메뉴 건너뛰기




Volumn 34, Issue 8, 1996, Pages 665-678

Characterization and classification of external quality assessment schemes (EQA) according to objectives such as evaluation of method and participant bias and standard deviation discussion paper from the members of the external quality assessment (EQA) working group a1 on analytical goals in laboratory medicine

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; LABORATORY; PRIORITY JOURNAL; QUALITY CONTROL; TOTAL QUALITY MANAGEMENT;

EID: 0029813456     PISSN: 09394974     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (59)

References (49)
  • 1
    • 84957355141 scopus 로고
    • Survey of the accuracy of clinical analysis in clinical laboratories
    • Belk WP, Sunderman FW. Survey of the accuracy of clinical analysis in clinical laboratories. Am J Clin Pathol 1947; 17:853-61.
    • (1947) Am J Clin Pathol , vol.17 , pp. 853-861
    • Belk, W.P.1    Sunderman, F.W.2
  • 2
    • 33749175560 scopus 로고    scopus 로고
    • ISO/REMCON231, 1991.
    • ISO/REMCON231, 1991.
  • 3
    • 84895404514 scopus 로고
    • The international harmonized protocol for the proficiency testing of (chemical) analytical laboratories
    • ISO/IUPAC/AOAC. The international harmonized protocol for the proficiency testing of (chemical) analytical laboratories. Pure Appl Chem 1993; 65:3-20.
    • (1993) Pure Appl Chem , vol.65 , pp. 3-20
  • 4
    • 0003739219 scopus 로고
    • External quality assessment in clinical laboratories
    • PhD thesis, University of Antwerp
    • Libeer JC. External quality assessment in clinical laboratories. European perspectives: today and tomorrow. PhD thesis, University of Antwerp, 1993.
    • (1993) European Perspectives: Today and Tomorrow
    • Libeer, J.C.1
  • 5
    • 0003063414 scopus 로고
    • Adding new scopes to traditional EQA schemes emphasizing quality improvement
    • Hyltoft Petersen P, Blaabjerb O, Irjala K, editors. Assessing quality in measurements of plasma proteins. Nordkem Clinical Chemistry Project, Helsiniki, Finland
    • Olafsdottir E, Hellsing K, Steensland H, Terhunen R, Uldall A. Adding new scopes to traditional EQA schemes emphasizing quality improvement. In: Hyltoft Petersen P, Blaabjerb O, Irjala K, editors. Assessing quality in measurements of plasma proteins. The Nordic Protein Project and Related Projects. Nordkem Clinical Chemistry Project, Helsiniki, Finland, 1994:187-94.
    • (1994) Nordic Protein Project and Related Projects , pp. 187-194
    • Olafsdottir, E.1    Hellsing, K.2    Steensland, H.3    Terhunen, R.4    Uldall, A.5
  • 6
    • 33749171974 scopus 로고
    • Elements of analytical quality
    • Hyltoft Petersen P, Blaabjerg O, Irjala K, editors. Assessing quality in measurements of plasma proteins. Nordkem Clinical Chemistry Project, Helsinki, Finland
    • Hyltoft Petersen P, Blaabjerg O, Irjala K, Icen A, Bj0tro K. Elements of analytical quality. In: Hyltoft Petersen P, Blaabjerg O, Irjala K, editors. Assessing quality in measurements of plasma proteins. The Nordic Protein Project and Related Projects. Nordkem Clinical Chemistry Project, Helsinki, Finland, 1994:19-39.
    • (1994) Nordic Protein Project and Related Projects , pp. 19-39
    • Hyltoft Petersen, P.1    Blaabjerg, O.2    Irjala, K.3    Icen, A.4
  • 7
    • 0028924977 scopus 로고
    • Result, error and uncertainty
    • Dybkaer R. Result, error and uncertainty. Scand J Clin Lab Invest 1995; 55:97-118.
    • (1995) Scand J Clin Lab Invest , vol.55 , pp. 97-118
    • Dybkaer, R.1
  • 9
    • 0028487051 scopus 로고
    • The combined target approach - A way out of the proficiency testing dilemma [letter]
    • Stöckl D, Thienpont LM. The combined target approach - a way out of the proficiency testing dilemma [letter]. Arch Pathol Lab Med 1994; 118:775.
    • (1994) Arch Pathol Lab Med , vol.118 , pp. 775
    • Stöckl, D.1    Thienpont, L.M.2
  • 10
    • 0028078070 scopus 로고
    • Accuracy in clinical chemistry - Does anybody care? [opinion]
    • Tietz NW, Accuracy in clinical chemistry - does anybody care? [opinion]. Clin Chem 1994; 40:859-61.
    • (1994) Clin Chem , vol.40 , pp. 859-861
    • Tietz, N.W.1
  • 12
    • 0027413476 scopus 로고
    • College of American Pathologists Conference XXIII. Matrix effects and accuracy assessment in clinical chemistry
    • Miller WG, Kaufman HW, McLendon WW, editors. College of American Pathologists Conference XXIII. Matrix effects and accuracy assessment in clinical chemistry. Arch Pathol Lab Med 1993; 117:343-436.
    • (1993) Arch Pathol Lab Med , vol.117 , pp. 343-436
    • Miller, W.G.1    Kaufman, H.W.2    McLendon, W.W.3
  • 13
    • 84944428084 scopus 로고
    • Analytical quality specifications for reference methods and operating specifications for networks of reference laboratories. Recommendations of the European EQA-Organizers Working Group B
    • Thienpont LM, Franzini C, Kratochvila J, Middle J, Ricos C, Siekmann L, Stöckl D. Analytical quality specifications for reference methods and operating specifications for networks of reference laboratories. Recommendations of the European EQA-Organizers Working Group B. Eur J Clin Chem Clin Biochem 1995; 33:949-57.
    • (1995) Eur J Clin Chem Clin Biochem , vol.33 , pp. 949-957
    • Thienpont, L.M.1    Franzini, C.2    Kratochvila, J.3    Middle, J.4    Ricos, C.5    Siekmann, L.6    Stöckl, D.7
  • 14
    • 0028045594 scopus 로고
    • Enzyme reference materials
    • Moss DW. Enzyme reference materials. JIFCC 1994; 6(1):6-9.
    • (1994) JIFCC , vol.6 , Issue.1 , pp. 6-9
    • Moss, D.W.1
  • 15
    • 0022898380 scopus 로고
    • Reference materials for clinical enzymology: The work of the Community Bureau of Reference from the European Community
    • Moss DW, Schiele F, Siest G, Colinet E. Reference materials for clinical enzymology: The work of the Community Bureau of Reference from the European Community. Clin Chem 1986; 32:556-8.
    • (1986) Clin Chem , vol.32 , pp. 556-558
    • Moss, D.W.1    Schiele, F.2    Siest, G.3    Colinet, E.4
  • 16
    • 0023873090 scopus 로고
    • The place of reference materials in clinical enzymology
    • Moss DW. The place of reference materials in clinical enzymology. Clin Chim Acta 1988; 173:1-8.
    • (1988) Clin Chim Acta , vol.173 , pp. 1-8
    • Moss, D.W.1
  • 17
    • 0028102111 scopus 로고
    • Factors influencing between-laboratory variability of C-reactive protein results as evidenced by the Belgian External Quality Assessment (EQA) Scheme
    • Devleeschouwer N, Libeer JC, Chapelle JP, Struvay CL, Gyssels C, L'Hoir A, Albert A. Factors influencing between-laboratory variability of C-reactive protein results as evidenced by the Belgian External Quality Assessment (EQA) Scheme. Scand J Clin Lab Invest 1994; 54:435-40.
    • (1994) Scand J Clin Lab Invest , vol.54 , pp. 435-440
    • Devleeschouwer, N.1    Libeer, J.C.2    Chapelle, J.P.3    Struvay, C.L.4    Gyssels, C.5    L'Hoir, A.6    Albert, A.7
  • 19
    • 0023894884 scopus 로고
    • Evolution of evaluation criteria in the CAP surveys
    • Ross JW. Evolution of evaluation criteria in the CAP surveys. Arch Pathol Lab Med 1988; 112:334-9.
    • (1988) Arch Pathol Lab Med , vol.112 , pp. 334-339
    • Ross, J.W.1
  • 20
    • 0023987870 scopus 로고
    • Proficiency testing programspromises, progress, and problems: A 40-year prospective
    • Laessig RH, Ehrmeyer SS. Proficiency testing programspromises, progress, and problems: a 40-year prospective. Arch Pathol Lab Med 1988; 112:329-33.
    • (1988) Arch Pathol Lab Med , vol.112 , pp. 329-333
    • Laessig, R.H.1    Ehrmeyer, S.S.2
  • 21
    • 33749170419 scopus 로고
    • Report of a WHO Group. 1979 Dec 4-7; Brussels
    • External quality assessment of health laboratories. Report of a WHO Group. 1979 Dec 4-7; Brussels. Regional office for Europe. Copenhagen, 1981.
    • (1981) Regional Office for Europe. Copenhagen
  • 23
    • 0027128154 scopus 로고
    • Medicare, Medicaid and CLIA Programs: Regulations implementing the clinical laboratory improvement admendments of 1988 (CLIA)
    • US Department of Health and Human Services. Medicare, Medicaid and CLIA Programs: regulations implementing the clinical laboratory improvement admendments of 1988 (CLIA), Final Rule, Fed Regist 1992; 57:7002-186.
    • (1992) Final Rule, Fed Regist , vol.57 , pp. 7002-7186
  • 24
    • 0003179886 scopus 로고
    • Bichtlinien der Bundesärztekammer zur Qualitätssicherung in medizinischen Laboratorien
    • Anonymous. Bichtlinien der Bundesärztekammer zur Qualitätssicherung in medizinischen Laboratorien. Dtsch Ärztebl 1988; 85:A699-A712.
    • (1988) Dtsch Ärztebl , vol.85
  • 25
    • 84990291854 scopus 로고
    • A new concept for quality control of clinical laboratory investigations in the light of clinical requirements and based on reference method values
    • Stamm DA. A new concept for quality control of clinical laboratory investigations in the light of clinical requirements and based on reference method values. J Clin Chem Clin Biochem 1982; 20:817-22.
    • (1982) J Clin Chem Clin Biochem , vol.20 , pp. 817-822
    • Stamm, D.A.1
  • 26
    • 4244044592 scopus 로고
    • Übergangsregelungen für die "Richtlinien der Bundesärztekammer zur Qualitätssicherung in medizinischen Laboratorien"
    • Anonymous. Übergangsregelungen für die "Richtlinien der Bundesärztekammer zur Qualitätssicherung in medizinischen Laboratorien". Dtsch Ärztebl 1994; 91 :B176-7.
    • (1994) Dtsch Ärztebl , vol.91
  • 27
    • 0027346833 scopus 로고
    • A study of interferences in routine methods for creatinine measurements
    • Kenny D. A study of interferences in routine methods for creatinine measurements. Scand J Clin Lab Invest 1993; 53 (212 Suppl):43-7.
    • (1993) Scand J Clin Lab Invest , vol.53 , Issue.212 SUPPL. , pp. 43-47
    • Kenny, D.1
  • 28
    • 0025893319 scopus 로고
    • Interferences in current methods for measurements of creatinine
    • Weber JA, van Zanten AP. Interferences in current methods for measurements of creatinine. Clin Chem 1991; 37:695-700
    • (1991) Clin Chem , vol.37 , pp. 695-700
    • Weber, J.A.1    Van Zanten, A.P.2
  • 30
    • 33749176918 scopus 로고
    • Acceptability of EQA results using different performance criteria
    • Libeer JC, Albert A. Acceptability of EQA results using different performance criteria. Ann Biol Clin 1993; 51:395.
    • (1993) Ann Biol Clin , vol.51 , pp. 395
    • Libeer, J.C.1    Albert, A.2
  • 31
    • 0023909611 scopus 로고
    • Survey of special practices associated with College of American Pathologists proficiency testing in the Commonwealth of Pennsylvania
    • Cembrowski GS, Vanderlinde RE. Survey of special practices associated with College of American Pathologists proficiency testing in the Commonwealth of Pennsylvania. Arch Pathol Lab Med 1988; 112:374-7.
    • (1988) Arch Pathol Lab Med , vol.112 , pp. 374-377
    • Cembrowski, G.S.1    Vanderlinde, R.E.2
  • 32
    • 33749170096 scopus 로고
    • Report EUR.EN: EQAS for health care related analysis. Organization and functioning of external quality assessment schemes (EQAS)
    • European Commission DGXII, Measurement and Testing Programme, Report EUR.EN: EQAS for health care related analysis. Organization and functioning of external quality assessment schemes (EQAS) in E. C. member States together with Finland, Sweden, Switzerland and Norway. Edited by C. Dirscherl C. 1993.
    • (1993) E. C. Member States Together with Finland, Sweden, Switzerland and Norway. Edited by C. Dirscherl C.
  • 33
    • 44949270001 scopus 로고
    • External quality assessment in clinical chemistry. Review of the European situation with particular reference to hormonology
    • Colinet E. External quality assessment in clinical chemistry. Review of the European situation with particular reference to hormonology. Nucl Med Biol Int J Radiât Appl Instrum Part B 1990; 17:681-5.
    • (1990) Nucl Med Biol Int J Radiât Appl Instrum Part B , vol.17 , pp. 681-685
    • Colinet, E.1
  • 34
    • 0029437613 scopus 로고
    • External quality assurance in Belgium
    • Libeer JC. External quality assurance in Belgium. Ann 1st Super Sanità 1995; 31:43-51.
    • (1995) Ann 1st Super Sanità , vol.31 , pp. 43-51
    • Libeer, J.C.1
  • 35
    • 0041198229 scopus 로고
    • The Belgian external quality assessment schemes in microbiology and parasitology
    • Libeer JC, Simonet L, Hamers N. The Belgian external quality assessment schemes in microbiology and parasitology. Med Microbiol Lett 1994; 3:209-16.
    • (1994) Med Microbiol Lett , vol.3 , pp. 209-216
    • Libeer, J.C.1    Simonet, L.2    Hamers, N.3
  • 36
    • 0001068517 scopus 로고
    • Validation de Techniques" de la SFBC., Protocole de validation de techniques (document B, annexe 5)
    • Vassault A, Grafmeyer D, Naudin C, Dumont G, Bailly M, Henny J, et al. "Validation de Techniques" de la SFBC., Protocole de validation de techniques (document B, annexe 5). Ann Biol Clin 1986; 44:686-745.
    • (1986) Ann Biol Clin , vol.44 , pp. 686-745
    • Vassault, A.1    Grafmeyer, D.2    Naudin, C.3    Dumont, G.4    Bailly, M.5    Henny, J.6
  • 37
    • 0025944978 scopus 로고
    • Combi scheme: New combined internal/external quality-assessment scheme in the Netherlands
    • Steigstra H, Jansen RTP, Baadenhuijsen H. Combi scheme: new combined internal/external quality-assessment scheme in the Netherlands. Clin Chem 1991; 37:1196-204.
    • (1991) Clin Chem , vol.37 , pp. 1196-1204
    • Steigstra, H.1    Jansen, R.T.P.2    Baadenhuijsen, H.3
  • 39
    • 0028519798 scopus 로고
    • Setting quality standards in clinical chemistry: Can competing models based on analytical, biological and clinical outcomes be harmonized? [editorial]
    • Hyltoft Petersen P, Fraser CG. Setting quality standards in clinical chemistry: can competing models based on analytical, biological and clinical outcomes be harmonized? [editorial]. Clin Chem 1994; 40:1865-8.
    • (1994) Clin Chem , vol.40 , pp. 1865-1868
    • Hyltoft Petersen, P.1    Fraser, C.G.2
  • 40
    • 0028384472 scopus 로고
    • Proficiency testing, matrix effects, and method evaluation [editorial]
    • Rej R. Proficiency testing, matrix effects, and method evaluation [editorial]. Clin Chem 1994; 40:345-6.
    • (1994) Clin Chem , vol.40 , pp. 345-346
    • Rej, R.1
  • 42
    • 0029670425 scopus 로고    scopus 로고
    • Accuracy-based assessment of proficiency testing results using serum from single donations: Possibilities and limitations
    • Stöckl D, Libeer JC, Reinauer H, Thienpont LM, De Leenheer AP. Accuracy-based assessment of proficiency testing results using serum from single donations: possibilities and limitations. Clin Chem 1996; 42:469-70.
    • (1996) Clin Chem , vol.42 , pp. 469-470
    • Stöckl, D.1    Libeer, J.C.2    Reinauer, H.3    Thienpont, L.M.4    De Leenheer, A.P.5
  • 44
    • 0026559707 scopus 로고
    • A collaborative trial for the evaluation of blood cholesterol measurements in clinical laboratories in Italy
    • Malavasi B, Catapano A, Galli G, Granzini C. A collaborative trial for the evaluation of blood cholesterol measurements in clinical laboratories in Italy. Eur J Clin Chem Clin Biochem 1992; 30:157-61.
    • (1992) Eur J Clin Chem Clin Biochem , vol.30 , pp. 157-161
    • Malavasi, B.1    Catapano, A.2    Galli, G.3    Granzini, C.4
  • 46
    • 0023728740 scopus 로고
    • A report from the laboratory standardisation panel of the National Cholesterol Education Program
    • Current status of blood cholesterol measurements in clinical laboratories in the United States: a report from the laboratory standardisation panel of the National Cholesterol Education Program. Clin Chem 1988; 34:193-201.
    • (1988) Clin Chem , vol.34 , pp. 193-201
  • 48
    • 33749188215 scopus 로고
    • Laboratory quality improvement in Ontario, Canada: The role of distance education through audio teleconferencing
    • Crawford L, Forint M, Richardson H. Laboratory quality improvement in Ontario, Canada: the role of distance education through audio teleconferencing. EQAnews 1995; 6(4):46-9.
    • (1995) EQAnews , vol.6 , Issue.4 , pp. 46-49
    • Crawford, L.1    Forint, M.2    Richardson, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.