-
1
-
-
0030110849
-
Bone response to surface-modified titanium implants: Studies on the early tissue response to machined and electropolished implants with different oxide thickness
-
[1] Larsson C, Thomsen P, Aronsson BO, et al. Bone response to surface-modified titanium implants: studies on the early tissue response to machined and electropolished implants with different oxide thickness. Biomaterials 1996;17:605-16.
-
(1996)
Biomaterials
, vol.17
, pp. 605-616
-
-
Larsson, C.1
Thomsen, P.2
Aronsson, B.O.3
-
2
-
-
0025900565
-
Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs
-
[2] Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res 1991;25:889-902.
-
(1991)
J Biomed Mater Res
, vol.25
, pp. 889-902
-
-
Buser, D.1
Schenk, R.K.2
Steinemann, S.3
Fiorellini, J.P.4
Fox, C.H.5
Stich, H.6
-
3
-
-
0029379901
-
2 blasted, ha-coated, and machined implants: An experimental study with rabbits
-
2 blasted, HA-coated, and machined implants: an experimental study with rabbits. J Biomed Mater Res 1995;29:1223-31.
-
(1995)
J Biomed Mater Res
, vol.29
, pp. 1223-1231
-
-
Gotfredsen, K.1
Wennerberg, A.2
Johansson, C.3
Skovgaárd, L.T.4
Hjørting-Hansen, E.5
-
4
-
-
0029681619
-
Bone tissue response to commercially pure titanium implants blasted with fine and coarse particles of aluminum oxide
-
[4] Wennerberg A, Albrektsson T, Andersson B. Bone tissue response to commercially pure titanium implants blasted with fine and coarse particles of aluminum oxide. Int J Oral Maxillofac Implants 1996;11:38-45.
-
(1996)
Int J Oral Maxillofac Implants
, vol.11
, pp. 38-45
-
-
Wennerberg, A.1
Albrektsson, T.2
Andersson, B.3
-
5
-
-
0029268053
-
A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies
-
[5] Wennerberg A, Albrektsson T, Andersson B, Krol JJ. A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies. Clin Oral Implants Res 1995;6:24-30.
-
(1995)
Clin Oral Implants Res
, vol.6
, pp. 24-30
-
-
Wennerberg, A.1
Albrektsson, T.2
Andersson, B.3
Krol, J.J.4
-
6
-
-
0028230087
-
The influence of a hydroxyapatite and tricalciumphosphate coating on bone growth into titanium fiber-metal implants
-
[6] Tisel CL, Goldberg VM, Parr JA, Bensusan JS, Stikoff LS, Stevenson S. The influence of a hydroxyapatite and tricalciumphosphate coating on bone growth into titanium fiber-metal implants. J Bone Joint Surg A 1994;76:139-71.
-
(1994)
J Bone Joint Surg A
, vol.76
, pp. 139-171
-
-
Tisel, C.L.1
Goldberg, V.M.2
Parr, J.A.3
Bensusan, J.S.4
Stikoff, L.S.5
Stevenson, S.6
-
7
-
-
0026599431
-
Enhanced ingrowth of porous-coated cocr implants plasmaspray with tricalcium phosphate
-
[7] Chae JC, Collier JP, Mayer MB, Surprenant VA, Dauphinais LA. Enhanced ingrowth of porous-coated CoCr implants plasmaspray with tricalcium phosphate. J Biomed Mater Res 1992; 56:93-102.
-
(1992)
J Biomed Mater Res
, vol.56
, pp. 93-102
-
-
Chae, J.C.1
Collier, J.P.2
Mayer, M.B.3
Surprenant, V.A.4
Dauphinais, L.A.5
-
8
-
-
0026594550
-
Bone graft incorporation around titanium alloy and hydroxyapatite coated implants in dogs
-
[8] Søballe K, Hansen ES, Brockstedt-Rasmussen H, Pedersen CM, Bunger C. Bone graft incorporation around titanium alloy and hydroxyapatite coated implants in dogs. Clin Orthop Rel Res 1992;274:282-93.
-
(1992)
Clin Orthop Rel Res
, vol.274
, pp. 282-293
-
-
Søballe, K.1
Hansen, E.S.2
Brockstedt-Rasmussen, H.3
Pedersen, C.M.4
Bunger, C.5
-
9
-
-
0023499767
-
Chemical implant fixation using hydroxyl-apatite coatings
-
[9] Geesink RGT, de Groot K, Klein CPAT. Chemical implant fixation using hydroxyl-apatite coatings. Clin Orthop 1987;225: 147-70.
-
(1987)
Clin Orthop
, vol.225
, pp. 147-170
-
-
Geesink, R.G.T.1
De Groot, K.2
Klein, C.P.A.T.3
-
10
-
-
0026015759
-
Plasma-sprayed coatings of tetracalciumphosphate, hydroxylapatite and alpha-tcp on titanium allow: An interface study
-
[10] Klein CPAT, Patka P, van der Lubbe HBM, Wolke JGC, de Groot K. Plasma-sprayed coatings of tetracalciumphosphate, hydroxylapatite and alpha-TCP on titanium allow: an interface study. J Biomed Mater Res 1991;25:53-65.
-
(1991)
J Biomed Mater Res
, vol.25
, pp. 53-65
-
-
Klein, C.P.A.T.1
Patka, P.2
Van Der Lubbe, H.B.M.3
Wolke, J.G.C.4
De Groot, K.5
-
11
-
-
33644966618
-
Bioactive calcium phosphate coating prepared by electrodeposition
-
[11] Shirkhanzadeh M. Bioactive calcium phosphate coating prepared by electrodeposition. J Mater Sci Lett 1991;10:1415-7.
-
(1991)
J Mater Sci Lett
, vol.10
, pp. 1415-1417
-
-
Shirkhanzadeh, M.1
-
12
-
-
0031195163
-
Mechanical and histologic evaluation of ca-p plasma-spray and magnetron sputter-coated implants in trabecular bone of the goat
-
[12] Hulshoff JEG, Hayakawa T, van Dijk K, Leijdekkers-Govers AFM, van der Waerden JPCM, Jansen JA. Mechanical and histologic evaluation of Ca-P plasma-spray and magnetron sputter-coated implants in trabecular bone of the goat. J Biomed Mater Res 1997;36:75-83.
-
(1997)
J Biomed Mater Res
, vol.36
, pp. 75-83
-
-
Hulshoff, J.E.G.1
Hayakawa, T.2
Van Dijk, K.3
Leijdekkers-Govers, A.F.M.4
Van Der Waerden, J.P.C.M.5
Jansen, J.A.6
-
13
-
-
0002788239
-
Bone healing along the ca-P coated implants by ion-beam-assisted sputter deposition method in rabbit tibiae. Ca/P composition and bone healing
-
4-7 September Goteborg, Sweden
-
[13] Tsuboi Y, Sennerby L, Johansson C, Albrektsson T, Ektessabi AM, Iizuka T. Bone healing along the Ca-P coated implants by ion-beam-assisted sputter deposition method in rabbit tibiae. Ca/P composition and bone healing. 13th European Conference on Biomaterials, European Society for Biomaterials, 4-7 September 1997, Goteborg, Sweden. p. 121.
-
(1997)
13th European Conference on Biomaterials, European Society for Biomaterials
, pp. 121
-
-
Tsuboi, Y.1
Sennerby, L.2
Johansson, C.3
Albrektsson, T.4
Ektessabi, A.M.5
Iizuka, T.6
-
15
-
-
0028912877
-
Formation and characterization of anodic titanium oxide films containing ca and p
-
[15] Ishizawa H, Ogino M. Formation and characterization of anodic titanium oxide films containing Ca and P. J Biomed Mater Res 1995;29:65-72.
-
(1995)
J Biomed Mater Res
, vol.29
, pp. 65-72
-
-
Ishizawa, H.1
Ogino, M.2
-
16
-
-
0031148694
-
Histomorphometric evaluation of the thin hydroxyapatite layer formed through anodization followed by hydrothermal treatment
-
[16] Ishizawa H, Fujino M, Ogino M. Histomorphometric evaluation of the thin hydroxyapatite layer formed through anodization followed by hydrothermal treatment. J Biomed Mater Res 1997; 35:199-206.
-
(1997)
J Biomed Mater Res
, vol.35
, pp. 199-206
-
-
Ishizawa, H.1
Fujino, M.2
Ogino, M.3
-
17
-
-
0029395023
-
Mechanical and histological investigation of hydrothermally treated and untreated anodic titanium oxide films containing Ca and P
-
[17] Ishizawa H, Fujino M, Ogino M. Mechanical and histological investigation of hydrothermally treated and untreated anodic titanium oxide films containing Ca and P. J Biomed Mater Res 1995;29:1459-68.
-
(1995)
J Biomed Mater Res
, vol.29
, pp. 1459-1468
-
-
Ishizawa, H.1
Fujino, M.2
Ogino, M.3
-
18
-
-
0030200493
-
Biocompatibility studies on glass ionomer cements by primary cultures of human osteoblasts
-
[18] Oliva A, Della Ragione F, Salerno A, et al. Biocompatibility studies on glass ionomer cements by primary cultures of human osteoblasts. Biomaterials 1996;17:1351-6.
-
(1996)
Biomaterials
, vol.17
, pp. 1351-1356
-
-
Oliva, A.1
Della Ragione, F.2
Salerno, A.3
-
19
-
-
0009574503
-
Quantitative investigations of titanium implants in bone
-
4-7 September Goteborg, Sweden
-
[19] Johansson CB, Heo SJ, Meredith N, Wennerberg A, Albrektsson T. Quantitative investigations of titanium implants in bone. 13th European Conference on Biomaterials, European Society for Biomaterials, 4-7 September 1997, Goteborg, Sweden. p. 46.
-
(1997)
13th European Conference on Biomaterials, European Society for Biomaterials
, pp. 46
-
-
Johansson, C.B.1
Heo, S.J.2
Meredith, N.3
Wennerberg, A.4
Albrektsson, T.5
-
20
-
-
0000514548
-
Bone response to hydroxyapatite-coated and commercially pure titanium implants in the human arthritic knee
-
[20] Carlsson L, Regnér L, Johansson C, Gottlander M, Herberts P. Bone response to hydroxyapatite-coated and commercially pure titanium implants in the human arthritic knee. J Bone Joint Surg 1994;6:274-85.
-
(1994)
J Bone Joint Surg
, vol.6
, pp. 274-285
-
-
Carlsson, L.1
Regnér, L.2
Johansson, C.3
Gottlander, M.4
Herberts, P.5
-
21
-
-
0028096039
-
Remodelling of bone around hydroxyapatite and titanium in experimental osteoporosis
-
[21] Hayashi K, Uenoyama K, Mashima T, Sugioka Y. Remodelling of bone around hydroxyapatite and titanium in experimental osteoporosis. Biomaterials 1994;15:11-6.
-
(1994)
Biomaterials
, vol.15
, pp. 11-16
-
-
Hayashi, K.1
Uenoyama, K.2
Mashima, T.3
Sugioka, Y.4
-
22
-
-
0027381478
-
Hydorxyapatite ceramic coating for bone implant fixation. Mechnical and histrological studies ub dogs
-
[22] Søballe K. Hydorxyapatite ceramic coating for bone implant fixation. Mechnical and histrological studies ub dogs. Acta Orthop Scand 1993;64(Suppl 255):1-64.
-
(1993)
Acta Orthop Scand
, vol.64
, Issue.SUPPL. 255
, pp. 1-64
-
-
Søballe, K.1
-
23
-
-
0027610623
-
Mechanical and histological evaluation of amorphous calcium phopshate and poorly crystallized hydroxyapatite coatings on titanium implants
-
[23] Maxian SH, Zawadsky JP, Dunn MG. Mechanical and histological evaluation of amorphous calcium phopshate and poorly crystallized hydroxyapatite coatings on titanium implants. J Biomed Mater Res 1993;27:717-28.
-
(1993)
J Biomed Mater Res
, vol.27
, pp. 717-728
-
-
Maxian, S.H.1
Zawadsky, J.P.2
Dunn, M.G.3
|