Volumn 2, Issue 3, 1998, Pages 273-277

The Effect of Delivered Energy on Defibrillation Shock Impedance

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CARDIOVERSION; COMPARATIVE STUDY; DEFIBRILLATOR; FEMALE; HEART ARRHYTHMIA; HUMAN; IMPEDANCE; INSTRUMENTATION; MALE; MIDDLE AGED; PATHOPHYSIOLOGY; STANDARD; TREATMENT OUTCOME;

EID: 0032152434     PISSN: 1383875X     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1009745222443     Document Type: Article
Times cited : (6)

References (22)
  • 1
    • 0023736265 scopus 로고
    • Current-based versus energy-based ventricular defibrillation: A prospective study
    • Lerman BB, DiMarco JP, Haines DE. Current-based versus energy-based ventricular defibrillation: A prospective study. J Am Coll Cardiol 1988;12:1259-1264.
    • (1988) J Am Coll Cardiol , vol.12 , pp. 1259-1264
    • Lerman, B.B.1    DiMarco, J.P.2    Haines, D.E.3
  • 2
    • 0023938827 scopus 로고
    • Energy, current, and success in defibrillation and cardioversion: Clinical studies using an automated impedance-based method of energy adjustment
    • Kerber RE, Martins JB, Kienzle MG, et al. Energy, current, and success in defibrillation and cardioversion: Clinical studies using an automated impedance-based method of energy adjustment. Circulation 1988;77:1038-1046.
    • (1988) Circulation , vol.77 , pp. 1038-1046
    • Kerber, R.E.1    Martins, J.B.2    Kienzle, M.G.3
  • 3
    • 0019497010 scopus 로고
    • Transthoracic resistance in human defibrillation: Influence of body weight, chest size, serial shocks, paddle size and paddle contact pressure
    • Kerber RE, Grayzel J, Hoye R, et al. Transthoracic resistance in human defibrillation: Influence of body weight, chest size, serial shocks, paddle size and paddle contact pressure. Circulation 1981;63:676-682.
    • (1981) Circulation , vol.63 , pp. 676-682
    • Kerber, R.E.1    Grayzel, J.2    Hoye, R.3
  • 4
    • 0022380547 scopus 로고
    • The implanted defibrillator: Relation of a defibrillating lead configuration and clinical variables to defibrillation threshold
    • Troup PJ, Chapman PD, Olinger GN, et al. The implanted defibrillator: Relation of a defibrillating lead configuration and clinical variables to defibrillation threshold. J Am Coll Cardiol 1985;6:1315-1321.
    • (1985) J Am Coll Cardiol , vol.6 , pp. 1315-1321
    • Troup, P.J.1    Chapman, P.D.2    Olinger, G.N.3
  • 5
    • 0025878541 scopus 로고
    • Electrode system influence on biphasic waveform defibrillation efficacy in humans
    • Bardy GH, Troutman C, Johnson G, et al. Electrode system influence on biphasic waveform defibrillation efficacy in humans. Circulation 1991;84:665-671.
    • (1991) Circulation , vol.84 , pp. 665-671
    • Bardy, G.H.1    Troutman, C.2    Johnson, G.3
  • 6
    • 0029128807 scopus 로고
    • Optimal electrode configuration for pectoral transvenous implantable defibrillator without an active can
    • Swerdlow CD, Davie S, Kass RM, et al. Optimal electrode configuration for pectoral transvenous implantable defibrillator without an active can. Am J Cardiol 1995;76:370-374.
    • (1995) Am J Cardiol , vol.76 , pp. 370-374
    • Swerdlow, C.D.1    Davie, S.2    Kass, R.M.3
  • 7
    • 0030237562 scopus 로고    scopus 로고
    • The effect of an active pectoral pulse generator shell on defibrillation efficacy with a transvenous lead system
    • Gold MR, Foster AH, Shorofsky SR. The effect of an active pectoral pulse generator shell on defibrillation efficacy with a transvenous lead system. Am J Cardiol 1996;78:540-543.
    • (1996) Am J Cardiol , vol.78 , pp. 540-543
    • Gold, M.R.1    Foster, A.H.2    Shorofsky, S.R.3
  • 8
    • 0030221145 scopus 로고    scopus 로고
    • Chronic rise in defibrillation threshold with a hybrid lead system
    • Tummula RV, Riggio DR, Peters RW, et al. Chronic rise in defibrillation threshold with a hybrid lead system. Am J Cardiol 1996;78:309-312.
    • (1996) Am J Cardiol , vol.78 , pp. 309-312
    • Tummula, R.V.1    Riggio, D.R.2    Peters, R.W.3
  • 9
    • 0031568431 scopus 로고    scopus 로고
    • Chronic rise in monophasic defibrillation thresholds with a transvenous lead system
    • Kirk MM, Shorofsky SR, Khalighi K, et al. Chronic rise in monophasic defibrillation thresholds with a transvenous lead system. Am J Cardiol 1997;79:502-505.
    • (1997) Am J Cardiol , vol.79 , pp. 502-505
    • Kirk, M.M.1    Shorofsky, S.R.2    Khalighi, K.3
  • 10
    • 0025352387 scopus 로고
    • Utility of low energy test shocks for estimation of cardiac and electrode impedance with implantable defibrillators
    • Leitch JW, Yee R, Klein GJ, et al. Utility of low energy test shocks for estimation of cardiac and electrode impedance with implantable defibrillators. PACE 1990;13:410-416.
    • (1990) PACE , vol.13 , pp. 410-416
    • Leitch, J.W.1    Yee, R.2    Klein, G.J.3
  • 11
    • 0028301696 scopus 로고
    • Effects of voltage and respiration on impedance in nonthoracotomy defibrillation pathways
    • Swerdlow CD, Kass RM, Hwang C, et al. Effects of voltage and respiration on impedance in nonthoracotomy defibrillation pathways. Am J Cardiol 1994;73:688-692.
    • (1994) Am J Cardiol , vol.73 , pp. 688-692
    • Swerdlow, C.D.1    Kass, R.M.2    Hwang, C.3
  • 12
    • 0021997027 scopus 로고
    • Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator
    • Echt DS, Armstrong D, Schmidt P, et al. Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator. Circulation 1985;71: 289-296.
    • (1985) Circulation , vol.71 , pp. 289-296
    • Echt, D.S.1    Armstrong, D.2    Schmidt, P.3
  • 13
    • 0019644588 scopus 로고
    • Determining transthoracic impedance, delivered energy and peak current during defibrillation episodes
    • Jones VC, Charbonnier FM, Long P. Determining transthoracic impedance, delivered energy and peak current during defibrillation episodes. Med Instrum 1981;15:380-382.
    • (1981) Med Instrum , vol.15 , pp. 380-382
    • Jones, V.C.1    Charbonnier, F.M.2    Long, P.3
  • 14
    • 0014092571 scopus 로고
    • Myocardial stimulation: The electrochemistry of electrode-tissue coupling
    • Mansfield PB. Myocardial stimulation: The electrochemistry of electrode-tissue coupling. Am J Physiol 1967; 212(6): 1475-1488.
    • (1967) Am J Physiol , vol.212 , Issue.6 , pp. 1475-1488
    • Mansfield, P.B.1
  • 15
    • 2342664175 scopus 로고
    • Philadelphia: W.B. Saunders Co.
    • Hakki A-H. Ideal Cardiac Pacing. Philadelphia: W.B. Saunders Co.1984, p. 41.
    • (1984) Ideal Cardiac Pacing , pp. 41
    • Hakki, A.-H.1
  • 16
    • 2342547111 scopus 로고
    • Titanium electrode anodization effects on system impedance and defibrillator output
    • Abstract
    • Derfus D, Dahl R, Heitkamp D, et al. Titanium electrode anodization effects on system impedance and defibrillator output. Eur J C. P. E. 1994;4(Abstract):119.
    • (1994) Eur J C. P. E. , vol.4 , pp. 119
    • Derfus, D.1    Dahl, R.2    Heitkamp, D.3
  • 17
    • 0028859124 scopus 로고
    • TiN: A suitable coating for defibrillator electrodes?
    • Stroetmann B, Siemsen G, Straehler B. TiN: A suitable coating for defibrillator electrodes? PACE 1995;18:237-242.
    • (1995) PACE , vol.18 , pp. 237-242
    • Stroetmann, B.1    Siemsen, G.2    Straehler, B.3
  • 19
    • 0024206230 scopus 로고
    • Strength-duration curves of fixed pulse width variable tilt truncated exponential waveforms for nonthoracotomy internal defibrillation in dogs
    • Chapman PD, Wetherbee JN, Vetter JW, et al. Strength-duration curves of fixed pulse width variable tilt truncated exponential waveforms for nonthoracotomy internal defibrillation in dogs. PACE 1988;11:1045-1050.
    • (1988) PACE , vol.11 , pp. 1045-1050
    • Chapman, P.D.1    Wetherbee, J.N.2    Vetter, J.W.3
  • 20
    • 0030813795 scopus 로고    scopus 로고
    • Strength-duration relationship for human transvenous defibrillation
    • Gold MR, Shorofsky SR. Strength-duration relationship for human transvenous defibrillation. Circulation 1997;96: 3517-3520.
    • (1997) Circulation , vol.96 , pp. 3517-3520
    • Gold, M.R.1    Shorofsky, S.R.2
  • 22
    • 0027171761 scopus 로고
    • A simplified, single-lead unipolar transvenous cardioversion-defibrillation system
    • Bardy GH, Johnson G, Poole JE, et al. A simplified, single-lead unipolar transvenous cardioversion-defibrillation system. Circulation 1993;88:543-547.
    • (1993) Circulation , vol.88 , pp. 543-547
    • Bardy, G.H.1    Johnson, G.2    Poole, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.