메뉴 건너뛰기




Volumn 47, Issue 3, 1999, Pages 210-214

Effect of a confocal pinhole in two-photon microscopy

Author keywords

Fluorescence; Resolution; Second harmonic generation

Indexed keywords

FLUORESCENCE; HARMONIC ANALYSIS; NONLINEAR OPTICS; PHOTONS; SAPPHIRE;

EID: 0033230841     PISSN: 1059910X     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-0029(19991101)47:3<210::AID-JEMT7>3.0.CO;2-H     Document Type: Article
Times cited : (36)

References (11)
  • 1
    • 0025342635 scopus 로고
    • Two-photon laser scanning fluorescence microscopy
    • Denk W, Strickler JH, Webb WW. 1990. Two-photon laser scanning fluorescence microscopy. Science 248:73-76.
    • (1990) Science , vol.248 , pp. 73-76
    • Denk, W.1    Strickler, J.H.2    Webb, W.W.3
  • 2
    • 0018018945 scopus 로고
    • Second harmonic imaging in the scanning optical microscope
    • Gannaway J, Sheppard CJR. 1978. Second harmonic imaging in the scanning optical microscope. Opt Quantum Elect 10:435-439.
    • (1978) Opt Quantum Elect , vol.10 , pp. 435-439
    • Gannaway, J.1    Sheppard, C.J.R.2
  • 3
    • 0032606450 scopus 로고    scopus 로고
    • Effect of a finite-size pinhole on noise performance in single-, two-and three-photon confocal fluorescence microscopy
    • Gauderon R, Sheppard CJR. 1999. Effect of a finite-size pinhole on noise performance in single-, two-and three-photon confocal fluorescence microscopy. Appl Optics 38:3562-3565.
    • (1999) Appl Optics , vol.38 , pp. 3562-3565
    • Gauderon, R.1    Sheppard, C.J.R.2
  • 4
    • 0032134733 scopus 로고    scopus 로고
    • Three-dimensional second-harmonic generation imaging with femtosecond laser pulses
    • Gauderon R, Lukins PB, Sheppard CJR. 1998. Three-dimensional second-harmonic generation imaging with femtosecond laser pulses. Optics Lett 23:1209-1211.
    • (1998) Optics Lett , vol.23 , pp. 1209-1211
    • Gauderon, R.1    Lukins, P.B.2    Sheppard, C.J.R.3
  • 5
    • 0030498107 scopus 로고    scopus 로고
    • Effect of the detector size and the fluorescence wavelength on the resolution of three-and two-photon confocal microscopy
    • Gu M, Gan XS. 1996. Effect of the detector size and the fluorescence wavelength on the resolution of three-and two-photon confocal microscopy. Bioimaging 4:129-137.
    • (1996) Bioimaging , vol.4 , pp. 129-137
    • Gu, M.1    Gan, X.S.2
  • 6
    • 0028924632 scopus 로고
    • Comparison of three-dimensional imaging properties between two-photon and single-photon fluorescence microscopy
    • Gu M, Sheppard CJR. 1995. Comparison of three-dimensional imaging properties between two-photon and single-photon fluorescence microscopy. J Microsc 177:128-137.
    • (1995) J Microsc , vol.177 , pp. 128-137
    • Gu, M.1    Sheppard, C.J.R.2
  • 8
    • 0031667172 scopus 로고    scopus 로고
    • 3D microscopy of transparent objects using third-harmonic generation
    • Mueller M, Squier J, Wilson KR, Brakenhoff GJ. 1998. 3D microscopy of transparent objects using third-harmonic generation. J Microsc 191:266-274.
    • (1998) J Microsc , vol.191 , pp. 266-274
    • Mueller, M.1    Squier, J.2    Wilson, K.R.3    Brakenhoff, G.J.4
  • 11
    • 0018693571 scopus 로고
    • Imaging and super-resolution in the harmonic microscope
    • Wilson T, Sheppard CJR. 1979. Imaging and super-resolution in the harmonic microscope. Optica Acta 26:761-770.
    • (1979) Optica Acta , vol.26 , pp. 761-770
    • Wilson, T.1    Sheppard, C.J.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.