메뉴 건너뛰기




Volumn 51, Issue 3, 1999, Pages 205-209

Comparison of a multi-leaf collimator with conformal blocks for the delivery of stereotactically guided conformal radiotherapy

Author keywords

Conformal; Multi leaf collimator; Stereotactic radiotherapy

Indexed keywords

ANALYTIC METHOD; ARTICLE; COLLIMATOR; GEOMETRY; HISTOGRAM; HUMAN; PRIORITY JOURNAL; STEREOTAXIC SURGERY; TREATMENT PLANNING; TUMOR VOLUME;

EID: 0033054565     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(99)00062-6     Document Type: Article
Times cited : (30)

References (15)
  • 1
    • 0031951585 scopus 로고    scopus 로고
    • A digital method for computing target margins in radiotherapy
    • Bedford JL, Shentall GS. A digital method for computing target margins in radiotherapy. Med. Phys. 1998;25:224-231.
    • (1998) Med. Phys. , vol.25 , pp. 224-231
    • Bedford, J.L.1    Shentall, G.S.2
  • 2
    • 0028009079 scopus 로고
    • Static field conformal stereotactic radiosurgery: Physical techniques
    • Bourland JD, McCollough KP. Static field conformal stereotactic radiosurgery: physical techniques. Int. J. Radiat. Oncol. Biol. Phys. 1994;28:471-479.
    • (1994) Int. J. Radiat. Oncol. Biol. Phys. , vol.28 , pp. 471-479
    • Bourland, J.D.1    McCollough, K.P.2
  • 4
    • 0032006261 scopus 로고    scopus 로고
    • A comparison of multileaf-collimator and alloy-block field shaping
    • Galvin JM, Han K, Cohen R. A comparison of multileaf-collimator and alloy-block field shaping. Int. J. Radiat. Oncol. Biol. Phys. 1998;40(3):721-731.
    • (1998) Int. J. Radiat. Oncol. Biol. Phys. , vol.40 , Issue.3 , pp. 721-731
    • Galvin, J.M.1    Han, K.2    Cohen, R.3
  • 6
    • 0025907619 scopus 로고
    • A non-invasive, relocatable stereotactic frame for fractionated radiotherapy and multiple imaging
    • Graham JD, Warrington AP, Gill SS, Brada M. A non-invasive, relocatable stereotactic frame for fractionated radiotherapy and multiple imaging. Radiother. Oncol. 1991;21:60-62.
    • (1991) Radiother. Oncol. , vol.21 , pp. 60-62
    • Graham, J.D.1    Warrington, A.P.2    Gill, S.S.3    Brada, M.4
  • 7
    • 0028788683 scopus 로고
    • Multileaf collimation versus conventional shielding blocks: A time and motion study of beam shaping in radiotherapy
    • Helyer SJ, Heisig S. Multileaf collimation versus conventional shielding blocks: a time and motion study of beam shaping in radiotherapy. Radiother. Oncol. 1995;37:61-64.
    • (1995) Radiother. Oncol. , vol.37 , pp. 61-64
    • Helyer, S.J.1    Heisig, S.2
  • 8
    • 0030777192 scopus 로고    scopus 로고
    • A comparison of arc-based and mini-multileaf collimator-based radiosurgery treatment plans
    • Kubo HD, Pappas CTE, Wilder RB. A comparison of arc-based and mini-multileaf collimator-based radiosurgery treatment plans. Radiother. Oncol. 1997;45:89-93.
    • (1997) Radiother. Oncol. , vol.45 , pp. 89-93
    • Kubo, H.D.1    Pappas, C.T.E.2    Wilder, R.B.3
  • 9
    • 0027495078 scopus 로고
    • Stereotactic radiotherapy of irregular targets: A comparison between static conformal beams and non-coplanar arcs
    • Laing RW, Bentley RE, Nahum AE, Warrington AP, Brada M. Stereotactic radiotherapy of irregular targets: a comparison between static conformal beams and non-coplanar arcs. Radiother. Oncol. 1993;28:241-246.
    • (1993) Radiother. Oncol. , vol.28 , pp. 241-246
    • Laing, R.W.1    Bentley, R.E.2    Nahum, A.E.3    Warrington, A.P.4    Brada, M.5
  • 10
    • 0029065603 scopus 로고
    • Multileaf collimation versus alloy blocks: Analysis of geometric accuracy
    • LoSasso T, Kutcher G. Multileaf collimation versus alloy blocks: analysis of geometric accuracy. Int. J. Radiat. Oncol. Biol. Phys. 1995;32:499-506.
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.32 , pp. 499-506
    • LoSasso, T.1    Kutcher, G.2
  • 11
    • 0028884182 scopus 로고
    • Conformal radiation therapy with fixed shaped coplanar or noncoplanar radiation beam bouquets: A possible alternative to radiosurgery
    • Marks LB, Sherouse GW, Das S, Bentel GC, Spencer DP, Turner D. Conformal radiation therapy with fixed shaped coplanar or noncoplanar radiation beam bouquets: a possible alternative to radiosurgery. Int. J. Radiat. Oncol. Biol. Phys. 1995;33:1209-1219.
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.33 , pp. 1209-1219
    • Marks, L.B.1    Sherouse, G.W.2    Das, S.3    Bentel, G.C.4    Spencer, D.P.5    Turner, D.6
  • 12
    • 0015948362 scopus 로고
    • The storage and manipulation of radiation dose data in a small digital computer
    • Milan J, Bentley RE. The storage and manipulation of radiation dose data in a small digital computer. Br. J. Radiol. 1974;47:115-121.
    • (1974) Br. J. Radiol. , vol.47 , pp. 115-121
    • Milan, J.1    Bentley, R.E.2
  • 13
    • 0028323191 scopus 로고
    • Different collimators in convergent beam irradiation of irregularly shaped intracranial target volumes
    • Otto-Oelschläger S, Schlegel W, Lorenz W. Different collimators in convergent beam irradiation of irregularly shaped intracranial target volumes. Radiother. Oncol. 1994;30:175-179.
    • (1994) Radiother. Oncol. , vol.30 , pp. 175-179
    • Otto-Oelschläger, S.1    Schlegel, W.2    Lorenz, W.3
  • 15
    • 0030906531 scopus 로고    scopus 로고
    • Comparison of miniature multileaf collimation (MMLC) with circular collimation for stereotactic treatment
    • Shiu A, Kooy H, Ewton J, et al. Comparison of miniature multileaf collimation (MMLC) with circular collimation for stereotactic treatment. Int. J. Radiat. Oncol. Biol. Phys. 1997;37:679-688.
    • (1997) Int. J. Radiat. Oncol. Biol. Phys. , vol.37 , pp. 679-688
    • Shiu, A.1    Kooy, H.2    Ewton, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.