Optical resolution and color performance of electronic endoscopes', Endoscopy, 24, pp. 225-228
    • (1992) Endoscopy , vol.24 , pp. 225-228
    • Seidlitz, H.K.1    Classen, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.