메뉴 건너뛰기




Volumn 81, Issue 1, 1999, Pages 25-36

Patient dosimetry in arteriography of the lower limbs. Part I: Quantification of exposure

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTERIOGRAPHY; ARTICLE; CATHETERIZATION; COMPUTER PROGRAM; DOSIMETRY; FEMALE; FLUOROSCOPY; HUMAN; INFORMATION PROCESSING; LEG; MAJOR CLINICAL STUDY; MALE; NEEDLE; PATIENT; PERIPHERAL CIRCULATION; POSITION; PUNCTURE; RADIATION EXPOSURE; X RAY; X RAY TUBE;

EID: 0032928436     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a032566     Document Type: Article
Times cited : (6)

References (14)
  • 2
    • 0030464316 scopus 로고    scopus 로고
    • Patient dose measurements from femoral angiography
    • Hoskins, P. R., Gillespie, I. and Ireland, H. M. Patient Dose Measurements from Femoral Angiography. Br. J. Radiol. 69, 1159-1164 (1996).
    • (1996) Br. J. Radiol. , vol.69 , pp. 1159-1164
    • Hoskins, P.R.1    Gillespie, I.2    Ireland, H.M.3
  • 3
    • 0029970146 scopus 로고    scopus 로고
    • A patient dose survey for femoral arteriogram diagnostic radiographic examinations using a dose-area product meter
    • Thwaites, J. H., Rafferty, M. W., Gray, N., Black J. and Stock, B. A Patient Dose Survey for Femoral Arteriogram Diagnostic Radiographic Examinations using a Dose-area Product Meter. Phys. Med. Biol. 41, 899-907 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 899-907
    • Thwaites, J.H.1    Rafferty, M.W.2    Gray, N.3    Black, J.4    Stock, B.5
  • 5
    • 0027212407 scopus 로고
    • Patient doses received during digital subtraction angiography
    • Steele, H. R. and Temperton, D. H. Patient Doses Received during Digital Subtraction Angiography. Br. J. Radiol. 66, 452-456 (1993).
    • (1993) Br. J. Radiol. , vol.66 , pp. 452-456
    • Steele, H.R.1    Temperton, D.H.2
  • 6
    • 0029048173 scopus 로고
    • Assessment of organ radiation doses and associated risk for digital bifemoral arteriography
    • Castellano, I. A., McNeill, J. G., Thorp, N. C, Dance, D. R. and Raphael, M. J. Assessment of Organ Radiation Doses and Associated Risk for Digital Bifemoral Arteriography. Br. J. Radiol. 68, 502-507 (1995).
    • (1995) Br. J. Radiol. , vol.68 , pp. 502-507
    • Castellano, I.A.1    McNeill, J.G.2    Thorp, N.C.3    Dance, D.R.4    Raphael, M.J.5
  • 7
    • 0026450935 scopus 로고
    • An automated measurement system for characterisation of patient exposure during angiography
    • Kicken, P. J., Kemerink, G. J., Vaessen, P. J. and Ackermans, J. J. An Automated Measurement System for Characterisation of Patient Exposure during Angiography. Radiat. Prot. Dosim. 43, 165-169 (1992).
    • (1992) Radiat. Prot. Dosim. , vol.43 , pp. 165-169
    • Kicken, P.J.1    Kemerink, G.J.2    Vaessen, P.J.3    Ackermans, J.J.4
  • 10
    • 84907105470 scopus 로고
    • Determination of the integral absorbed dose from exposure measurements
    • Carlsson, C. Determination of the Integral Absorbed Dose from Exposure Measurements. Acta Radiol. Ther. Phys. Biol 1, 433-458 (1963).
    • (1963) Acta Radiol. Ther. Phys. Biol , vol.1 , pp. 433-458
    • Carlsson, C.1
  • 11
    • 0345071188 scopus 로고
    • Integral absorbed doses in Roentgen diagnostic procedures
    • Carlsson, C. Integral Absorbed Doses in Roentgen Diagnostic Procedures. Acta Radiol. Ther. Phys. Biol. 3, 311-326 (1965).
    • (1965) Acta Radiol. Ther. Phys. Biol. , vol.3 , pp. 311-326
    • Carlsson, C.1
  • 12
    • 0022460403 scopus 로고
    • Relations between effective dose equivalent and mean absorbed dose (energy imparted) to patients in diagnostic radiology
    • Carlsson, G. A. and Carlsson, C. A. Relations between Effective Dose Equivalent and Mean Absorbed Dose (Energy Imparted) to Patients in Diagnostic Radiology. Phys. Med. Biol. 31, 911-921 (1986).
    • (1986) Phys. Med. Biol. , vol.31 , pp. 911-921
    • Carlsson, G.A.1    Carlsson, C.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.