메뉴 건너뛰기




Volumn 25, Issue 8, 1999, Pages 1203-1211

Effect of filling gases on the backscatter from contrast microbubbles: Theory and in vivo measurements

Author keywords

Contrast enhancement; Filling gas; In vivo dose response; Ultrasound contrast agent

Indexed keywords

ACOUSTIC WAVE BACKSCATTERING; BUBBLES (IN FLUIDS); COLOR IMAGE PROCESSING; CONTRAST MEDIA; DOPPLER EFFECT; IMAGE ENHANCEMENT; MATHEMATICAL MODELS; MEDICAL IMAGING; SURFACE ACTIVE AGENTS; ULTRASONIC TRANSDUCERS;

EID: 0032879188     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(99)00079-4     Document Type: Article
Times cited : (48)

References (33)
  • 1
    • 0344561753 scopus 로고    scopus 로고
    • The influence of environmental conditions on a new surfactant-based contrast agent, ST68
    • (in press)
    • Basude R, Duckworth J, Wheatley MA. The influence of environmental conditions on a new surfactant-based contrast agent, ST68. Ultrasound Med Biol 1999 (in press).
    • (1999) Ultrasound Med Biol
    • Basude, R.1    Duckworth, J.2    Wheatley, M.A.3
  • 2
    • 0025558229 scopus 로고
    • Intravenous contrast agent for ultrasound Doppler: In vivo measurements of small tumor vessel dose-response
    • Burns P.N., Hilpert P., Goldberg B.B. Intravenous contrast agent for ultrasound Doppler In vivo measurements of small tumor vessel dose-response . Proc Int Conf IEEE Eng Med Biol Soc. 12:1990;322-324.
    • (1990) Proc Int Conf IEEE Eng Med Biol Soc , vol.12 , pp. 322-324
    • Burns, P.N.1    Hilpert, P.2    Goldberg, B.B.3
  • 3
    • 0028985912 scopus 로고
    • The effects of an elastic solid surface layer on the radial pulsations of gas bubbles
    • Church C.C. The effects of an elastic solid surface layer on the radial pulsations of gas bubbles. J Acoust Soc Am. 97:1995;1510-1521.
    • (1995) J Acoust Soc Am , vol.97 , pp. 1510-1521
    • Church, C.C.1
  • 4
    • 0027334532 scopus 로고
    • Ultrasound scattering properties of Albunex microspheres
    • de Jong N., Hoff L. Ultrasound scattering properties of Albunex microspheres. Ultrasonics. 31:1993;175-181.
    • (1993) Ultrasonics , vol.31 , pp. 175-181
    • De Jong, N.1    Hoff, L.2
  • 6
    • 0023702838 scopus 로고
    • Transient pulsations of small gas bubble in water
    • Flynn H.G., Church C.C. Transient pulsations of small gas bubble in water. J Acoust Soc Am. 84:1988;985-998.
    • (1988) J Acoust Soc Am , vol.84 , pp. 985-998
    • Flynn, H.G.1    Church, C.C.2
  • 8
    • 0028784102 scopus 로고
    • Parenchymal enhancement and tumor visualization using a new sonographic contrast agent
    • Forsberg F., Liu J.B., Merton D.A., Rawool N.M., Goldberg B.B. Parenchymal enhancement and tumor visualization using a new sonographic contrast agent. J Ultrasound Med. 14:1995;949-957.
    • (1995) J Ultrasound Med , vol.14 , pp. 949-957
    • Forsberg, F.1    Liu, J.B.2    Merton, D.A.3    Rawool, N.M.4    Goldberg, B.B.5
  • 10
    • 0030827939 scopus 로고    scopus 로고
    • Quantitative acoustic characterization of a new surfactant based ultrasound contrast agent
    • Forsberg F., Wu Y., Makin I.R.S., Wang W., Wheatley M.A. Quantitative acoustic characterization of a new surfactant based ultrasound contrast agent. Ultrasound Med Biol. 23:1997;1201-1208.
    • (1997) Ultrasound Med Biol , vol.23 , pp. 1201-1208
    • Forsberg, F.1    Wu, Y.2    Makin, I.R.S.3    Wang, W.4    Wheatley, M.A.5
  • 11
    • 0028852824 scopus 로고
    • Quantification of intravenous contrast-enhanced Doppler power spectrum in the rabbit carotid artery
    • Frush D.P., Babcock D.S., White K.S., et al. Quantification of intravenous contrast-enhanced Doppler power spectrum in the rabbit carotid artery. Ultrasound Med Biol. 21:1995;41-47.
    • (1995) Ultrasound Med Biol , vol.21 , pp. 41-47
    • Frush, D.P.1    Babcock, D.S.2    White, K.S.3
  • 14
    • 0028285656 scopus 로고
    • Consideration about the contribution to acoustic backscatter from Albunex microspheres with different sizes
    • Hoff L., Christiansen C., Skotland T. Consideration about the contribution to acoustic backscatter from Albunex microspheres with different sizes. J Ultrasound Med. 13:1994;181-182.
    • (1994) J Ultrasound Med , vol.13 , pp. 181-182
    • Hoff, L.1    Christiansen, C.2    Skotland, T.3
  • 16
    • 0032100726 scopus 로고    scopus 로고
    • Dissolution of multicomponent microbubbles in the bloodstream: 1. Theory
    • Kabalnov A., Klein D., Pelura T., Schutt E., Weers J. Dissolution of multicomponent microbubbles in the bloodstream 1. Theory . Ultrasound Med Biol. 24:1998;739-749.
    • (1998) Ultrasound Med Biol , vol.24 , pp. 739-749
    • Kabalnov, A.1    Klein, D.2    Pelura, T.3    Schutt, E.4    Weers, J.5
  • 20
    • 0032007137 scopus 로고    scopus 로고
    • Enhancement of ultrasonically-induced hemolysis by perfluorocarbon-based compared to air-based echo-contrast agents
    • Miller D.L., Gies R.A. Enhancement of ultrasonically-induced hemolysis by perfluorocarbon-based compared to air-based echo-contrast agents. Ultrasound Med Biol. 24:1998;285-292.
    • (1998) Ultrasound Med Biol , vol.24 , pp. 285-292
    • Miller, D.L.1    Gies, R.A.2
  • 21
    • 0029556001 scopus 로고    scopus 로고
    • Contrast agents in ultrasound
    • Needleman L., Forsberg F. Contrast agents in ultrasound. Ultrasound Q. 13:1996;121-138.
    • (1996) Ultrasound Q , vol.13 , pp. 121-138
    • Needleman, L.1    Forsberg, F.2
  • 22
    • 0030183871 scopus 로고    scopus 로고
    • Reduction in left ventricular cavitary attenuation and improvement in posterior myo-cardial contrast with higher molecular weight intravenous perfluorocarbon-exposed sonicated dextrose albumin microbubbles
    • Porter T.R., Xie F., Kricsfeld A., Deligonul U., Kilzer K. Reduction in left ventricular cavitary attenuation and improvement in posterior myo-cardial contrast with higher molecular weight intravenous perfluorocarbon-exposed sonicated dextrose albumin microbubbles. J Am Soc Echocardiogr. 9:1996;437-441.
    • (1996) J Am Soc Echocardiogr , vol.9 , pp. 437-441
    • Porter, T.R.1    Xie, F.2    Kricsfeld, A.3    Deligonul, U.4    Kilzer, K.5
  • 24
    • 0027310229 scopus 로고
    • Quantitative echo contrast concentration measurement by Doppler sonography
    • Schwarz K.Q., Bezante G.P., Chen X., Schlief R. Quantitative echo contrast concentration measurement by Doppler sonography. Ultrasound Med Biol. 19:1993;289-297.
    • (1993) Ultrasound Med Biol , vol.19 , pp. 289-297
    • Schwarz, K.Q.1    Bezante, G.P.2    Chen, X.3    Schlief, R.4
  • 26
    • 0028199547 scopus 로고
    • Physics of ultrasound contrast imaging: Scattering in the linear range
    • Uhlendorf V. Physics of ultrasound contrast imaging scattering in the linear range . IEEE Trans Ultrason Ferroelec Freq Control. 41:1994;70-79.
    • (1994) IEEE Trans Ultrason Ferroelec Freq Control , vol.41 , pp. 70-79
    • Uhlendorf, V.1
  • 27
    • 0028865794 scopus 로고
    • Bubbles in circulating blood: Stabilization and simulations of cyclic changes of size and content
    • van Liew H.D., Burkard M.E. Bubbles in circulating blood stabilization and simulations of cyclic changes of size and content . J Appl Physiol. 79:1995;1379-1385.
    • (1995) J Appl Physiol , vol.79 , pp. 1379-1385
    • Van Liew, H.D.1    Burkard, M.E.2
  • 28
    • 0029043730 scopus 로고
    • Behavior of bubbles of slowly permeating gas used for ultrasonic imaging contrast
    • van Liew H.D., Burkard M.E. Behavior of bubbles of slowly permeating gas used for ultrasonic imaging contrast. Invest Radiol. 30:1995;315-321.
    • (1995) Invest Radiol , vol.30 , pp. 315-321
    • Van Liew, H.D.1    Burkard, M.E.2
  • 29
    • 0001456594 scopus 로고    scopus 로고
    • Langmuir trough study of surfactant mixtures used in the production of a new ultrasound contrast agent consisting of stabilized microbubbles
    • Wang W., Moser C.C., Wheatley M.A. Langmuir trough study of surfactant mixtures used in the production of a new ultrasound contrast agent consisting of stabilized microbubbles. J Phys Chem. 100:1996;13815-13821.
    • (1996) J Phys Chem , vol.100 , pp. 13815-13821
    • Wang, W.1    Moser, C.C.2    Wheatley, M.A.3
  • 30
    • 0029322649 scopus 로고
    • Structural studies on stabilized microbubbles: Development of a novel contrast agent for diagnostic ultrasound
    • Wheatley M.A., Singhal S. Structural studies on stabilized microbubbles development of a novel contrast agent for diagnostic ultrasound . J React Polymers. 25:1995;157-166.
    • (1995) J React Polymers , vol.25 , pp. 157-166
    • Wheatley, M.A.1    Singhal, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.