메뉴 건너뛰기




Volumn 94, Issue 3, 1996, Pages 445-451

Relation between air-filled albumin microbubble and red blood cell rheology in the human myocardium: Influence of echocardiographic systems and chest wall attenuation

Author keywords

blood flow; contrast media; echocardiography

Indexed keywords

ALBUMIN; CONTRAST MEDIUM;

EID: 0029814045     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.94.3.445     Document Type: Article
Times cited : (51)

References (33)
  • 1
    • 0013626170 scopus 로고
    • Assessment of myocardial perfusion with contrast two-dimensional echocardiography
    • Weyman AE, ed. Lea & Febiger;
    • Kaul S, Force T. Assessment of myocardial perfusion with contrast two-dimensional echocardiography. In: Weyman AE, ed. Principles and Practice of Echocardiography, 2nd ed. Lea & Febiger; 1993: 687-720.
    • (1993) Principles and Practice of Echocardiography, 2nd Ed. , pp. 687-720
    • Kaul, S.1    Force, T.2
  • 2
    • 0027103789 scopus 로고
    • An association between collateral blood flow and myocardial viability in patients with recent myocardial infarction
    • Sabia PJ, Powers ER, Ragosta M, Sarembock IJ, Burwell L, Kaul S. An association between collateral blood flow and myocardial viability in patients with recent myocardial infarction. N Engl J Med. 1992;372:1825-1831.
    • (1992) N Engl J Med , vol.372 , pp. 1825-1831
    • Sabia, P.J.1    Powers, E.R.2    Ragosta, M.3    Sarembock, I.J.4    Burwell, L.5    Kaul, S.6
  • 3
    • 0028272464 scopus 로고
    • Microvascular integrity indicates myocellular viability in pa tients with recent myocardial infarction: New insights using myocardial contrast echocardiography
    • Ragosta M, Camarano GP, Kaul S, Powers E, Sarembock IJ, Gimple LW. Microvascular integrity indicates myocellular viability in pa tients with recent myocardial infarction: new insights using myocardial contrast echocardiography. Circulation. 1994;89:2562-2569.
    • (1994) Circulation , vol.89 , pp. 2562-2569
    • Ragosta, M.1    Camarano, G.P.2    Kaul, S.3    Powers, E.4    Sarembock, I.J.5    Gimple, L.W.6
  • 4
    • 0027742893 scopus 로고
    • Quantification of myocardial blood flow with contrast echocardiography
    • Jayaweera AR, Kaul S. Quantification of myocardial blood flow with contrast echocardiography. Am J Card Imaging. 1993;7:317-335.
    • (1993) Am J Card Imaging , vol.7 , pp. 317-335
    • Jayaweera, A.R.1    Kaul, S.2
  • 5
    • 0024351314 scopus 로고
    • R: A safe and effective commercially produced agent for myocardial contrast echocardiography
    • R: a safe and effective commercially produced agent for myocardial contrast echocardiography. J Am Soc Echocardiogr. 1989;2:48-52.
    • (1989) J Am Soc Echocardiogr , vol.2 , pp. 48-52
    • Keller, M.W.1    Glasheen, W.P.2    Kaul, S.3
  • 6
    • 0027368380 scopus 로고
    • Intracoronary Albunex: Its effect on left ventricular hemodynamics, function, and coronary sinus flow in humans
    • Ten Cate FJ, Widimsky P, Cornel JH, Waldstein DJ, Serruys PW, Waaler A. Intracoronary Albunex: its effect on left ventricular hemodynamics, function, and coronary sinus flow in humans. Circulation. 1993;88:2123-2127.
    • (1993) Circulation , vol.88 , pp. 2123-2127
    • Ten Cate, F.J.1    Widimsky, P.2    Cornel, J.H.3    Waldstein, D.J.4    Serruys, P.W.5    Waaler, A.6
  • 7
    • 0024392826 scopus 로고
    • The behavior of sonicated albumin microbubbles within the microcirculation: A basis for their use during myocardial contrast echocardiography
    • Keller MW, Segal SS, Kaul S, Duling BR. The behavior of sonicated albumin microbubbles within the microcirculation: a basis for their use during myocardial contrast echocardiography. Circ Res. 1989;65: 458-467.
    • (1989) Circ Res , vol.65 , pp. 458-467
    • Keller, M.W.1    Segal, S.S.2    Kaul, S.3    Duling, B.R.4
  • 8
    • 0028308410 scopus 로고
    • In-vivo myocardial kinetics of air-filled albumin micro-bubbles during myocardial contrast echocardiography: Comparison with radiolabeled red blood cells
    • Jayaweera AR, Edwards N, Glasheen WP, Villanueva FS, Abbott RD, Kaul S. In-vivo myocardial kinetics of air-filled albumin micro-bubbles during myocardial contrast echocardiography: comparison with radiolabeled red blood cells. Circ Res. 1994;74:1157-1165.
    • (1994) Circ Res , vol.74 , pp. 1157-1165
    • Jayaweera, A.R.1    Edwards, N.2    Glasheen, W.P.3    Villanueva, F.S.4    Abbott, R.D.5    Kaul, S.6
  • 9
    • 0029337248 scopus 로고
    • Integrated backscatter and digital acquisition for myocardial contrast echocardiography: Is there an advantage over conventional echocardiography for determining the mean microbubble transit rate from intracoronary injections?
    • Ismail S, Jayaweera AR, Skyba DM, Sklenar J, Goodman NC, Kaul S. Integrated backscatter and digital acquisition for myocardial contrast echocardiography: is there an advantage over conventional echocardiography for determining the mean microbubble transit rate from intracoronary injections? J Am Soc Echocardiogr. 1995;6:453-464.
    • (1995) J Am Soc Echocardiogr , vol.6 , pp. 453-464
    • Ismail, S.1    Jayaweera, A.R.2    Skyba, D.M.3    Sklenar, J.4    Goodman, N.C.5    Kaul, S.6
  • 10
    • 0029266011 scopus 로고
    • Technical factors that influence the determination of microbubble transit rate during contrast echocardiography
    • Jayaweera AR, Skyba DM, Kaul S. Technical factors that influence the determination of microbubble transit rate during contrast echocardiography. J Am Soc Echocardiogr. 1995;8:198-206.
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 198-206
    • Jayaweera, A.R.1    Skyba, D.M.2    Kaul, S.3
  • 11
    • 0026033054 scopus 로고
    • Clinical validation of a miniature nuclear probe system for continuous on-line monitoring of cardiac function and ST segment
    • Broadhurst P, Cashman P, Crawley J, Raftery E, Lahiri A. Clinical validation of a miniature nuclear probe system for continuous on-line monitoring of cardiac function and ST segment. J Nucl Med. 1991; 32:37-43.
    • (1991) J Nucl Med , vol.32 , pp. 37-43
    • Broadhurst, P.1    Cashman, P.2    Crawley, J.3    Raftery, E.4    Lahiri, A.5
  • 14
    • 0016749055 scopus 로고
    • Red blood cell velocity profiles in the arterioles and venules of the rabbit omentum
    • Schmid-Schoenbein GW, Zweifach BW. Red blood cell velocity profiles in the arterioles and venules of the rabbit omentum. Microvasc Res. 1975;10:153-164.
    • (1975) Microvasc Res , vol.10 , pp. 153-164
    • Schmid-Schoenbein, G.W.1    Zweifach, B.W.2
  • 15
    • 0015275666 scopus 로고
    • Ratio of red cell velocities near the vessel wall to velocities in the vessel center in cerebral microcirculation and an apparent effect of blood viscosity on this ratio
    • Rosenblum WI. Ratio of red cell velocities near the vessel wall to velocities in the vessel center in cerebral microcirculation and an apparent effect of blood viscosity on this ratio. Microvasc Res. 1972; 4:98-101.
    • (1972) Microvasc Res , vol.4 , pp. 98-101
    • Rosenblum, W.I.1
  • 16
    • 0025612337 scopus 로고
    • Intravenous contrast echocardiography with use of sonicated albumin in humans: Systolic disappearance of left ventricular contrast after transpulmonary transmission
    • Shapiro JR, Reisner SA, Lichtenberg GS, Meltzer RS. Intravenous contrast echocardiography with use of sonicated albumin in humans: systolic disappearance of left ventricular contrast after transpulmonary transmission. J Am Coll Cardiol. 1990;16:1603-1607.
    • (1990) J Am Coll Cardiol , vol.16 , pp. 1603-1607
    • Shapiro, J.R.1    Reisner, S.A.2    Lichtenberg, G.S.3    Meltzer, R.S.4
  • 17
    • 0003999225 scopus 로고
    • State College, Pa: The Pennsylvania State University Press
    • Albers VM. Underwater Acoustic Handbook. State College, Pa: The Pennsylvania State University Press; 1960.
    • (1960) Underwater Acoustic Handbook
    • Albers, V.M.1
  • 18
    • 0028882611 scopus 로고
    • Transient myocardial contrast after initial exposure to diagnostic ultrasound pressures with minute doses of intravenously injected microbubbles: Demonstration of potential mechanisms
    • Porter TR, Xie F. Transient myocardial contrast after initial exposure to diagnostic ultrasound pressures with minute doses of intravenously injected microbubbles: demonstration of potential mechanisms. Circulation. 1995;92:2391-2395.
    • (1995) Circulation , vol.92 , pp. 2391-2395
    • Porter, T.R.1    Xie, F.2
  • 19
    • 0028129040 scopus 로고
    • Quantification of myocardial perfusion with myocardial con trast echocardiography from left atrial injection of contrast: Implications for venous injection
    • Skyba DM, Jayaweera AR, Goodman NC, Ismail S, Camarano GP, Kaul S. Quantification of myocardial perfusion with myocardial con trast echocardiography from left atrial injection of contrast: implications for venous injection. Circulation. 1994;90:1513-1521.
    • (1994) Circulation , vol.90 , pp. 1513-1521
    • Skyba, D.M.1    Jayaweera, A.R.2    Goodman, N.C.3    Ismail, S.4    Camarano, G.P.5    Kaul, S.6
  • 20
    • 0027634297 scopus 로고
    • Pitfalls in quantitative contrast echocardiography: The steps to quantitation of perfusion
    • Wiencek JG, Feinstein SB, Walker R, Aronson S. Pitfalls in quantitative contrast echocardiography: the steps to quantitation of perfusion. J Am Soc Echocardiogr. 1993;6:395-416.
    • (1993) J Am Soc Echocardiogr , vol.6 , pp. 395-416
    • Wiencek, J.G.1    Feinstein, S.B.2    Walker, R.3    Aronson, S.4
  • 21
    • 0027535280 scopus 로고
    • Flow quantitation by contrast echocardiography: Effects of intervening tissue and of the angle of incidence between flow and ultrasonic beam
    • Rovai D, Lombardi M, Taddei L, Mazzarisi A, Ghelardini G, Distante A, Benassi A, L'Abbate A. Flow quantitation by contrast echocardiography: effects of intervening tissue and of the angle of incidence between flow and ultrasonic beam. Int J Card Imaging. 1993;9:21-27.
    • (1993) Int J Card Imaging , vol.9 , pp. 21-27
    • Rovai, D.1    Lombardi, M.2    Taddei, L.3    Mazzarisi, A.4    Ghelardini, G.5    Distante, A.6    Benassi, A.7    L'Abbate, A.8
  • 22
    • 0346562848 scopus 로고
    • Hemodynamic and safety characteristics of FS-069, a new contrast agent capable of producing myocardial opacification from a venous injection
    • Abstract
    • Skyba DM, Goodman C, Jayaweera AR, Ismail S, Camarano G, Bales G, Kaul S. Hemodynamic and safety characteristics of FS-069, a new contrast agent capable of producing myocardial opacification from a venous injection. J Am Soc Echocardiogr. 1994;7:S30. Abstract.
    • (1994) J Am Soc Echocardiogr , vol.7
    • Skyba, D.M.1    Goodman, C.2    Jayaweera, A.R.3    Ismail, S.4    Camarano, G.5    Bales, G.6    Kaul, S.7
  • 23
    • 0029362417 scopus 로고
    • Intravenous perfluoropropane-exposed sonicated dextrose albumin produces myocardial contrast which correlates with coronary blood flow
    • Porter T, Xie F, Kilzer K. Intravenous perfluoropropane-exposed sonicated dextrose albumin produces myocardial contrast which correlates with coronary blood flow. J Am Soc Echocardiogr. 1995; 8:710-718.
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 710-718
    • Porter, T.1    Xie, F.2    Kilzer, K.3
  • 25
    • 0026689472 scopus 로고
    • Intravascular ultrasound and intracardiac echocardiography: Concepts for the future
    • Pandian NG, Hsu TL. Intravascular ultrasound and intracardiac echocardiography: concepts for the future. Am J Cardiol. 1992;69:6H-17H.
    • (1992) Am J Cardiol , vol.69
    • Pandian, N.G.1    Hsu, T.L.2
  • 26
    • 0024592182 scopus 로고
    • Assessment of regional myocardial blood flow with myocardial contrast two-dimensional echocardiography
    • Kaul S, Kelly P, Oliner JD, Glasheen WP, Keller MW, Watson DD. Assessment of regional myocardial blood flow with myocardial contrast two-dimensional echocardiography. J Am Coll Cardiol. 1989; 13:468-482.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 468-482
    • Kaul, S.1    Kelly, P.2    Oliner, J.D.3    Glasheen, W.P.4    Keller, M.W.5    Watson, D.D.6
  • 29
    • 0024423710 scopus 로고
    • A look at 15 years of planar thallium-201 imaging
    • Kaul S. A look at 15 years of planar thallium-201 imaging. Am Heart J. 1989;118:581-601.
    • (1989) Am Heart J , vol.118 , pp. 581-601
    • Kaul, S.1
  • 31
    • 0026556933 scopus 로고
    • In vivo relation of intramyocardial blood volume to myocardial perfusion: Evidence supporting microvascular site for autoregulation
    • Wu X, Ewert DL, Liu Y, Ritman EL. In vivo relation of intramyocardial blood volume to myocardial perfusion: evidence supporting microvascular site for autoregulation. Circulation. 1992;85:730-737.
    • (1992) Circulation , vol.85 , pp. 730-737
    • Wu, X.1    Ewert, D.L.2    Liu, Y.3    Ritman, E.L.4
  • 32
    • 0025982138 scopus 로고
    • Digital angiographic impulse response analysis of regional myocardial perfusion: Estimation or coronary flow, flow reserve, and distribution volume by compartmental transit time measurement in a canine model
    • Eigler NL, Schuhlen H, Whiting JS, Plaff JM, Zeiher A, Gu S. Digital angiographic impulse response analysis of regional myocardial perfusion: estimation or coronary flow, flow reserve, and distribution volume by compartmental transit time measurement in a canine model. Circ Res. 1991;68:870-880.
    • (1991) Circ Res , vol.68 , pp. 870-880
    • Eigler, N.L.1    Schuhlen, H.2    Whiting, J.S.3    Plaff, J.M.4    Zeiher, A.5    Gu, S.6
  • 33
    • 0003075498 scopus 로고
    • Metabolic regulation of coronary blood flow
    • Marcus ML. New York, NJ: McGraw-Hill
    • Marcus ML. Metabolic regulation of coronary blood flow. In: Marcus ML. The Coronary Circulation in Health and Disease. New York, NJ: McGraw-Hill; 1983:65-92.
    • (1983) The Coronary Circulation in Health and Disease , pp. 65-92
    • Marcus, M.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.