-
1
-
-
0027295283
-
A fiber optic biosensor: Combination tapered fibers designed for improved signal acquisition
-
Anderson G.P., Golden J.P., Ligler F.S. A fiber optic biosensor: combination tapered fibers designed for improved signal acquisition. Biosensors and Bioelectronics. 8:1993;249-256.
-
(1993)
Biosensors and Bioelectronics
, vol.8
, pp. 249-256
-
-
Anderson, G.P.1
Golden, J.P.2
Ligler, F.S.3
-
2
-
-
0344354329
-
Flight of the biosensor
-
NRL/PU/5230-97-320
-
Anderson, G.P., Ligler, F.S., Stenger, D.A., Davidson, P.T., Foch, R.J., MacKrell, J.F., 1997. Flight of the biosensor. NRL Review, NRL/PU/5230-97-320, pp. 55-60.
-
(1997)
NRL Review
, pp. 55-60
-
-
Anderson, G.P.1
Ligler, F.S.2
Stenger, D.A.3
Davidson, P.T.4
Foch, R.J.5
MacKrell, J.F.6
-
3
-
-
0032435358
-
Quantifying serum anti-plague antibody using a fiber optic biosensor
-
Submitted to
-
Anderson, G.P., King, K.D., Cao, L.K., Jacoby, M.A., Ligler, F.S., Ezzell, J., 1998. Quantifying serum anti-plague antibody using a fiber optic biosensor. Submitted to CDLI.
-
(1998)
CDLI
-
-
Anderson, G.P.1
King, K.D.2
Cao, L.K.3
Jacoby, M.A.4
Ligler, F.S.5
Ezzell, J.6
-
4
-
-
0024596397
-
Use of thiol-terminal silanes and heterobifunctional cross-linkers for immobilization of antibodies on silica surfaces
-
Bhatia S.K., Shriver-Lake L.C., Prior K.J., Georger J.H., Calvert J.M., Bredehorst R., Ligler F.S. Use of thiol-terminal silanes and heterobifunctional cross-linkers for immobilization of antibodies on silica surfaces. Anal. Biochem. 178:1989;408-413.
-
(1989)
Anal. Biochem.
, vol.178
, pp. 408-413
-
-
Bhatia, S.K.1
Shriver-Lake, L.C.2
Prior, K.J.3
Georger, J.H.4
Calvert, J.M.5
Bredehorst, R.6
Ligler, F.S.7
-
5
-
-
0028796386
-
Detection of Yersinia pestis Fraction 1-antigen with a fiber optic biosensor
-
Cao L.K., Anderson G.P., Ligler F.S., Ezzell J. Detection of Yersinia pestis Fraction 1-antigen with a fiber optic biosensor. J. Clin. Microbiol. 33:1994;336-341.
-
(1994)
J. Clin. Microbiol.
, vol.33
, pp. 336-341
-
-
Cao, L.K.1
Anderson, G.P.2
Ligler, F.S.3
Ezzell, J.4
-
6
-
-
0001739487
-
Portable multichannel fiber optic biosensor for field detection
-
Golden J.P., Saaski E.W., Shriver-Lake L.C., Anderson G.P., Ligler F.S. Portable multichannel fiber optic biosensor for field detection. Optical Eng. 36:1997;1008-1013.
-
(1997)
Optical Eng.
, vol.36
, pp. 1008-1013
-
-
Golden, J.P.1
Saaski, E.W.2
Shriver-Lake, L.C.3
Anderson, G.P.4
Ligler, F.S.5
-
7
-
-
0032529730
-
Remote sensing using an airborne biosensor
-
Ligler F.S., Anderson G.P., Davidson P.T., Foch R.J., Ives J.T., King K.D., Page G., Stenger D.A., Whelan J.P. Remote sensing using an airborne biosensor. Environ. Sci. Technol. 32:1998;2461-2466.
-
(1998)
Environ. Sci. Technol.
, vol.32
, pp. 2461-2466
-
-
Ligler, F.S.1
Anderson, G.P.2
Davidson, P.T.3
Foch, R.J.4
Ives, J.T.5
King, K.D.6
Page, G.7
Stenger, D.A.8
Whelan, J.P.9
-
9
-
-
0026803262
-
Detection of Clostridium botulinum Toxin A using a fiber optic-based biosensor
-
Ogert R.A., Brown J.E., Singh B.R., Shriver-Lake L.C., Ligler F.S. Detection of Clostridium botulinum Toxin A using a fiber optic-based biosensor. Anal. Biochem. 205:1992;306-312.
-
(1992)
Anal. Biochem.
, vol.205
, pp. 306-312
-
-
Ogert, R.A.1
Brown, J.E.2
Singh, B.R.3
Shriver-Lake, L.C.4
Ligler, F.S.5
-
10
-
-
0029346186
-
Detection of TNT in water using an evanescent wave fiber optic biosensor
-
Shriver-Lake L.C., Breslin K.A., Charles P.T., Conrad D.W., Golden J.P., Ligler F.S. Detection of TNT in water using an evanescent wave fiber optic biosensor. Anal. Chem. 34:1995;2431-2435.
-
(1995)
Anal. Chem.
, vol.34
, pp. 2431-2435
-
-
Shriver-Lake, L.C.1
Breslin, K.A.2
Charles, P.T.3
Conrad, D.W.4
Golden, J.P.5
Ligler, F.S.6
-
11
-
-
0031149101
-
Efficient immobilization of proteins by modification of plate surface with polystyrene derivatives
-
Suzuki N., Quesenberry M.S., Wang J.K., Lee R.T., Kobayashi K., Lee Y.C. Efficient immobilization of proteins by modification of plate surface with polystyrene derivatives. Anal. Biochem. 247:1997;412-416.
-
(1997)
Anal. Biochem.
, vol.247
, pp. 412-416
-
-
Suzuki, N.1
Quesenberry, M.S.2
Wang, J.K.3
Lee, R.T.4
Kobayashi, K.5
Lee, Y.C.6
-
12
-
-
0030051517
-
Quantitating staphylococcal enterotoxin B in diverse media using a portable fiber-optic biosensor
-
Tempelman L.A., King K.D., Anderson G.P., Ligler F.S. Quantitating staphylococcal enterotoxin B in diverse media using a portable fiber-optic biosensor. Anal. Biochem. 233:1996;50-57.
-
(1996)
Anal. Biochem.
, vol.233
, pp. 50-57
-
-
Tempelman, L.A.1
King, K.D.2
Anderson, G.P.3
Ligler, F.S.4
-
13
-
-
0001401601
-
The immobilization of immunoreactants on solid phases
-
Elsevier Science, Amsterdam, Chap. 13
-
Tijssen, P., 1985. The immobilization of immunoreactants on solid phases. In Practice and theory of enzyme immunoassays. Elsevier Science, Amsterdam, Chap. 13, pp. 297-315.
-
(1985)
In Practice and Theory of Enzyme Immunoassays
, pp. 297-315
-
-
Tijssen, P.1
|