메뉴 건너뛰기




Volumn 47, Issue 3, 1999, Pages 298-303

Intravascular ultrasound-guided balloon angioplasty for treatment of in-stent restenosis

Author keywords

In stent restenosis; Intravascular ultrasound; Percutaneous transluminal coronary angioplasty

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTERY DIAMETER; ARTICLE; BALLOON CATHETER; CLINICAL ARTICLE; CORONARY STENT; FEMALE; FOLLOW UP; HUMAN; INTRAVASCULAR ULTRASOUND; MALE; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; RESTENOSIS; SAFETY; SECOND LOOK SURGERY; TREATMENT OUTCOME;

EID: 0033051727     PISSN: 15221946     EISSN: None     Source Type: Journal    
DOI: 10.1002/(sici)1522-726x(199907)47:3<298::aid-ccd9>3.0.co;2-8     Document Type: Article
Times cited : (12)

References (29)
  • 3
    • 0030070652 scopus 로고    scopus 로고
    • A randomized comparison of combined ticlopidine and aspirin therapy versus aspirin therapy alone after successful intravuscular ultrasound-guided stent implantation
    • Hall P, Nakamura S, Maiello L, Itoh A, Blengino S, Martini G, Ferraro M, Colombo A. A randomized comparison of combined ticlopidine and aspirin therapy versus aspirin therapy alone after successful intravuscular ultrasound-guided stent implantation. Circulation 1996;93:215-222.
    • (1996) Circulation , vol.93 , pp. 215-222
    • Hall, P.1    Nakamura, S.2    Maiello, L.3    Itoh, A.4    Blengino, S.5    Martini, G.6    Ferraro, M.7    Colombo, A.8
  • 5
    • 0028643558 scopus 로고
    • Four-year experience with Palmaz-Schatz stenting in coronary angioplasty complicated by dissection with threatened or present vessel closure
    • Schomig A, Kastrati A, Mudra H, Blasini R, Schuhlen H, Klauss V, Richardt G, Neumann FJ. Four-year experience with Palmaz-Schatz stenting in coronary angioplasty complicated by dissection with threatened or present vessel closure. Circulation 1994;90: 2716-2724.
    • (1994) Circulation , vol.90 , pp. 2716-2724
    • Schomig, A.1    Kastrati, A.2    Mudra, H.3    Blasini, R.4    Schuhlen, H.5    Klauss, V.6    Richardt, G.7    Neumann, F.J.8
  • 7
    • 0027931803 scopus 로고
    • Localized arterial wall drug delivery from a polymer-coated removable metallic stent: Kinetic, distribution, and bioactivity of forskolin
    • Lambert TL, Dev V, Rechavia E, Forrester JS, Litvack F, Eigler NL. Localized arterial wall drug delivery from a polymer-coated removable metallic stent: kinetic, distribution, and bioactivity of forskolin. Circulation 1994;90:1003-1011.
    • (1994) Circulation , vol.90 , pp. 1003-1011
    • Lambert, T.L.1    Dev, V.2    Rechavia, E.3    Forrester, J.S.4    Litvack, F.5    Eigler, N.L.6
  • 10
    • 0027508929 scopus 로고
    • Management of restenosis within the Palmaz-Schatz coronary stent: The U.S. multicenter experience
    • Baim DS, Levine MJ, Leon MB, Levine S, Ellis SG, Schatz RA, for the U.S. Palmaz-Schatz stent investigators. Management of restenosis within the Palmaz-Schatz coronary stent: the U.S. multicenter experience. Am J Cardiol 1993;71:364-366.
    • (1993) Am J Cardiol , vol.71 , pp. 364-366
    • Baim, D.S.1    Levine, M.J.2    Leon, M.B.3    Levine, S.4    Ellis, S.G.5    Schatz, R.A.6
  • 11
    • 0027534711 scopus 로고
    • Mechanisms of restenosis and redilation within coronary stents-quantitative angiographic assessment
    • Gordon PC, Gibson CM, Cohen DJ, Carrozza JP, Kuntz RE, Baim DS. Mechanisms of restenosis and redilation within coronary stents-quantitative angiographic assessment. J Am Coll Cardiol 1993;21:1166-1174.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 1166-1174
    • Gordon, P.C.1    Gibson, C.M.2    Cohen, D.J.3    Carrozza, J.P.4    Kuntz, R.E.5    Baim, D.S.6
  • 12
    • 0030091602 scopus 로고    scopus 로고
    • Remediesfor in-stent restenosis
    • Satler LF. Remediesfor in-stent restenosis. Cathet Cadiovasc Diagn 1996;37:320-321.
    • (1996) Cathet Cadiovasc Diagn , vol.37 , pp. 320-321
    • Satler, L.F.1
  • 13
    • 0030339681 scopus 로고    scopus 로고
    • Rotational atherectomy for treatment of in-stent restenosis: Role of intracoronary ultrasound guidance
    • Stone GW. Rotational atherectomy for treatment of in-stent restenosis: role of intracoronary ultrasound guidance. Cathet Cadiovasc Diagn 1996;37(suppl 3):73-77.
    • (1996) Cathet Cadiovasc Diagn , vol.37 , Issue.3 SUPPL. , pp. 73-77
    • Stone, G.W.1
  • 16
    • 0030823247 scopus 로고    scopus 로고
    • Treatment of in-stent restenosis with excimer laser coronary angioplasty: Mechanisms and results compared with PTCA alone
    • Mehran R, Mintz GS, Satler LF, Pichard AD, Kent KM, Bucher TA, Popma JJ, Leon MB. Treatment of in-stent restenosis with excimer laser coronary angioplasty: mechanisms and results compared with PTCA alone. Circulation 1997;96:2183-2189.
    • (1997) Circulation , vol.96 , pp. 2183-2189
    • Mehran, R.1    Mintz, G.S.2    Satler, L.F.3    Pichard, A.D.4    Kent, K.M.5    Bucher, T.A.6    Popma, J.J.7    Leon, M.B.8
  • 22
    • 0030297772 scopus 로고    scopus 로고
    • Chronic arterial responses to stent implantation: A serial intravascular ultrasound anarysis of Palmaz-Schatz stents in native coronary arteries
    • Hoffmann R, Mintz GS, Popma JJ, Satler LF, Pichard AD, Kent KM, Walsh C, Mackell P, Leon MB. Chronic arterial responses to stent implantation: a serial intravascular ultrasound anarysis of Palmaz-Schatz stents in native coronary arteries. J Am Coll Cardiol 1996;28:1134-1139.
    • (1996) J Am Coll Cardiol , vol.28 , pp. 1134-1139
    • Hoffmann, R.1    Mintz, G.S.2    Popma, J.J.3    Satler, L.F.4    Pichard, A.D.5    Kent, K.M.6    Walsh, C.7    Mackell, P.8    Leon, M.B.9
  • 24
    • 0030811110 scopus 로고    scopus 로고
    • Comparison of coronary luminal quantification obtained from intracoronary ultrasound and both geometric quantitative angiography before and after balloon angioplasty and directional atherectomy
    • Ozaki Y, Violaris AG, Kobayashi T, Keane D, Camenzind E, Di Mario C, de Feyter P, Roelandt JRTC, Serruys PW. Comparison of coronary luminal quantification obtained from intracoronary ultrasound and both geometric quantitative angiography before and after balloon angioplasty and directional atherectomy. Circulation 1997;96:491-499.
    • (1997) Circulation , vol.96 , pp. 491-499
    • Ozaki, Y.1    Violaris, A.G.2    Kobayashi, T.3    Keane, D.4    Camenzind, E.5    Di Mario, C.6    De Feyter, P.7    Roelandt, J.R.T.C.8    Serruys, P.W.9
  • 25
    • 0030999078 scopus 로고    scopus 로고
    • Improved procedural result of coronary angioplasty with intravascular ultrasound-guided balloon sizing: The CLOUT pilot trial
    • Stone GW, Hodgson JM, St Goar FG, Frey A, Mudra H, Sheehan H, Linnemeier TJ, for the Clinical Outcomes With Ultrasound Trial (CLOUT) Investigators. Improved procedural result of coronary angioplasty with intravascular ultrasound-guided balloon sizing: the CLOUT pilot trial. Circulation 1997;95:2044-2052.
    • (1997) Circulation , vol.95 , pp. 2044-2052
    • Stone, G.W.1    Hodgson, J.M.2    St Goar, F.G.3    Frey, A.4    Mudra, H.5    Sheehan, H.6    Linnemeier, T.J.7
  • 28
    • 0032477679 scopus 로고    scopus 로고
    • Six-month angiographic outcome after successful repeat percutaneous intervention for in-stent restenosis
    • Bauters C, Banos JL, van Belle E, Mc Fadden EP, Lablanche JM, Bertrand ME. Six-month angiographic outcome after successful repeat percutaneous intervention for in-stent restenosis. Circulation 1998;97:318-312.
    • (1998) Circulation , vol.97 , pp. 318-1312
    • Bauters, C.1    Banos, J.L.2    Van Belle, E.3    Mc Fadden, E.P.4    Lablanche, J.M.5    Bertrand, M.E.6
  • 29
    • 0002072304 scopus 로고    scopus 로고
    • Long-term clinical and quantitative angiographic follow-up after the Palmaz-Schatz stent restenosis
    • Yokoi H, Kimura T, Nakagawa Y, Nosaka H, Nobuyoshi M. Long-term clinical and quantitative angiographic follow-up after the Palmaz-Schatz stent restenosis. Am J Cardiol 1996;27:224A.
    • (1996) Am J Cardiol , vol.27
    • Yokoi, H.1    Kimura, T.2    Nakagawa, Y.3    Nosaka, H.4    Nobuyoshi, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.