-
1
-
-
0002989262
-
-
Paul, J. P. Forces transmitted by joints in the human body. Proc. Instn Mech. Engrs, Part H, Journal of Engineering in Medicine, 1967, 181(37), 8-15.
-
(1967)
Forces Transmitted by Joints in the Human Body. Proc. Instn Mech. Engrs, Part H, Journal of Engineering in Medicine
, vol.181
, Issue.37
, pp. 8-15
-
-
Paul, J.P.1
-
2
-
-
0029421292
-
-
(H4), 233-241.
-
Hall, R., Unsworth, A., Craig, P., Hardaker, C, Sincy, P. and Wroblewski, B. Measurement of wear in retrieved acetabular sockets. Proc. Instn Mech. Engrs, Part H, Journal of Engineering in Medicine, 1995, 209(H4), 233-241.
-
Unsworth, A., Craig, P., Hardaker, C, Sincy, P. and Wroblewski, B. Measurement of Wear in Retrieved Acetabular Sockets. Proc. Instn Mech. Engrs, Part H, Journal of Engineering in Medicine
, vol.1995
, pp. 209
-
-
Hall, R.1
-
4
-
-
0030560772
-
-
Good, V., Clarke, I. and Anissian, L. Water and bovine serum lubrication compared in simulator PTFE/CoCr wear model. J. Biomed. Mater. Res. (Appl. Biomater.), 1996, 33, 275-283.
-
(1996)
Clarke, I. and Anissian, L. Water and Bovine Serum Lubrication Compared in Simulator PTFE/CoCr Wear Model. J. Biomed. Mater. Res. (Appl. Biomater.)
, vol.33
, pp. 275-283
-
-
Good, V.1
-
5
-
-
0014457406
-
-
Charnley, J., Kamanger, A. and Longfield, M. The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip. Med. Biol Engng, 1969,7,31.
-
(1969)
Kamanger, A. and Longfield, M. the Optimum Size of Prosthetic Heads in Relation to the Wear of Plastic Sockets in Total Replacement of the Hip. Med. Biol Engng
, vol.7
, pp. 31
-
-
Charnley, J.1
-
6
-
-
0024040573
-
-
Dowson, D. and Jobbins, B. Design and development of a versatile hip joint simulator and a preliminary assessment of the wear and creep in Charnley total replacement hip joints. Engng Med., 1988, 17(3), 111-117.
-
(1988)
And Jobbins, B. Design and Development of a Versatile Hip Joint Simulator and a Preliminary Assessment of the Wear and Creep in Charnley Total Replacement Hip Joints. Engng Med.
, vol.17
, Issue.3
, pp. 111-117
-
-
Dowson, D.1
-
7
-
-
0027015657
-
-
(H4), 195-200.
-
Saikko, V., Paavolainen, P., Kleimola, M. and Slatis, P. A five station hip joint simulator for wear rate studies. Proc. Instn Mech. Engrs, Part II, Journal of Engineering in Medicine, 1992, 206(H4), 195-200.
-
(1992)
Paavolainen, P., Kleimola, M. and Slatis, P. a Five Station Hip Joint Simulator for Wear Rate Studies. Proc. Instn Mech. Engrs, Part II, Journal of Engineering in Medicine
, pp. 206
-
-
Saikko, V.1
-
8
-
-
0028439173
-
-
Derbyshire, B., Fisher, J., Dowson, D., Hardaker, C. and Brummitt, K. Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints. Med. Engng Phys., 1994, 16, 229-236.
-
(1994)
Fisher, J., Dowson, D., Hardaker, C. and Brummitt, K. Comparative Study of the Wear of UHMWPE with Zirconia Ceramic and Stainless Steel Femoral Heads in Artificial Hip Joints. Med. Engng Phys.
, vol.16
, pp. 229-236
-
-
Derbyshire, B.1
-
10
-
-
0022108301
-
-
Atkinson, J. R., Dowson, D., Isaac, G. H. and Wroblewski, B. M. A microscopical study of the surfaces of Charnley Polyethylene acetabular sockets. Wear, 1985,104, 217-224.
-
(1985)
Dowson, D., Isaac, G. H. and Wroblewski, B. M. a Microscopical Study of the Surfaces of Charnley Polyethylene Acetabular Sockets. Wear
, vol.104
, pp. 217-224
-
-
Atkinson, J.R.1
-
12
-
-
0026506655
-
-
Isaac, G., Wroblcwski, B., Atkinson, J. and Dowson, D. A tribological study of retrieved hip prostheses. Clin. Orthop., 1992,276, 115-125.
-
(1992)
Wroblcwski, B., Atkinson, J. and Dowson, D. a Tribological Study of Retrieved Hip Prostheses. Clin. Orthop.
, vol.276
, pp. 115-125
-
-
Isaac, G.1
-
13
-
-
0027407506
-
-
Kabo, J., Gebhard, S., Loren, G. and Amstutz, H. In vivo wear of polyethylene acetabular components. J. Bone Jt Surg., 1993, 75B, 254-258.
-
(1993)
Gebhard, S., Loren, G. and Amstutz, H. in Vivo Wear of Polyethylene Acetabular Components. J. Bone Jt Surg.
, vol.75 B
, pp. 254-258
-
-
Kabo, J.1
-
14
-
-
0028448404
-
-
Hall, R., Unsworth, A., Wroblcwski, B. and Burgess, I. Frictional characterisation of explanted Charnley hip prostheses. Wear, 1994, 175, 159-166.
-
(1994)
Unsworth, A., Wroblcwski, B. and Burgess, I. Frictional Characterisation of Explanted Charnley Hip Prostheses. Wear
, vol.175
, pp. 159-166
-
-
Hall, R.1
|