Flash Dent: An alternative charge-coupled device/scintillator-based direct digital intraoral radiographie system
-
Scarfe WC, Farman AG, Kelly MS. Flash Dent: an alternative charge-coupled device/scintillator-based direct digital intraoral radiographie system. Dentomaxillofac Radiol 1994;23:11-7.
-
(1994)
Dentomaxillofac Radiol
, vol.23
, pp. 11-17
-
-
Scarfe, W.C.1
Farman, A.G.2
Kelly, M.S.3
-
3
-
-
0027064977
-
Sens-A-Ray: A new system for direct digital intraoral radiography
-
Nelvig P, Wing K, Welander U. Sens-A-Ray: a new system for direct digital intraoral radiography. Oral Surg Oral Med Oral Pathol 1992;74:818-23.
-
(1992)
Oral Surg Oral Med Oral Pathol
, vol.74
, pp. 818-823
-
-
Nelvig, P.1
Wing, K.2
Welander, U.3
-
4
-
-
0039192706
-
Visualix, a new system for direct dental x-ray imaging: A preliminary report
-
Molteni R. Visualix, a new system for direct dental x-ray imaging: a preliminary report. Dentomaxillofac Radiol 1992;21:222-3.
-
(1992)
Dentomaxillofac Radiol
, vol.21
, pp. 222-223
-
-
Molteni, R.1
-
5
-
-
0029101782
-
Beam quality and image contrast with the VIXA-2
-
Hayakawa Y, Farman AG, Scarfe WC, Kuroyanagi K, Molteni R. Beam quality and image contrast with the VIXA-2. Oral Radiol 1995;11:31-6.
-
(1995)
Oral Radiol
, vol.11
, pp. 31-36
-
-
Hayakawa, Y.1
Farman, A.G.2
Scarfe, W.C.3
Kuroyanagi, K.4
Molteni, R.5
-
6
-
-
0029313035
-
Computed dental radiogaphy: Evaluation of a new charge-coupled device-based intraoral radiographic system
-
Farman AG, Scarfe WC, Schick DB, Rumack PM. Computed dental radiogaphy: evaluation of a new charge-coupled device-based intraoral radiographic system. Quintessence International 1995;26:399-404.
-
(1995)
Quintessence International
, vol.26
, pp. 399-404
-
-
Farman, A.G.1
Scarfe, W.C.2
Schick, D.B.3
Rumack, P.M.4
-
7
-
-
84886670836
-
Active pixel sensors: Are CCD's dinosaurs?
-
Possum ER. Active pixel sensors: Are CCD's dinosaurs? Proc SPIE 1993;1900:2-14.
-
(1993)
Proc SPIE
, vol.1900
, pp. 2-14
-
-
Possum, E.R.1
-
8
-
-
0003908115
-
Medical imaging - The assessment of image quality
-
Bethesda, Md: International Commission on Radiation Units and Measurements; 1996 Apr.
-
Medical imaging - the assessment of image quality. Bethesda, Md: International Commission on Radiation Units and Measurements; 1996 Apr. ICRU Report No. 54.
-
ICRU Report No. 54.
, vol.54
-
-
-
9
-
-
0027304121
-
Detector response and exposure control of the RadioVisioGraphy system (RVG 32000 ZHR)
-
Chen S-K, Hollender L. Detector response and exposure control of the RadioVisioGraphy system (RVG 32000 ZHR). Oral Surg Oral Med Oral Pathol 1993;76:104-11.
-
(1993)
Oral Surg Oral Med Oral Pathol
, vol.76
, pp. 104-111
-
-
Chen, S.-K.1
Hollender, L.2
-
10
-
-
0029335931
-
Sens-A-Ray characteristics with variations in beam quality
-
Harada T, Nishikawa K, Shibuya H, Hayakawa Y, Kuroyanagi K. Sens-A-Ray characteristics with variations in beam quality. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1995;80:120-3.
-
(1995)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.80
, pp. 120-123
-
-
Harada, T.1
Nishikawa, K.2
Shibuya, H.3
Hayakawa, Y.4
Kuroyanagi, K.5
-
12
-
-
0028486714
-
Intraoral computed radiography using Fuji computed radiography image plate: Correlation between image quality and reading condition
-
Kashima I, Sakurai T, Matsuki T, Nakamura K, Aoki H, Ishii M, et al. Intraoral computed radiography using Fuji computed radiography image plate: correlation between image quality and reading condition. Oral Surg Oral Med Oral Pathol 1994;78:239-46.
-
(1994)
Oral Surg Oral Med Oral Pathol
, vol.78
, pp. 239-246
-
-
Kashima, I.1
Sakurai, T.2
Matsuki, T.3
Nakamura, K.4
Aoki, H.5
Ishii, M.6
-
13
-
-
0028472831
-
Resolution as defined by line spread and modulation transfer functions for four digital intraoral radiographic systems
-
Welander U, McDavid WD, Sanderink GCH, Tronje G, Mörner AC, Dove B. Resolution as defined by line spread and modulation transfer functions for four digital intraoral radiographic systems. Oral Surg Oral Med Oral Pathol 1994;78:109-15.
-
(1994)
Oral Surg Oral Med Oral Pathol
, vol.78
, pp. 109-115
-
-
Welander, U.1
McDavid, W.D.2
Sanderink, G.C.H.3
Tronje, G.4
Mörner, A.C.5
Dove, B.6
-
14
-
-
0027421769
-
35-mm film scanner as an intraoral dental radiograph digitizer: A quantitative evaluation
-
Shrout M, Potter BJ, Yurgalavage HM, Hildebolt CF, Vannier W. 35-mm film scanner as an intraoral dental radiograph digitizer: a quantitative evaluation. Oral Surg Oral Med Oral Pathol 1993;76:502-9.
-
(1993)
Oral Surg Oral Med Oral Pathol
, vol.76
, pp. 502-509
-
-
Shrout, M.1
Potter, B.J.2
Yurgalavage, H.M.3
Hildebolt, C.F.4
Vannier, W.5
-
15
-
-
0019913387
-
A practical method to measure the MTF of CT scanners
-
Droege RT, Morin RL. A practical method to measure the MTF of CT scanners. Med Phys 1982;9:758-60.
-
(1982)
Med Phys
, vol.9
, pp. 758-760
-
-
Droege, R.T.1
Morin, R.L.2
-
16
-
-
0020571694
-
A practical method to routinely monitor resolution in digital images
-
Droege RT. A practical method to routinely monitor resolution in digital images. Med Phys 1983;10:337-43.
-
(1983)
Med Phys
, vol.10
, pp. 337-343
-
-
Droege, R.T.1
-
17
-
-
0027224067
-
Direct digital x-ray imaging with Visualix/Vixa
-
Moltini R. Direct digital x-ray imaging with Visualix/Vixa. Oral Surg Oral Med Oral Pathol 1993;76:235-43.
-
(1993)
Oral Surg Oral Med Oral Pathol
, vol.76
, pp. 235-243
-
-
Moltini, R.1
-
18
-
-
0028471403
-
Image quality of direct digital intraoral x-ray sensors in assessing root canal length: The RadioVisioGraphy, Visualix/Vixa, Se-A-Ray and Flash Dent systems compared to Ektaspeed films
-
Sanderink GCH, Huiskens R, van der Stell PF, Welander US, Stheeman SE. Image quality of direct digital intraoral x-ray sensors in assessing root canal length: the RadioVisioGraphy, Visualix/Vixa, Se-A-Ray and Flash Dent systems compared to Ektaspeed films. Oral Surg Oral Med Oral Pathol 1994;78:125-32.
-
(1994)
Oral Surg Oral Med Oral Pathol
, vol.78
, pp. 125-132
-
-
Sanderink, G.C.H.1
Huiskens, R.2
Van Der Stell, P.F.3
Welander, U.S.4
Stheeman, S.E.5
-
19
-
-
0031610927
-
Digital radiography and caries diagnosis
-
Wenzel A. Digital radiography and caries diagnosis. Dentomaxillofac Radiol 1998;27:3-11.
-
(1998)
Dentomaxillofac Radiol
, vol.27
, pp. 3-11
-
-
Wenzel, A.1
-
20
-
-
0030112207
-
On the dynamic range of different x-ray photon detectors in intra-oral radiography. a comparison of image quality in film, charge-coupled device and storage phosphor systems
-
Borg E, Gröndahl H-G. On the dynamic range of different x-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems. Dentomaxillofac Radiol 1996;25:82-8.
-
(1996)
Dentomaxillofac Radiol
, vol.25
, pp. 82-88
-
-
Borg, E.1
Gröndahl, H.-G.2
-
22
-
-
0028103666
-
Sensor noise in direct digital imaging (the RadioVisioGraphy, Sens-A-Ray, and Visualix/Vixa systems) evaluated by subtraction radiography
-
Wenzel A. Sensor noise in direct digital imaging (the RadioVisioGraphy, Sens-A-Ray, and Visualix/Vixa systems) evaluated by subtraction radiography. Oral Surg Oral Med Oral Pathol 1994;77:70-4.
-
(1994)
Oral Surg Oral Med Oral Pathol
, vol.77
, pp. 70-74
-
-
Wenzel, A.1
-
23
-
-
0025136283
-
Effects of various noise sources on the detective quantum efficiency of phosphor screens
-
Nishikawa RM, Yaffe MJ. Effects of various noise sources on the detective quantum efficiency of phosphor screens. Med Phys 1990;17:887-93.
-
(1990)
Med Phys
, vol.17
, pp. 887-893
-
-
Nishikawa, R.M.1
Yaffe, M.J.2
-
24
-
-
0030112138
-
Optimum exposure ranges for computed dental radiography
-
Hayakwa Y, Farman AG, Scarfe WC, Kuroyanagi K, Rumack PM, Schick DB. Optimum exposure ranges for computed dental radiography. Dentomaxillofac Radiol 1996;25:71-5.
-
(1996)
Dentomaxillofac Radiol
, vol.25
, pp. 71-75
-
-
Hayakwa, Y.1
Farman, A.G.2
Scarfe, W.C.3
Kuroyanagi, K.4
Rumack, P.M.5
Schick, D.B.6
-
25
-
-
0027639474
-
An evaluation of the Sens-A-Ray digital dental imaging system
-
McDonnell D, Price C. An evaluation of the Sens-A-Ray digital dental imaging system. Dentomaxillofac Radiol 1993;22:121-6.
-
(1993)
Dentomaxillofac Radiol
, vol.22
, pp. 121-126
-
-
McDonnell, D.1
Price, C.2
-
26
-
-
0030225854
-
Diagnostic accuracy of direct digital dental radiography for the detection of periapical bone lesions
-
Kullendorff B, Nilsson M, Rohlin M. Diagnostic accuracy of direct digital dental radiography for the detection of periapical bone lesions. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1996;82:344-50.
-
(1996)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.82
, pp. 344-350
-
-
Kullendorff, B.1
Nilsson, M.2
Rohlin, M.3
-
27
-
-
0030622248
-
Detecting small mass differences with a direct digital dental x-ray system
-
Chen SK, Hollender L, Omnell K-Å. Detecting small mass differences with a direct digital dental x-ray system. Dentomaxillofac Radiol 1997;26:63-6.
-
(1997)
Dentomaxillofac Radiol
, vol.26
, pp. 63-66
-
-
Chen, S.K.1
Hollender, L.2
Omnell, K.-Å.3
-
28
-
-
0029401048
-
Computed radiography with photostimulable phosphor in oral and maxillofacial radiology
-
Kashima I. Computed radiography with photostimulable phosphor in oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1995;80:277-98.
-
(1995)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.80
, pp. 277-298
-
-
Kashima, I.1
|