메뉴 건너뛰기




Volumn 35, Issue 5, 1996, Pages 727-733

Signal-to-noise ratio comparison between surface coils and implanted coils

Author keywords

implanted coils; magnetic resonance microscopy; signal to noise (SNR); surface coils

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; MAGNETIC RESONANCE; MAGNETIC RESONANCE IMAGING; PREDICTIVE ANALYTICS;

EID: 0029915548     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910350514     Document Type: Article
Times cited : (28)

References (15)
  • 1
  • 3
    • 0028283069 scopus 로고
    • Studies on bromobenzene-induced hepatotoxicity using in vivo MR microscopy with surgically implanted rf coils
    • X. Zhou, R. R. Maronpot, G. P. Cofer, L. W. Hedlund, G. A. Johnson, Studies on bromobenzene-induced hepatotoxicity using in vivo MR microscopy with surgically implanted rf coils. Magn. Reson. Med. 31, 619-627 (1994).
    • (1994) Magn. Reson. Med. , vol.31 , pp. 619-627
    • Zhou, X.1    Maronpot, R.R.2    Cofer, G.P.3    Hedlund, L.W.4    Johnson, G.A.5
  • 6
    • 0025340863 scopus 로고
    • Maximizing contrast to noise with inductively coupled implanted coils
    • T. H. R. Farmer, G. P. Cofer, G. A. Johnson, Maximizing contrast to noise with inductively coupled implanted coils. Invest. Radiol. 25, 552-558 (1990).
    • (1990) Invest. Radiol. , vol.25 , pp. 552-558
    • Farmer, T.H.R.1    Cofer, G.P.2    Johnson, G.A.3
  • 7
    • 0028072726 scopus 로고
    • Magnetic resonance microscopy of the rat carotid artery at 300 megahertz
    • L. L. Arnder, X. Zhou, G. P. Cofer, L. W. Hedlund, G. A. Johnson, Magnetic resonance microscopy of the rat carotid artery at 300 megahertz. Invest. Radiol 29, 822-826 (1994).
    • (1994) Invest. Radiol , vol.29 , pp. 822-826
    • Arnder, L.L.1    Zhou, X.2    Cofer, G.P.3    Hedlund, L.W.4    Johnson, G.A.5
  • 8
    • 0023484759 scopus 로고
    • Sample noise with circular surface coils
    • M. D. Harpen, Sample noise with circular surface coils. Med. Phys. 14, 616-618 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 616-618
    • Harpen, M.D.1
  • 9
    • 0003328461 scopus 로고
    • The calculation of the magnetic field of rotating machines. Part 3. Eddy currents induced in a solid slab by a circular current loop
    • P. Hammond, The calculation of the magnetic field of rotating machines. Part 3. Eddy currents induced in a solid slab by a circular current loop, in "Proc., IEEE (monograph 514S) 109C," pp. 508-515, 1962.
    • (1962) Proc., IEEE (Monograph 514S) 109C , pp. 508-515
    • Hammond, P.1
  • 10
    • 9244235876 scopus 로고
    • Electricity and magnetism for NMR: A review of basic concepts
    • (S. R. Thomas, R. L. Dixon, Eds.), Medical Physics Monograph 14, American Association of Physics in Medicine (American Institute of Physics), New York
    • K. E. Ekstrand, R. L. Dixon, Electricity and magnetism for NMR: a review of basic concepts, in "NMR Medicine: The Instrumentation and Clinical Applications" (S. R. Thomas, R. L. Dixon, Eds.), Medical Physics Monograph 14, American Association of Physics in Medicine (American Institute of Physics), New York, 1986.
    • (1986) NMR Medicine: The Instrumentation and Clinical Applications
    • Ekstrand, K.E.1    Dixon, R.L.2
  • 11
    • 0000132799 scopus 로고
    • The sensitivity of the zeugmatographic experiment involving human samples
    • D. I. Hoult, P. C. Lauterbur, The sensitivity of the zeugmatographic experiment involving human samples. J. Magn. Reson. 34, 425-433 (1979).
    • (1979) J. Magn. Reson. , vol.34 , pp. 425-433
    • Hoult, D.I.1    Lauterbur, P.C.2
  • 12
    • 49549133678 scopus 로고
    • The signal-to-noise ratio of the nuclear magnetic resonance experiment
    • D. I. Hoult, R. E. Richards, The signal-to-noise ratio of the nuclear magnetic resonance experiment. J. Magn. Reson. 24, 71-85 (1976).
    • (1976) J. Magn. Reson. , vol.24 , pp. 71-85
    • Hoult, D.I.1    Richards, R.E.2
  • 14
    • 0021748537 scopus 로고
    • Estimating patient dielectric losses in NMR images
    • T. W. Redpath, J. M. S. Hutchinson, Estimating patient dielectric losses in NMR images. Magn. Reson. Imaging 2, 295-300 (1984).
    • (1984) Magn. Reson. Imaging , vol.2 , pp. 295-300
    • Redpath, T.W.1    Hutchinson, J.M.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.