메뉴 건너뛰기




Volumn 28, Issue 5, 1999, Pages 451-457

Loads on internal spinal fixation devices summary;Die belastung des wirbel-fixateur-interne

Author keywords

Anterior interbody fusion; Brace; Internal spinal fixation device; Loads; Telemetry

Indexed keywords

ANTERIOR SPINE FUSION; ARTICLE; BIOMECHANICS; OSTEOSYNTHESIS; SPINE STABILIZATION; STANDING; SURGICAL INSTRUMENT; THORACIC SPINE; WALKING;

EID: 0032997683     PISSN: 00854530     EISSN: None     Source Type: Journal    
DOI: 10.1007/PL00003629     Document Type: Article
Times cited : (14)

References (16)
  • 1
    • 0026729555 scopus 로고
    • An improved method of stature measurement for quantitative determination of spinal loading
    • Althoff I, Brinckmann P, Frobin W, Sandover J, Burton K (1992) An improved method of stature measurement for quantitative determination of spinal loading. Spine 17: 682-693
    • (1992) Spine , vol.17 , pp. 682-693
    • Althoff, I.1    Brinckmann, P.2    Frobin, W.3    Sandover, J.4    Burton, K.5
  • 2
    • 0032994310 scopus 로고    scopus 로고
    • Estimation of trunk muscle forces using the finite element method and in vivo loads measured by telemeterized internal spinal fixation devices
    • Calisse J, Rohlmann A, Bergmann G (1999) Estimation of trunk muscle forces using the finite element method and in vivo loads measured by telemeterized internal spinal fixation devices. J Biomechanics 32: 727-731
    • (1999) J Biomechanics , vol.32 , pp. 727-731
    • Calisse, J.1    Rohlmann, A.2    Bergmann, G.3
  • 4
    • 0030043486 scopus 로고    scopus 로고
    • Patient monitoring system for load measurement with spinal fixation devices
    • Graichen F, Bergmann G, Rohlmann A (1996) Patient monitoring system for load measurement with spinal fixation devices. Med Eng Phys 18: 167-174
    • (1996) Med Eng Phys , vol.18 , pp. 167-174
    • Graichen, F.1    Bergmann, G.2    Rohlmann, A.3
  • 5
    • 0026463901 scopus 로고
    • The indications and principles of correction of posttraumatic deformities
    • Harms J, Stoltze D (1992) The indications and principles of correction of posttraumatic deformities. Eur Spine J 1: 142-151
    • (1992) Eur Spine J , vol.1 , pp. 142-151
    • Harms, J.1    Stoltze, D.2
  • 6
    • 0013888190 scopus 로고
    • The load on lumbar discs in different positions of the body
    • Nachemson A (1966) The load on lumbar discs in different positions of the body. Clin Orthop 45: 107-122
    • (1966) Clin Orthop , vol.45 , pp. 107-122
    • Nachemson, A.1
  • 7
    • 0028472612 scopus 로고
    • A spinal fixation device for in vivo load measurement
    • Rohlmann A, Bergmann G, Graichen F (1994) A spinal fixation device for in vivo load measurement. J Biomech 27: 961-967
    • (1994) J Biomech , vol.27 , pp. 961-967
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3
  • 8
    • 0031060065 scopus 로고    scopus 로고
    • Loads on an internal spinal fixation device during walking
    • Rohlmann A, Bergmann G, Graichen F (1997) Loads on an internal spinal fixation device during walking. J Biomech 30: 41-47
    • (1997) J Biomech , vol.30 , pp. 41-47
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3
  • 9
    • 0029598737 scopus 로고
    • Telemeterized load measurement using instrumented spinal internal fixators in a patient with degenerative instability
    • Rohlmann A, Bergmann G, Graichen F, Mayer M-M (1995) Telemeterized load measurement using instrumented spinal internal fixators in a patient with degenerative instability. Spine 20: 2683-2689
    • (1995) Spine , vol.20 , pp. 2683-2689
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3    Mayer, M.-M.4
  • 10
    • 0032033635 scopus 로고    scopus 로고
    • Influence of muscle forces on loads in internal spinal fixation devices
    • Rohlmann A, Bergmann G, Graichen F, Mayer H-M (1998) Influence of muscle forces on loads in internal spinal fixation devices. Spine 23: 537-542
    • (1998) Spine , vol.23 , pp. 537-542
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3    Mayer, H.-M.4
  • 11
    • 0033083679 scopus 로고    scopus 로고
    • Braces do not not reduce loads on internal spinal fixation devices
    • Rohlmann A, Bergmann G, Graichen F, Neff G (1999) Braces do not not reduce loads on internal spinal fixation devices. Clin Biomech 14: 97-102
    • (1999) Clin Biomech , vol.14 , pp. 97-102
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3    Neff, G.4
  • 12
    • 0028892528 scopus 로고
    • In vivo measurement of implant loads in a patient with a fractured vertebral body
    • Rohlmann A, Bergmann G, Graichen F, Weber U (1995) In vivo measurement of implant loads in a patient with a fractured vertebral body. Eur Spine J 4: 347-353
    • (1995) Eur Spine J , vol.4 , pp. 347-353
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3    Weber, U.4
  • 13
    • 0028217257 scopus 로고
    • A universal spine tester for in vitro experiments with muscle force simulation
    • Wilke H-J, Claes L, Schmitt H, Wolf S (1994) A universal spine tester for in vitro experiments with muscle force simulation. Eur Spine J 3: 91-97
    • (1994) Eur Spine J , vol.3 , pp. 91-97
    • Wilke, H.-J.1    Claes, L.2    Schmitt, H.3    Wolf, S.4
  • 14
    • 53049100490 scopus 로고    scopus 로고
    • Neue intradiskale in vivo druckmessungen bei alltagsbelastungen
    • Wilke H-J, Claes LE (Hrsg). Springer, Berlin Heidelberg New York
    • Wilke H-J, Neef P, Caimi M, Hoogland Th, Claes L (1998) Neue intradiskale in vivo Druckmessungen bei Alltagsbelastungen. In: Wilke H-J, Claes LE (Hrsg) Die traumatische und degenerative Bandscheibe. Springer, Berlin Heidelberg New York
    • (1998) Die Traumatische und Degenerative Bandscheibe
    • Wilke, H.-J.1    Neef, P.2    Caimi, M.3    Hoogland, Th.4    Claes, L.5
  • 16
    • 0028036716 scopus 로고
    • A historical cohort study of pedicle screw fixation in thoracic, lumbar, and sacral spinal fusions
    • Yuan HA, Garfin SR, Dickman CA, Mardjetko SM (1994) A historical cohort study of pedicle screw fixation in thoracic, lumbar, and sacral spinal fusions. Spine 19: 2279-2296
    • (1994) Spine , vol.19 , pp. 2279-2296
    • Yuan, H.A.1    Garfin, S.R.2    Dickman, C.A.3    Mardjetko, S.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.