메뉴 건너뛰기




Volumn 14, Issue 2, 1999, Pages 97-102

Braces do not reduce loads on internal spinal fixation devices

Author keywords

Internal spinal fixator; Load measurement; Spinal orthoses; Spine; Telemetry

Indexed keywords

BRACES (FOR LIMBS AND JOINTS); IMPLANTS (SURGICAL); TELEMETERING;

EID: 0033083679     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0268-0033(98)00056-4     Document Type: Article
Times cited : (40)

References (15)
  • 3
    • 0001422703 scopus 로고
    • The immobilizing efficiency of back braces
    • Norton PL, Brown T. The immobilizing efficiency of back braces. J Bone Joint Surg [Am] 1957;39:111-138.
    • (1957) J Bone Joint Surg [Am] , vol.39 , pp. 111-138
    • Norton, P.L.1    Brown, T.2
  • 4
    • 0013611646 scopus 로고
    • Röntgenologische funktionsstudien an der lendenwirbelsäule bei fixierung durch gebräuchliche korsette
    • Maier K. Röntgenologische funktionsstudien an der lendenwirbelsäule bei fixierung durch gebräuchliche korsette. Z Orthop 1984;95: 319-330.
    • (1984) Z Orthop , vol.95 , pp. 319-330
    • Maier, K.1
  • 5
    • 75949155598 scopus 로고
    • In vivo measurement of intradiscal pressure
    • Nachemson A, Morris JM. In vivo measurement of intradiscal pressure. J Bone Joint Surg [Am] 1964;46:1077-1092.
    • (1964) J Bone Joint Surg [Am] , vol.46 , pp. 1077-1092
    • Nachemson, A.1    Morris, J.M.2
  • 6
    • 0031060065 scopus 로고    scopus 로고
    • Loads on an internal spinal fixation device during walking
    • Rohlmann A, Bergmann G, Graichen F. Loads on an internal spinal fixation device during walking. J Biomech 1997;30:41-47.
    • (1997) J Biomech , vol.30 , pp. 41-47
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3
  • 7
    • 0029598737 scopus 로고
    • Telemeterized load measurement using instrumented spinal internal fixators in a patient with degenerative instability
    • Rohlmann A, Bergmann G, Graichen F, Mayer H-M. Telemeterized load measurement using instrumented spinal internal fixators in a patient with degenerative instability. Spine 1995;20:2683-2689.
    • (1995) Spine , vol.20 , pp. 2683-2689
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3    Mayer, H.-M.4
  • 8
    • 0032033635 scopus 로고    scopus 로고
    • Influence of muscle forces on loads in internal spinal fixation devices
    • Rohlmann A, Bergmann G, Graichen F, Mayer H-M. Influence of muscle forces on loads in internal spinal fixation devices. Spine 1998;23:537-542.
    • (1998) Spine , vol.23 , pp. 537-542
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3    Mayer, H.-M.4
  • 9
    • 0028892528 scopus 로고
    • In vivo measurement of implant loads in a patient with a fractured vertebral body
    • Rohlmann A, Bergmann G, Graichen F, Weber U. In vivo measurement of implant loads in a patient with a fractured vertebral body. Eur Spine J 1995;4:347-353.
    • (1995) Eur Spine J , vol.4 , pp. 347-353
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3    Weber, U.4
  • 10
    • 0030043486 scopus 로고    scopus 로고
    • Patient monitoring system for load measurement with spinal fixation devices
    • Graichen F, Bergmann G, Rohlmann A. Patient monitoring system for load measurement with spinal fixation devices. Med Eng Phys 1996;18:167-174.
    • (1996) Med Eng Phys , vol.18 , pp. 167-174
    • Graichen, F.1    Bergmann, G.2    Rohlmann, A.3
  • 11
    • 0028472612 scopus 로고
    • A spinal fixation device for in vivo load measurement
    • Rohlmann A, Bergmann G, Graichen F. A spinal fixation device for in vivo load measurement. J Biomech 1994;27:961-967.
    • (1994) J Biomech , vol.27 , pp. 961-967
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3
  • 12
    • 0021144925 scopus 로고
    • Untersuchungen zum wirkungsprinzip der lumbotrainbandage
    • Yücel M, Breitenfelder J, Liebscher F, Nicol K. Untersuchungen zum wirkungsprinzip der lumbotrainbandage. Z Orthop 1984;122:287-289.
    • (1984) Z Orthop , vol.122 , pp. 287-289
    • Yücel, M.1    Breitenfelder, J.2    Liebscher, F.3    Nicol, K.4
  • 13
    • 0026720569 scopus 로고
    • Effect of lumbar orthosis on intervertebral mobility. A roentgen stereophotogrammetric analysis
    • Axelsson P, Johnsson R, Strömqvist B. Effect of lumbar orthosis on intervertebral mobility. A roentgen stereophotogrammetric analysis. Spine 1992;17:678-681.
    • (1992) Spine , vol.17 , pp. 678-681
    • Axelsson, P.1    Johnsson, R.2    Strömqvist, B.3
  • 14
    • 0029784029 scopus 로고    scopus 로고
    • Clamping stiffness and its influence on load distribution between paired internal spinal fixation devices
    • Rohlmann A, Calisse J, Bergmann G, Radvan J, Mayer H-M. Clamping stiffness and its influence on load distribution between paired internal spinal fixation devices. J Spinal Disord 1996;9:234-240.
    • (1996) J Spinal Disord , vol.9 , pp. 234-240
    • Rohlmann, A.1    Calisse, J.2    Bergmann, G.3    Radvan, J.4    Mayer, H.-M.5
  • 15
    • 0013633216 scopus 로고
    • Spinal orthoses
    • Bunch WH, Keagy R, Kritter AE, et al. editors. St Louis: CV Mosby
    • Fishman S, Berger N, Edelstein JE, Springer WP. Spinal orthoses. In: Bunch WH, Keagy R, Kritter AE, et al. editors. Atlas of Orthotics. St Louis: CV Mosby, 1985:238-256.
    • (1985) Atlas of Orthotics , pp. 238-256
    • Fishman, S.1    Berger, N.2    Edelstein, J.E.3    Springer, W.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.