-
1
-
-
0029346186
-
Detection of TNT in water using an evanescent wave fiber optic biosensor
-
L. C. Shriver-Lake, K. A. Breslin, P. T. Charles, D. W. Conrad, J. P. Golden, and F. S. Ligler, "Detection of TNT in water using an evanescent wave fiber optic biosensor," Anal. Chem. 67, 2431-2435 (1995).
-
(1995)
Anal. Chem.
, vol.67
, pp. 2431-2435
-
-
Shriver-Lake, L.C.1
Breslin, K.A.2
Charles, P.T.3
Conrad, D.W.4
Golden, J.P.5
Ligler, F.S.6
-
2
-
-
0030051517
-
Quantitating staphylococcal enterotoxin B in diverse media using a portable fiber-optic biosensor
-
L. A. Tempelman, K. D. King, G. P. Anderson, and F. S. Ligler, "Quantitating staphylococcal enterotoxin B in diverse media using a portable fiber-optic biosensor," Anal. Chem. 233, 50-57 (1996).
-
(1996)
Anal. Chem.
, vol.233
, pp. 50-57
-
-
Tempelman, L.A.1
King, K.D.2
Anderson, G.P.3
Ligler, F.S.4
-
3
-
-
0000147865
-
Use of cyanine dyes with evanescent wave fiber optic biosensors
-
L. A. Tempelman, J. P. Golden, G. P. Anderson, and F. S. Ligler, "Use of cyanine dyes with evanescent wave fiber optic biosensors," Proc. SPIE 2293, 139-148 (1994).
-
(1994)
Proc. SPIE
, vol.2293
, pp. 139-148
-
-
Tempelman, L.A.1
Golden, J.P.2
Anderson, G.P.3
Ligler, F.S.4
-
4
-
-
0027572577
-
Cyanine dye labeling reagents: Sulfoindocyanine succinimidyl esters
-
R. B. Mujumdar, L. A. Ernst, S. R. Mujumdar, C. J. Lewis, and A. S. Waggoner, "Cyanine dye labeling reagents: sulfoindocyanine succinimidyl esters," Bioconjugate Chem. 4(2), 105-111 (1993).
-
(1993)
Bioconjugate Chem.
, vol.4
, Issue.2
, pp. 105-111
-
-
Mujumdar, R.B.1
Ernst, L.A.2
Mujumdar, S.R.3
Lewis, C.J.4
Waggoner, A.S.5
-
5
-
-
0008839235
-
Fluorescent labels
-
D. Wise and L. Wingard, Eds., Humana Press, Clifton, NJ
-
R. P. Haugland, "Fluorescent labels," in Biosensors with Fiber Optics, D. Wise and L. Wingard, Eds., pp. 85-110, Humana Press, Clifton, NJ (1991).
-
(1991)
Biosensors with Fiber Optics
, pp. 85-110
-
-
Haugland, R.P.1
-
7
-
-
0024054717
-
Launching light into fiber cores from sources in the cladding
-
D. Marcuse, "Launching light into fiber cores from sources in the cladding," J. Lightwave Technol. 6(8), 1273-1279 (1988).
-
(1988)
J. Lightwave Technol.
, vol.6
, Issue.8
, pp. 1273-1279
-
-
Marcuse, D.1
-
8
-
-
0001367915
-
Fiber-optic biosensor for the detection of hazardous materials
-
F. S. Ligler, J. P. Golden, L. C. Shriver-Lake, R. A. Ogert, D. Wijesuriya, and G. P. Anderson, "Fiber-optic biosensor for the detection of hazardous materials," Immunomethods 3, 122-127 (1993).
-
(1993)
Immunomethods
, vol.3
, pp. 122-127
-
-
Ligler, F.S.1
Golden, J.P.2
Shriver-Lake, L.C.3
Ogert, R.A.4
Wijesuriya, D.5
Anderson, G.P.6
-
9
-
-
0028449990
-
Development of an evanescent wave fiber optic biosensor
-
G. P. Anderson, J. P. Golden, L. K. Cao, D. Wijesuria, L. C. Shriver-Lake and F. S. Ligler, "Development of an evanescent wave fiber optic biosensor," IEEE Eng. Med. Biol. 13, 358-363 (1994).
-
(1994)
IEEE Eng. Med. Biol.
, vol.13
, pp. 358-363
-
-
Anderson, G.P.1
Golden, J.P.2
Cao, L.K.3
Wijesuria, D.4
Shriver-Lake, L.C.5
Ligler, F.S.6
-
10
-
-
0000303598
-
Fluorometer and tapered fiber optic probes for sensing in the evanescent wave
-
J. P. Golden, L. C. Shriver-Lake, G. P. Anderson, R. B. Thompson, and F. S. Ligler, "Fluorometer and tapered fiber optic probes for sensing in the evanescent wave," Opt. Eng. 31(7), 1458-1462 (1992).
-
(1992)
Opt. Eng.
, vol.31
, Issue.7
, pp. 1458-1462
-
-
Golden, J.P.1
Shriver-Lake, L.C.2
Anderson, G.P.3
Thompson, R.B.4
Ligler, F.S.5
-
11
-
-
0027295283
-
A fiber optic biosensor: Combination tapered fibers designed for improved signal acquisition
-
G. P. Anderson, J. P. Golden, and F. S. Ligler, "A fiber optic biosensor: combination tapered fibers designed for improved signal acquisition," Biosens. Bioelectron. 8, 249-256 (1993).
-
(1993)
Biosens. Bioelectron.
, vol.8
, pp. 249-256
-
-
Anderson, G.P.1
Golden, J.P.2
Ligler, F.S.3
-
12
-
-
0024596397
-
Use of thiol-terminal silanes and heterobifunctional crosslinkers for immobilization of antibodies on silica surfaces
-
S. K. Bhatia, L. C. Shriver-Lake, K. J. Prior, J. H. Georger, J. M. Calvert, R. Bredehorst, and F. S. Ligler, "Use of thiol-terminal silanes and heterobifunctional crosslinkers for immobilization of antibodies on silica surfaces," Anal. Biochem. 178, 408-413 (1989).
-
(1989)
Anal. Biochem.
, vol.178
, pp. 408-413
-
-
Bhatia, S.K.1
Shriver-Lake, L.C.2
Prior, K.J.3
Georger, J.H.4
Calvert, J.M.5
Bredehorst, R.6
Ligler, F.S.7
-
13
-
-
0029212103
-
Multimode evanescent wave-based sensors: Enhancement strategies
-
E. Saaski, M. Bizak, and J. Yeatts, "Multimode evanescent wave-based sensors: enhancement strategies," Proc. SPIE 2574, 56-63 (1995).
-
(1995)
Proc. SPIE
, vol.2574
, pp. 56-63
-
-
Saaski, E.1
Bizak, M.2
Yeatts, J.3
|