메뉴 건너뛰기




Volumn 23, Issue 8, 1999, Pages 792-796

Characterization of a magnetic bearing system and fluid properties for a continuous flow ventricular assist device

Author keywords

Continuous flow blood pump; Pump performance; Ventricular assist device

Indexed keywords

BLOOD; FIBER OPTIC SENSORS; IMPELLERS; MAGNETISM; PUMPS; ROBUST CONTROL;

EID: 0032864847     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1525-1594.1999.06425.x     Document Type: Article
Times cited : (13)

References (9)
  • 1
    • 0029092792 scopus 로고
    • System considerations favoring rotary artificial hearts with blood-immersed bearings
    • Jarvik RK. System considerations favoring rotary artificial hearts with blood-immersed bearings. Artif Organs 1995;19(7):565-70.
    • (1995) Artif Organs , vol.19 , Issue.7 , pp. 565-570
    • Jarvik, R.K.1
  • 2
    • 0030176676 scopus 로고    scopus 로고
    • Design of a magnetic bearing supported prototype centrifugal artificial heart pump
    • Allaire PE, Maslen EH, Kim HC, Bearnson GB, Olsen DB. Design of a magnetic bearing supported prototype centrifugal artificial heart pump. Tribol Trans 1996;39(3).
    • (1996) Tribol Trans , vol.39 , Issue.3
    • Allaire, P.E.1    Maslen, E.H.2    Kim, H.C.3    Bearnson, G.B.4    Olsen, D.B.5
  • 3
    • 0002966851 scopus 로고
    • Clinical effectiveness and need for long-term circulatory support
    • Washington DC: National Academy Press
    • Clinical effectiveness and need for long-term circulatory support. In: Hogness JR, Van Antwerp M, eds. The artificial heart: Prototypes, policies, and patients. Washington DC: National Academy Press, 1991:65-84.
    • (1991) The Artificial Heart: Prototypes, Policies, and Patients , pp. 65-84
    • Hogness, J.R.1    Van Antwerp, M.2
  • 4
    • 0009709823 scopus 로고    scopus 로고
    • Self sensing active magnetic bearings based on parameter estimation
    • Maslen EH, Noh MD. Self sensing active magnetic bearings based on parameter estimation. IEEE Trans Instrument Measure, 1996.
    • (1996) IEEE Trans Instrument Measure
    • Maslen, E.H.1    Noh, M.D.2
  • 5
    • 0009655966 scopus 로고    scopus 로고
    • Motor feedback physiological control for a continuous flow ventricular assist device
    • in press
    • Waters T, Allaire P, Tao G. Motor feedback physiological control for a continuous flow ventricular assist device. J Am Soc Artif Intern Organs 1998 (in press).
    • (1998) J Am Soc Artif Intern Organs
    • Waters, T.1    Allaire, P.2    Tao, G.3
  • 6
    • 0028351689 scopus 로고
    • The next generation Baylor C-Gyro pump: Antithrombogenic free impeller design for long term centrifugal VAD
    • O'Hara Y, Nosé Y. The next generation Baylor C-Gyro pump: Antithrombogenic free impeller design for long term centrifugal VAD. Artif Organs 1994;18(3):238-43.
    • (1994) Artif Organs , vol.18 , Issue.3 , pp. 238-243
    • O'Hara, Y.1    Nosé, Y.2
  • 7
    • 0031927291 scopus 로고    scopus 로고
    • Performance of a continuous flow ventricular assist device: Magnetic bearing design, construction, and testing
    • Allaire P, Hilton E, Baloh M, Maslen E, Barnson G, Noh D, Khanwilkar P, Olsen D. Performance of a continuous flow ventricular assist device: Magnetic bearing design, construction, and testing. Artif Organs 1998;22(6):475-80.
    • (1998) Artif Organs , vol.22 , Issue.6 , pp. 475-480
    • Allaire, P.1    Hilton, E.2    Baloh, M.3    Maslen, E.4    Barnson, G.5    Noh, D.6    Khanwilkar, P.7    Olsen, D.8
  • 9
    • 0009655479 scopus 로고    scopus 로고
    • Magnetic suspension test controller for a new continuous flow ventricular assist device
    • Hilton EF, Allaire PE, Baloh MB, et al. Magnetic suspension test controller for a new continuous flow ventricular assist device. Am Soc Artif Intern Organs 1998.
    • (1998) Am Soc Artif Intern Organs
    • Hilton, E.F.1    Allaire, P.E.2    Baloh, M.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.