메뉴 건너뛰기




Volumn 25, Issue 2, 1998, Pages 224-231

A digital method for computing target margins in radiotherapy

Author keywords

Margin; Outline; Planning target volume; Radiotherapy; Treatment planning

Indexed keywords

ANISOTROPY; HIGH ENERGY PHYSICS; RADIOTHERAPY;

EID: 0031951585     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598184     Document Type: Article
Times cited : (27)

References (17)
  • 4
    • 0028938971 scopus 로고
    • Accuracy of field alignment in radiotherapy of head and neck-cancer utilizing individualized face mask immobilization-a retrospective analysis of clinical-practice
    • C. F. Hess, R. D. Kortmann, R. Jany, A. Hamberger, and M. Bamberg, "Accuracy of field alignment in radiotherapy of head and neck-cancer utilizing individualized face mask immobilization-a retrospective analysis of clinical-practice," Radiother. Oncol. 34, 69-72 (1995).
    • (1995) Radiother. Oncol. , vol.34 , pp. 69-72
    • Hess, C.F.1    Kortmann, R.D.2    Jany, R.3    Hamberger, A.4    Bamberg, M.5
  • 5
    • 0029810297 scopus 로고    scopus 로고
    • Target margins for random geometrical treatment uncertainties in conformal radiotherapy
    • A. Bel, M. van Herk, and J. V. Lebesque, "Target margins for random geometrical treatment uncertainties in conformal radiotherapy," Med. Phys. 23, 1537-1545 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1537-1545
    • Bel, A.1    Van Herk, M.2    Lebesque, J.V.3
  • 7
    • 0030973792 scopus 로고    scopus 로고
    • Automatic calculation of three-dimensional margins around treatment volumes in radiotherapy planning
    • J. C. Stroom and P. R. M. Storchi, "Automatic calculation of three-dimensional margins around treatment volumes in radiotherapy planning," Phys. Med Biol. 42, 745-755 (1997).
    • (1997) Phys. Med Biol. , vol.42 , pp. 745-755
    • Stroom, J.C.1    Storchi, P.R.M.2
  • 10
    • 0029128897 scopus 로고
    • An estimate of the margin required when defining blocks around the prostate
    • D. Jones, M. D. Hafermann, J. W. Rieke, and S. S. Vermeulen, "An estimate of the margin required when defining blocks around the prostate," Br. J. Radiol. 68, 740-746 (1995).
    • (1995) Br. J. Radiol. , vol.68 , pp. 740-746
    • Jones, D.1    Hafermann, M.D.2    Rieke, J.W.3    Vermeulen, S.S.4
  • 11
    • 0028803534 scopus 로고
    • Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration
    • M. van Herk, A. Bruce, A. P. Guus Kroes, T. Shouman, A. Touw, and J. V. Lebesque, "Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration," Int. J. Radiat. Oncol., Biol., Phys. 33, 1311-1320 (1995).
    • (1995) Int. J. Radiat. Oncol., Biol., Phys. , vol.33 , pp. 1311-1320
    • Van Herk, M.1    Bruce, A.2    Guus Kroes, A.P.3    Shouman, T.4    Touw, A.5    Lebesque, J.V.6
  • 12
    • 0029912299 scopus 로고    scopus 로고
    • Accuracy of pelvic radiotherapy: Prospective analysis of 90 patients in a randomised trial of blocked versus standard radiotherapy
    • R. A. Huddart, A Nahum, A. Neal, M McLean, D. P Dearnaley, M. Law, J. Dyer, and D. Tait, "Accuracy of pelvic radiotherapy: prospective analysis of 90 patients in a randomised trial of blocked versus standard radiotherapy," Radiother. Oncol. 39, 19-29 (1996).
    • (1996) Radiother. Oncol. , vol.39 , pp. 19-29
    • Huddart, R.A.1    Nahum, A.2    Neal, A.3    McLean, M.4    Dearnaley, D.P.5    Law, M.6    Dyer, J.7    Tait, D.8
  • 13
    • 0028363588 scopus 로고
    • A randomized trial of patient repositioning during radiotherapy using a megavoltage imaging-system
    • J. Gildersleve, D. P. Dearnaley, P. M. Evans, M. Law, C. Rawlings, and W Swindell, "A randomized trial of patient repositioning during radiotherapy using a megavoltage imaging-system," Radiother. Oncol. 31, 161-168 (1994).
    • (1994) Radiother. Oncol. , vol.31 , pp. 161-168
    • Gildersleve, J.1    Dearnaley, D.P.2    Evans, P.M.3    Law, M.4    Rawlings, C.5    Swindell, W.6
  • 14
    • 0029791232 scopus 로고    scopus 로고
    • Implications of 3-dimensional target shape and motion in aperture design
    • E. Fontenla, C. A. Pelizzari, and G. T. Y. Chen, "Implications of 3-dimensional target shape and motion in aperture design," Med. Phys. 23, 1431-1441 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1431-1441
    • Fontenla, E.1    Pelizzari, C.A.2    Chen, G.T.Y.3
  • 17
    • 0028027605 scopus 로고
    • Influence of the positioning error on 3D conformal dose distributions during fractionated radiotherapy
    • V Rudat, M. Flentje, D. Oetzel, M. Menke, W. Schlegel, and M. Wannenmacher, "Influence of the positioning error on 3D conformal dose distributions during fractionated radiotherapy," Radiother. Oncol. 33, 56-63 (1994).
    • (1994) Radiother. Oncol. , vol.33 , pp. 56-63
    • Rudat, V.1    Flentje, M.2    Oetzel, D.3    Menke, M.4    Schlegel, W.5    Wannenmacher, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.