메뉴 건너뛰기




Volumn 34, Issue 3, 1999, Pages 236-241

MRI dosimetry: A fast quantitative MRI method to determine 3D absorbed dose distributions

Author keywords

3D dose distributions; Fast T1 measurements; Flash sequences; Nuclear magnetic resonance dosimetry

Indexed keywords

ARTICLE; DOSIMETRY; IMAGE ANALYSIS; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUANTITATIVE DIAGNOSIS; RADIATION DOSE DISTRIBUTION; THREE DIMENSIONAL IMAGING;

EID: 0032974024     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004424-199903000-00014     Document Type: Article
Times cited : (4)

References (18)
  • 1
    • 0026765378 scopus 로고
    • Three dimensional dose mapping from gamma-knife treatment using a dosimeter gel and MR-imaging
    • Olsson L, Arndt J, Fransson A, Nordell B. Three dimensional dose mapping from gamma-knife treatment using a dosimeter gel and MR-imaging. Radiother Oncol 1992;24:82-86.
    • (1992) Radiother Oncol , vol.24 , pp. 82-86
    • Olsson, L.1    Arndt, J.2    Fransson, A.3    Nordell, B.4
  • 2
    • 0026003076 scopus 로고
    • Measurement of three dimensional radiation dose distributions using MRI
    • Prasad P, Nalcioglu O, Rabbabi B. Measurement of three dimensional radiation dose distributions using MRI. Radiat Reson 1991;128:1-13.
    • (1991) Radiat Reson , vol.128 , pp. 1-13
    • Prasad, P.1    Nalcioglu, O.2    Rabbabi, B.3
  • 4
    • 0027131528 scopus 로고
    • Assessment of the accuracy of stereotactic radiosurgery using Fricke-infused gels and MRI
    • Schultz RJ, Maryanski M, Ibbot G, Bond J. Assessment of the accuracy of stereotactic radiosurgery using Fricke-infused gels and MRI. Med Phys 1993;20:1731-1735.
    • (1993) Med Phys , vol.20 , pp. 1731-1735
    • Schultz, R.J.1    Maryanski, M.2    Ibbot, G.3    Bond, J.4
  • 5
    • 0021232591 scopus 로고
    • Measurement of radiation dose distribution by nuclear magnetic resonance (NMR) imaging
    • Gore JC, Kang YS, Schultz RJ. Measurement of radiation dose distribution by nuclear magnetic resonance (NMR) imaging. Phys Med Biol 1984;29:1189-1197.
    • (1984) Phys Med Biol , vol.29 , pp. 1189-1197
    • Gore, J.C.1    Kang, Y.S.2    Schultz, R.J.3
  • 6
    • 0000321527 scopus 로고
    • The chemical action of Roentgen rays on a dilute ferrous sulfate solution as a measure of a dose
    • Fricke H, Morse S. The chemical action of Roentgen rays on a dilute ferrous sulfate solution as a measure of a dose. Am J Roentgenol Radium Therapy Nucl Med 1927;18:430-432.
    • (1927) Am J Roentgenol Radium Therapy Nucl Med , vol.18 , pp. 430-432
    • Fricke, H.1    Morse, S.2
  • 7
    • 0024569814 scopus 로고
    • Ferrous sulfate gels for determination of absorbed dose distributions using MRI technique : Basic studies
    • Olsson LE, Petterson S, Ahlgren L, Mattsson S. Ferrous sulfate gels for determination of absorbed dose distributions using MRI technique : Basic studies. Phys Med Biol 1989;34:43-52.
    • (1989) Phys Med Biol , vol.34 , pp. 43-52
    • Olsson, L.E.1    Petterson, S.2    Ahlgren, L.3    Mattsson, S.4
  • 8
    • 0028864141 scopus 로고
    • Correcting for rf inhomogeneities in multiecho pulse sequence MRI dosimetry
    • Duzenli C and Robinson D. Correcting for rf inhomogeneities in multiecho pulse sequence MRI dosimetry. Med Phys 1995;22: 1645-1650.
    • (1995) Med Phys , vol.22 , pp. 1645-1650
    • Duzenli, C.1    Robinson, D.2
  • 9
    • 0027997190 scopus 로고
    • Dose distributions measurements in superficial x-rays beams using NMR dosimetry
    • Kron T and Pope JM. Dose Distributions measurements in superficial x-rays beams using NMR dosimetry. Phys Med Biol 1994;39: 1337-1349.
    • (1994) Phys Med Biol , vol.39 , pp. 1337-1349
    • Kron, T.1    Pope, J.M.2
  • 10
    • 0030637826 scopus 로고    scopus 로고
    • 1 imaging of dual gel samples for diffusion measurements in NMR dosimetry gels
    • 1 imaging of dual gel samples for diffusion measurements in NMR dosimetry gels. Magn Reson Imaging 1997:15(2):211-221.
    • (1997) Magn Reson Imaging , vol.15 , Issue.2 , pp. 211-221
    • Kron, T.1    Jonas, D.2    Pope, J.3
  • 13
    • 0029915548 scopus 로고    scopus 로고
    • Signal to noise ration comparison between surface coils and implanted coils
    • Arnder LL, Shattuck MD, Black RD. Signal to noise ration comparison between surface coils and implanted coils. Magn Reson Med 1996;35:727-733.
    • (1996) Magn Reson Med , vol.35 , pp. 727-733
    • Arnder, L.L.1    Shattuck, M.D.2    Black, R.D.3
  • 15
    • 0033043606 scopus 로고    scopus 로고
    • In vivo tissue extracellular volume fraction measurement by dynamic spinlattice MRI relaxometry: Application to the characterization of muscle fiber types
    • Dedieu V, Finat-Duclos F, Renou JP, Joffre F, Vincensini D. In vivo tissue extracellular volume fraction measurement by dynamic spinlattice MRI relaxometry: application to the characterization of muscle fiber types. Invest Radiol 1999;34(3):185-189.
    • (1999) Invest Radiol , vol.34 , Issue.3 , pp. 185-189
    • Dedieu, V.1    Finat-Duclos, F.2    Renou, J.P.3    Joffre, F.4    Vincensini, D.5
  • 16
    • 45949115591 scopus 로고
    • Transverse coherence in rapid flash NMR imaging
    • Frahm J, Hanicke W, Merboldt KD. Transverse coherence in rapid flash NMR imaging. J Magn Reson 1987;72:307-314.
    • (1987) J Magn Reson , vol.72 , pp. 307-314
    • Frahm, J.1    Hanicke, W.2    Merboldt, K.D.3
  • 17
    • 0030058455 scopus 로고    scopus 로고
    • Measurements of dynamic wedge angles and beam profiles by MRI ferrous sulfate gel dosimetry
    • Bengsson M, Furre T, Roedal J, Skretting A, Olsen D. Measurements of dynamic wedge angles and beam profiles by MRI ferrous sulfate gel dosimetry. Phys Med Biol 1996;41:269-277.
    • (1996) Phys Med Biol , vol.41 , pp. 269-277
    • Bengsson, M.1    Furre, T.2    Roedal, J.3    Skretting, A.4    Olsen, D.5
  • 18
    • 0029941612 scopus 로고    scopus 로고
    • An automated fast MR-imaging method for localized measurements of dose distributions using NMR-Fricke gel dosimetry. Evaluation of influences on the measurement accuracy
    • Reichl B, Matthaei D, Richter J, Haase A. An automated fast MR-imaging method for localized measurements of dose distributions using NMR-Fricke gel dosimetry. Evaluation of influences on the measurement accuracy. Strahlenther Onkol 1996; 172:312-319.
    • (1996) Strahlenther Onkol , vol.172 , pp. 312-319
    • Reichl, B.1    Matthaei, D.2    Richter, J.3    Haase, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.