메뉴 건너뛰기




Volumn 25, Issue 8, 1999, Pages 1177-1184

Confounding effects of myocardial background intensity and attenuation in contrast echocardiography: An in vivo study

Author keywords

Attenuation; Background intensity; Contrast echocardiography; Dogs; Infoson; Transit rate; Ultrasound

Indexed keywords

ATTENUATION; CONTRAST MEDIA; STATISTICAL METHODS;

EID: 0032854370     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(99)00080-0     Document Type: Article
Times cited : (3)

References (21)
  • 2
    • 0028818005 scopus 로고
    • Background subtraction from time-intensity curves in videodensitometry: A pitfall in flow assessment using contrast echocardiography
    • Bos L.J., Piek J.J., Spaan J.A. Background subtraction from time-intensity curves in videodensitometry a pitfall in flow assessment using contrast echocardiography . Ultrasound Med Biol. 21:1995;1211-1218.
    • (1995) Ultrasound Med Biol , vol.21 , pp. 1211-1218
    • Bos, L.J.1    Piek, J.J.2    Spaan, J.A.3
  • 3
    • 0342398226 scopus 로고    scopus 로고
    • Effects of shadowing on the time-intensity curves in contrast echocardiography: A phantom study
    • Bos L.J., Piek J.J., Spaan J.A. Effects of shadowing on the time-intensity curves in contrast echocardiography a phantom study . Ultrasound Med Biol. 22:1996;217-227.
    • (1996) Ultrasound Med Biol , vol.22 , pp. 217-227
    • Bos, L.J.1    Piek, J.J.2    Spaan, J.A.3
  • 4
    • 0029115032 scopus 로고
    • Fluorescent vs. radioactive measurement of regional myocardial blood flow
    • Chien G.L., Anselone C.G., Davis R.F., Van Winkle D.M. Fluorescent vs. radioactive measurement of regional myocardial blood flow. Cardiovasc Res. 30:1995;405-412.
    • (1995) Cardiovasc Res , vol.30 , pp. 405-412
    • Chien, G.L.1    Anselone, C.G.2    Davis, R.F.3    Van Winkle, D.M.4
  • 5
    • 0026830293 scopus 로고
    • Absorption and scatter of encapsulated gas filled microspheres: Theoretical considerations and some measurements
    • de Jong N., Hoff L., Skotland T., Bom N. Absorption and scatter of encapsulated gas filled microspheres theoretical considerations and some measurements . Ultrasonics. 30:1992;95-103.
    • (1992) Ultrasonics , vol.30 , pp. 95-103
    • De Jong, N.1    Hoff, L.2    Skotland, T.3    Bom, N.4
  • 6
    • 0029335544 scopus 로고
    • Cardiac cycle-dependent gray-level variation is not distorted by abnormal septal motion after cardiac surgery: A transesophageal videodensitometric study in humans
    • Gigli G., Maffei S., Picano E., et al. Cardiac cycle-dependent gray-level variation is not distorted by abnormal septal motion after cardiac surgery a transesophageal videodensitometric study in humans . J Am Soc Echocardiog. 8:1995;475-481.
    • (1995) J Am Soc Echocardiog , vol.8 , pp. 475-481
    • Gigli, G.1    Maffei, S.2    Picano, E.3
  • 7
    • 0027231021 scopus 로고
    • Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion
    • Glenny R.W., Bernard S., Brinkley M. Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion. J Appl Physiol. 74:1993;2585-2597.
    • (1993) J Appl Physiol , vol.74 , pp. 2585-2597
    • Glenny, R.W.1    Bernard, S.2    Brinkley, M.3
  • 8
    • 0029814045 scopus 로고    scopus 로고
    • Relation between air-filled albumin microbubble and red blood cell rheology in the human myocardium. Influence of echocardiographic systems and chest wall attenuation
    • Ismail S., Jayaweera A.R., Camarano G., et al. Relation between air-filled albumin microbubble and red blood cell rheology in the human myocardium. Influence of echocardiographic systems and chest wall attenuation. Circulation. 94:1996;445-451.
    • (1996) Circulation , vol.94 , pp. 445-451
    • Ismail, S.1    Jayaweera, A.R.2    Camarano, G.3
  • 9
    • 0028308410 scopus 로고
    • In vivo myocardial kinetics of air-filled albumin microbubbles during myocardial contrast echocardiography. Comparison with radiolabeled red blood cells
    • Jayaweera A.R., Edwards N., Glasheen W.P., et al. In vivo myocardial kinetics of air-filled albumin microbubbles during myocardial contrast echocardiography. Comparison with radiolabeled red blood cells. Circ Res. 74:1994;1157-1165.
    • (1994) Circ Res , vol.74 , pp. 1157-1165
    • Jayaweera, A.R.1    Edwards, N.2    Glasheen, W.P.3
  • 10
    • 0028542185 scopus 로고
    • Attenuation deforms time-intensity curves during contrast echocardiography: Implications for assessment of mean transit rates
    • Jayaweera A.R., Ismail S., Kaul S. Attenuation deforms time-intensity curves during contrast echocardiography implications for assessment of mean transit rates . J Am Soc Echocardiog. 7:1994;590-597.
    • (1994) J Am Soc Echocardiog , vol.7 , pp. 590-597
    • Jayaweera, A.R.1    Ismail, S.2    Kaul, S.3
  • 11
    • 0029876404 scopus 로고    scopus 로고
    • Cyclic variation in myocardial gray level as a marker of viability in man. A videodensitometric study
    • Marini C., Picano E., Varga A., et al. Cyclic variation in myocardial gray level as a marker of viability in man. A videodensitometric study. Eur Heart J. 17:1996;472-479.
    • (1996) Eur Heart J , vol.17 , pp. 472-479
    • Marini, C.1    Picano, E.2    Varga, A.3
  • 12
    • 0027441881 scopus 로고
    • Digital radiofrequency echocardiography in the detection of myocardial contrast following intravenous administration of Albunex
    • Monaghan M.J., Metcalfe J.M., Odunlami S., et al. Digital radiofrequency echocardiography in the detection of myocardial contrast following intravenous administration of Albunex. Eur Heart J. 14:1993;1200-1209.
    • (1993) Eur Heart J , vol.14 , pp. 1200-1209
    • Monaghan, M.J.1    Metcalfe, J.M.2    Odunlami, S.3
  • 13
    • 0027412018 scopus 로고
    • Myocardial contrast echocardiography for the assessment of coronary blood flow reserve: Validation in humans
    • Porter T.R., D'Sa A., Turner C., et al. Myocardial contrast echocardiography for the assessment of coronary blood flow reserve validation in humans . J Am Coll Cardiol. 21:1993;349-355.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 349-355
    • Porter, T.R.1    D'Sa, A.2    Turner, C.3
  • 14
    • 85047678005 scopus 로고
    • Development in non-radioactive microsphere techniques for blood flow measurements
    • Prinzen F.W., Glenny R.W. Development in non-radioactive microsphere techniques for blood flow measurements. Cardiovasc Res. 28:1994;1467-1475.
    • (1994) Cardiovasc Res , vol.28 , pp. 1467-1475
    • Prinzen, F.W.1    Glenny, R.W.2
  • 15
    • 0028872215 scopus 로고
    • A proposed microscopic elastic wave theory for ultrasonic backscatter from myocardial tissue
    • Rose J.H., Kaufmann M.R., Wickline S.A., Hall C.S., Miller J.G. A proposed microscopic elastic wave theory for ultrasonic backscatter from myocardial tissue. J Acoust Soc Am. 97:1995;656-668.
    • (1995) J Acoust Soc Am , vol.97 , pp. 656-668
    • Rose, J.H.1    Kaufmann, M.R.2    Wickline, S.A.3    Hall, C.S.4    Miller, J.G.5
  • 16
    • 0027433381 scopus 로고
    • Intracoronary air-filled albumin microspheres for myocardial blood flow measurement
    • Rovai D., Ghelardini G., Trivella M.G., et al. Intracoronary air-filled albumin microspheres for myocardial blood flow measurement. J Am Coll Cardiol. 22:1993;2014-2021.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 2014-2021
    • Rovai, D.1    Ghelardini, G.2    Trivella, M.G.3
  • 17
    • 0028129040 scopus 로고
    • Quantification of myocardial perfusion with myocardial contrast echocardiography during left atrial injection of contrast. Implications for venous injection
    • Skyba D.M., Jayaweera A.R., Goodman N.C., et al. Quantification of myocardial perfusion with myocardial contrast echocardiography during left atrial injection of contrast. Implications for venous injection. Circulation. 90:1994;1513-1521.
    • (1994) Circulation , vol.90 , pp. 1513-1521
    • Skyba, D.M.1    Jayaweera, A.R.2    Goodman, N.C.3
  • 18
    • 0019457699 scopus 로고
    • Forward coronary flow normally seen in systole is the result of both forward and concealed back flow
    • Spaan J.A., Breuls N.P., Laird J.D. Forward coronary flow normally seen in systole is the result of both forward and concealed back flow. Basic Res Cardiol. 76:1981;582-586.
    • (1981) Basic Res Cardiol , vol.76 , pp. 582-586
    • Spaan, J.A.1    Breuls, N.P.2    Laird, J.D.3
  • 19
    • 0022414680 scopus 로고
    • Artifactual regional gray level variability in contrast-enhanced two-dimensional echocardiographic images: Effect on measurement of the coronary perfusion bed
    • Taylor A.L., Collins S.M., Skorton D.J., et al. Artifactual regional gray level variability in contrast-enhanced two-dimensional echocardiographic images effect on measurement of the coronary perfusion bed . J Am Coll Cardiol. 6:1985;831-838.
    • (1985) J Am Coll Cardiol , vol.6 , pp. 831-838
    • Taylor, A.L.1    Collins, S.M.2    Skorton, D.J.3
  • 20
    • 0029097678 scopus 로고
    • Validation of fluorescent microsphere technique for measurement of organ perfusion with improved aample processing method
    • Van Oosterhout M.F.M., Willigers H.M.M., Reneman R.S., Prinzen F.W. Validation of fluorescent microsphere technique for measurement of organ perfusion with improved aample processing method. Am J Physiol. 296:1995;H725-H733.
    • (1995) Am J Physiol , vol.296
    • Van Oosterhout, M.F.M.1    Willigers, H.M.M.2    Reneman, R.S.3    Prinzen, F.W.4
  • 21
    • 0028471176 scopus 로고
    • Myocardial contrast enhancement after intravenous injection of sonicated albumin microbubbles: A transesophageal echocardiography dipyridamole study
    • Voci P., Bilotta F., Merialdo P., Agati L. Myocardial contrast enhancement after intravenous injection of sonicated albumin microbubbles a transesophageal echocardiography dipyridamole study . J Am Soc Echocardiog. 7:1994;337-346.
    • (1994) J Am Soc Echocardiog , vol.7 , pp. 337-346
    • Voci, P.1    Bilotta, F.2    Merialdo, P.3    Agati, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.