메뉴 건너뛰기




Volumn 280, Issue 1-2, 1999, Pages 135-145

Commutability and traceability: Their repercussions on analytical bias and inaccuracy

Author keywords

Biological variation; Commutability; Traceability

Indexed keywords

ACCURACY; CALIBRATOR; CONFERENCE PAPER; HUMAN; HUMAN TISSUE; LABORATORY; LABORATORY TEST; PRIORITY JOURNAL; QUALITY CONTROL; RELIABILITY; STANDARD;

EID: 0033003880     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0009-8981(98)00187-9     Document Type: Conference Paper
Times cited : (12)

References (19)
  • 1
    • 0019466135 scopus 로고
    • Matrix effects in clinical analysis: Commutability of control materials between the Ektachem, Beckman and SMA 12/60 glucose and urea methods
    • Clark P., Kricka L.J., Whitehead T.P. Matrix effects in clinical analysis: commutability of control materials between the Ektachem, Beckman and SMA 12/60 glucose and urea methods. Clin Chim Acta. 113:1981;293-303.
    • (1981) Clin Chim Acta , vol.113 , pp. 293-303
    • Clark, P.1    Kricka, L.J.2    Whitehead, T.P.3
  • 2
    • 0027375825 scopus 로고
    • Commutability of reference materials in clinical chemistry
    • Franzini C. Commutability of reference materials in clinical chemistry. JIFCC. 5:1993;186-193.
    • (1993) JIFCC , vol.5 , pp. 186-193
    • Franzini, C.1
  • 3
    • 0004021751 scopus 로고
    • International vocabulary of basic and general terms in metrology
    • BIPM, IFC, IIFCC, ISO, TUPAC, LUPAP, OIML Switzerland
    • BIPM, IFC, IIFCC, ISO, TUPAC, LUPAP, OIML. International vocabulary of basic and general terms in metrology. ISO 2nd ed. Switzerland, 1993.
    • (1993) ISO 2nd Ed.
  • 4
    • 0029621069 scopus 로고
    • Commutability between stabilized materials and human serum in serum creatinine testing
    • Ricós C., Juvany R., Álvarez V.et al. Commutability between stabilized materials and human serum in serum creatinine testing. Quim Clin. 14:1995;350-356.
    • (1995) Quim Clin , vol.14 , pp. 350-356
    • Ricós, C.1    Juvany, R.2    Álvarez, V.3
  • 5
    • 0029610913 scopus 로고
    • Commutability between stabilized materials and human serum cholesterol, glucose, urate and urea testing
    • Minchinela J., Perich C., Juvany R.et al. Commutability between stabilized materials and human serum cholesterol, glucose, urate and urea testing. Quim Clin. 14:1995;357-363.
    • (1995) Quim Clin , vol.14 , pp. 357-363
    • Minchinela, J.1    Perich, C.2    Juvany, R.3
  • 6
    • 0030787372 scopus 로고    scopus 로고
    • Commutability between stabilized materials and fresh human serum to improve laboratory performance
    • Ricós C., Juvany R., Álvarez V.et al. Commutability between stabilized materials and fresh human serum to improve laboratory performance. Clin Chim Acta. 263:1997;225-238.
    • (1997) Clin Chim Acta , vol.263 , pp. 225-238
    • Ricós, C.1    Juvany, R.2    Álvarez, V.3
  • 7
    • 0031564315 scopus 로고    scopus 로고
    • Procedure for studying commutability validated by biological variation
    • Ricós C., Juvany R., Jiménez C.V.et al. Procedure for studying commutability validated by biological variation. Clin Chim Acta. 268:1998;73-83.
    • (1998) Clin Chim Acta , vol.268 , pp. 73-83
    • Ricós, C.1    Juvany, R.2    Jiménez, C.V.3
  • 8
    • 0021045350 scopus 로고
    • A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, part 1
    • Passing H., Bablok W. A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, part 1. J Clin Chem Clin Biochem. 21:1983;709-720.
    • (1983) J Clin Chem Clin Biochem , vol.21 , pp. 709-720
    • Passing, H.1    Bablok, W.2
  • 9
    • 84942072472 scopus 로고
    • Comparison of several regression procedures for method comparison studies and determination of sample sizes. Application of linear regression procedures for method comparison studies in clinical chemistry, part 2
    • Passing H., Bablok W. Comparison of several regression procedures for method comparison studies and determination of sample sizes. Application of linear regression procedures for method comparison studies in clinical chemistry, part 2. J Clin Chem Clin Biochem. 22:1984;431-445.
    • (1984) J Clin Chem Clin Biochem , vol.22 , pp. 431-445
    • Passing, H.1    Bablok, W.2
  • 10
    • 0030042948 scopus 로고    scopus 로고
    • External quality assessment: Currently used criteria for evaluating performance in European countries, and criteria for future harmonization
    • Ricós C., Baadenhuijsen H., Libeer J.C.et al. External quality assessment: currently used criteria for evaluating performance in European countries, and criteria for future harmonization. Eur J Clin Chem Clin Biochem. 34:1996;159-165.
    • (1996) Eur J Clin Chem Clin Biochem , vol.34 , pp. 159-165
    • Ricós, C.1    Baadenhuijsen, H.2    Libeer, J.C.3
  • 11
    • 0024238335 scopus 로고
    • Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical area
    • Gowans E.M.S., Hyltoft Petersen P., Blaabjerg O., Horder M. Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical area. Scan J Clin Lab Invest. 47:1988;757-764.
    • (1988) Scan J Clin Lab Invest , vol.47 , pp. 757-764
    • Gowans, E.M.S.1    Hyltoft Petersen, P.2    Blaabjerg, O.3    Horder, M.4
  • 13
    • 0030989954 scopus 로고    scopus 로고
    • Intermethod variability of sodium and potassium results: Patients sera and commercially available control sera
    • Catozzo G., Fabi A., Franzini C. Intermethod variability of sodium and potassium results: patients sera and commercially available control sera. Eur J Clin Chem Clin Biochem. 35:1997;387-392.
    • (1997) Eur J Clin Chem Clin Biochem , vol.35 , pp. 387-392
    • Catozzo, G.1    Fabi, A.2    Franzini, C.3
  • 14
    • 0003739219 scopus 로고
    • External quality assessment in clinical laboratories
    • Doctoral thesis. Antwerp
    • Libeer JC. External quality assessment in clinical laboratories. European perspectives; today and tomorrow. Doctoral thesis. Antwerp, 1993.
    • (1993) European Perspectives; Today and Tomorrow
    • Libeer, J.C.1
  • 15
    • 0344893603 scopus 로고    scopus 로고
    • Química seca versus química convencional
    • Doctoral Thesis. Barcelona: Universitat Autònoma de Barcelona, Departament de Bioquimica i Biologia Molecular
    • Juvany R. Química seca versus química convencional. Impacto de la conmutabilidad sobre la transferibilidad de los resultados. Doctoral Thesis. Barcelona: Universitat Autònoma de Barcelona, Departament de Bioquimica i Biologia Molecular, 1996.
    • (1996) Impacto de la Conmutabilidad Sobre la Transferibilidad de Los Resultados
    • Juvany, R.1
  • 16
    • 84944428084 scopus 로고
    • Analytical quality specifications for reference methods and operating specifications for networks of reference laboratories
    • Thienpont L., Franzini C., Kratochvila J.et al. Analytical quality specifications for reference methods and operating specifications for networks of reference laboratories. Eur J Clin Chem Clin Biochem. 33:1995;949-957.
    • (1995) Eur J Clin Chem Clin Biochem , vol.33 , pp. 949-957
    • Thienpont, L.1    Franzini, C.2    Kratochvila, J.3
  • 17
    • 0027516650 scopus 로고
    • Achieving accuracy for routine clinical chemistry methods by using patient specimen correlations to assign calibrator values
    • Lasky F.D. Achieving accuracy for routine clinical chemistry methods by using patient specimen correlations to assign calibrator values. Arch Pathol Lab Med. 117:1993;412-419.
    • (1993) Arch Pathol Lab Med , vol.117 , pp. 412-419
    • Lasky, F.D.1
  • 18
    • 0026784427 scopus 로고
    • Proficiency testing linked to the National References System for the clinical laboratory. A proposal for achieving accuracy
    • Lasky F.D. Proficiency testing linked to the National References System for the clinical laboratory. A proposal for achieving accuracy. Clin Chem. 38:1992;1260-1267.
    • (1992) Clin Chem , vol.38 , pp. 1260-1267
    • Lasky, F.D.1
  • 19
    • 0029813456 scopus 로고    scopus 로고
    • Characterization and classification of EQA according to objectives such as evaluation of method and participant bias and standard deviation
    • Libeer J.C., Baadenhuijsen H., Fraser C.G.et al. Characterization and classification of EQA according to objectives such as evaluation of method and participant bias and standard deviation. Eur J Clin Chem Clin Biochem. 34:1996;665-678.
    • (1996) Eur J Clin Chem Clin Biochem , vol.34 , pp. 665-678
    • Libeer, J.C.1    Baadenhuijsen, H.2    Fraser, C.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.