메뉴 건너뛰기




Volumn 22, Issue 6, 1998, Pages 475-480

Performance of a continuous flow ventricular assist device: Magnetic bearing design, construction, and testing

Author keywords

Continuous flow; Magnetic bearing; Ventricular assist.

Indexed keywords

BRUSHLESS DC MOTORS; CENTRIFUGATION; ELECTRIC DRIVES; FIBER OPTIC SENSORS; IMPELLERS; MAGNETIC ACTUATORS; PERMANENT MAGNETS; SUSPENSIONS (COMPONENTS); TWO TERM CONTROL SYSTEMS;

EID: 0031927291     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1525-1594.1998.06095.x     Document Type: Article
Times cited : (34)

References (14)
  • 1
    • 8944239276 scopus 로고
    • Studies of performance and operating conditions of the centrifugal blood pump with magnetically suspended impeller
    • Akamatsu T, Yoshino Y, Tsukiya T, et al. Studies of performance and operating conditions of the centrifugal blood pump with magnetically suspended impeller. Artif Organs 1994;18:224.
    • (1994) Artif Organs , vol.18 , pp. 224
    • Akamatsu, T.1    Yoshino, Y.2    Tsukiya, T.3
  • 2
    • 0029159808 scopus 로고
    • Design of a centrifugal blood pump with magnetic suspension
    • Yamane T, Ikeda T, Orita T, et al. Design of a centrifugal blood pump with magnetic suspension. Artif Organs 1995; 19(7):625-30.
    • (1995) Artif Organs , vol.19 , Issue.7 , pp. 625-630
    • Yamane, T.1    Ikeda, T.2    Orita, T.3
  • 3
    • 0030057896 scopus 로고    scopus 로고
    • A magnetically suspended and hydrostatically stabilized centrifugal blood pump
    • Hart RM, Filipenco VG, Kung RT. A magnetically suspended and hydrostatically stabilized centrifugal blood pump. Artif Organs 1996;20(6):591-6.
    • (1996) Artif Organs , vol.20 , Issue.6 , pp. 591-596
    • Hart, R.M.1    Filipenco, V.G.2    Kung, R.T.3
  • 4
    • 9344228008 scopus 로고
    • In vitro characterization of a magnetically suspended continuous flow ventricular assist device (CFVAD)
    • Abstract
    • Kim HC, Bearnson GB, Khanwilkar PS, Olsen DB. In vitro characterization of a magnetically suspended continuous flow ventricular assist device (CFVAD). (Abstract.) Trans Am Soc Artif Intern Organs 1995;24:95.
    • (1995) Trans Am Soc Artif Intern Organs , vol.24 , pp. 95
    • Kim, H.C.1    Bearnson, G.B.2    Khanwilkar, P.S.3    Olsen, D.B.4
  • 5
    • 15444352463 scopus 로고
    • Prototype ventricular assist device supported in magnetic bearings
    • Allaire P, ed. Chicago: Technomics Publishers
    • Allaire PE, Maslen EH, Kim HC, et al. Prototype ventricular assist device supported in magnetic bearings. In: Allaire P, ed. Proceedings of MAG '95. Chicago: Technomics Publishers 1995:63-76.
    • (1995) Proceedings of MAG '95 , pp. 63-76
    • Allaire, P.E.1    Maslen, E.H.2    Kim, H.C.3
  • 6
    • 0030055691 scopus 로고    scopus 로고
    • Prototype continuous flow ventricular assist device supported on magnetic bearings
    • Allaire PE, Kim KC, Maslen EH, et al. Prototype continuous flow ventricular assist device supported on magnetic bearings. Artif Organs 1996;20(6):582-90.
    • (1996) Artif Organs , vol.20 , Issue.6 , pp. 582-590
    • Allaire, P.E.1    Kim, K.C.2    Maslen, E.H.3
  • 7
    • 0030176676 scopus 로고    scopus 로고
    • Design of a magnetic bearing-supported prototype centrifugal artificial heart pump
    • Allaire PE, Maslen EH, Kim HC, et al. Design of a magnetic bearing-supported prototype centrifugal artificial heart pump. Trans Soc Tribol Lub Engineers 1996;39(3):663-9.
    • (1996) Trans Soc Tribol Lub Engineers , vol.39 , Issue.3 , pp. 663-669
    • Allaire, P.E.1    Maslen, E.H.2    Kim, H.C.3
  • 8
    • 15444354816 scopus 로고    scopus 로고
    • Pulsatile operation of a centrifugal ventricular assist device with magnetic bearings
    • in press
    • Bearnson GB, Olsen DB, Khanwilkar PS, et al. Pulsatile operation of a centrifugal ventricular assist device with magnetic bearings. Artif Organs (in press).
    • Artif Organs
    • Bearnson, G.B.1    Olsen, D.B.2    Khanwilkar, P.S.3
  • 9
    • 15444344448 scopus 로고    scopus 로고
    • A computer model of a physiological controller for a centrifugal VAD with magnetic bearings
    • Bearnson GB, Olsen DB, Khanwilkar PS, et al. A computer model of a physiological controller for a centrifugal VAD with magnetic bearings. ASAIO J 1997;43(2):52.
    • (1997) ASAIO J , vol.43 , Issue.2 , pp. 52
    • Bearnson, G.B.1    Olsen, D.B.2    Khanwilkar, P.S.3
  • 10
    • 0030054588 scopus 로고    scopus 로고
    • Using hybrid magnetic bearings to completely suspend the impeller of a ventricular assist device
    • Khanwilkar P, Olsen DB, Bearnson G, et al. Using hybrid magnetic bearings to completely suspend the impeller of a ventricular assist device. Artif Organs 1996;20(6):597-604.
    • (1996) Artif Organs , vol.20 , Issue.6 , pp. 597-604
    • Khanwilkar, P.1    Olsen, D.B.2    Bearnson, G.3
  • 11
    • 15444348331 scopus 로고    scopus 로고
    • Design and testing of magnetic bearing system for continuous flow ventricular assist device CFVAD III
    • Abst.
    • Baloh M, Allaire P, Maslen E, et al. Design and testing of magnetic bearing system for continuous flow ventricular assist device CFVAD III. Abst. ASAIO J 1997;43(2):64.
    • (1997) ASAIO J , vol.43 , Issue.2 , pp. 64
    • Baloh, M.1    Allaire, P.2    Maslen, E.3
  • 12
    • 0031238930 scopus 로고    scopus 로고
    • Magnetic suspension controls for continuous flow ventricular assist device CFVAD III
    • Hilton E, Allaire P, Baloh M, et al. Magnetic suspension controls for continuous flow ventricular assist device CFVAD III. ASAIO J 1997;43(5):M598-M602.
    • (1997) ASAIO J , vol.43 , Issue.5
    • Hilton, E.1    Allaire, P.2    Baloh, M.3
  • 13
    • 15444347424 scopus 로고    scopus 로고
    • Continuous flow magnetically suspended centrifugal pump for ventricular assist device (CFVAD III): Design and testing
    • presented at 5th Congress of the International Society of Rotary Blood Pumps. Providence, RI, September (in press)
    • Allaire P, Bearnson G, Flack R, et al. Continuous flow magnetically suspended centrifugal pump for ventricular assist device (CFVAD III): Design and testing, presented at 5th Congress of the International Society of Rotary Blood Pumps. Providence, RI, September 1997. Artif Organs (in press).
    • (1997) Artif Organs
    • Allaire, P.1    Bearnson, G.2    Flack, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.