-
1
-
-
0021808604
-
The automatic implantable cardioverter defibrillator: An overview
-
Mirowski M: The automatic implantable cardioverter defibrillator: An overview. J Am Coll Cardiol 6:461-466, 1985
-
(1985)
J Am Coll Cardiol
, vol.6
, pp. 461-466
-
-
Mirowski, M.1
-
2
-
-
0031298587
-
Current status of implantable cardioverter-defibrillators
-
O'Callaghan PA, Ruskin JN: Current status of implantable cardioverter-defibrillators. Curr Probl Cardiol 22:641-707, 1997
-
(1997)
Curr Probl Cardiol
, vol.22
, pp. 641-707
-
-
O'Callaghan, P.A.1
Ruskin, J.N.2
-
3
-
-
0028898951
-
In the beginning: From dogs to humans
-
Mower MM: In the beginning: From dogs to humans. PACE 18:506-511, 1995
-
(1995)
PACE
, vol.18
, pp. 506-511
-
-
Mower, M.M.1
-
4
-
-
0014816405
-
Standby automatic defibrillator: An approach to prevention of sudden cardiac death
-
Mirowski M, Mower MM, Staewen WS, et al: Standby automatic defibrillator: An approach to prevention of sudden cardiac death. Arch Intern Med 126:158-161, 1970
-
(1970)
Arch Intern Med
, vol.126
, pp. 158-161
-
-
Mirowski, M.1
Mower, M.M.2
Staewen, W.S.3
-
5
-
-
0015542181
-
Feasability and effectiveness of low-energy catheter defibrillation in man
-
Mirowski M, Mower MM, Gott VL, et al: Feasability and effectiveness of low-energy catheter defibrillation in man. Circulation 47:79-85, 1973
-
(1973)
Circulation
, vol.47
, pp. 79-85
-
-
Mirowski, M.1
Mower, M.M.2
Gott, V.L.3
-
6
-
-
0018975668
-
Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings
-
Mirowski M, Reid PR, Mower MM, et al: Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings. N Engl J Med 303:322-324, 1980
-
(1980)
N Engl J Med
, vol.303
, pp. 322-324
-
-
Mirowski, M.1
Reid, P.R.2
Mower, M.M.3
-
7
-
-
0001780782
-
Surgical techniques for implantation of the implantable cardioverer defibrillator
-
Zipes DP, Jalife J (eds): Philadelphia, PA, Saunders
-
Mahomed Y: Surgical techniques for implantation of the implantable cardioverer defibrillator, in Zipes DP, Jalife J (eds): Cardiac Electrophysiology: From Cell to Bedside (ed 2). Philadelphia, PA, Saunders, 1995, pp 1403-1412
-
(1995)
Cardiac Electrophysiology: From Cell to Bedside (Ed 2)
, pp. 1403-1412
-
-
Mahomed, Y.1
-
8
-
-
0029041673
-
Results of the international study of the implantable pacemaker cardioverter-defibrillator: A comparison of epicardial and endocardial lead systems
-
The Pacemaker-Cardioverter-Defibrillator Investigators
-
Zipes DP, Roberts D: Results of the international study of the implantable pacemaker cardioverter-defibrillator: A comparison of epicardial and endocardial lead systems - The Pacemaker-Cardioverter-Defibrillator Investigators. Circulation 92:59-65, 1995
-
(1995)
Circulation
, vol.92
, pp. 59-65
-
-
Zipes, D.P.1
Roberts, D.2
-
10
-
-
0016259004
-
Prehospital ventricular defibrillation. Prognosis and follow-up course
-
Liberthson RR, Nagel EL, Hirschman JC, et al: Prehospital ventricular defibrillation. Prognosis and follow-up course. N Engl J Med 291:317-321, 1974
-
(1974)
N Engl J Med
, vol.291
, pp. 317-321
-
-
Liberthson, R.R.1
Nagel, E.L.2
Hirschman, J.C.3
-
11
-
-
0016203161
-
Survival after resuscitation from out-of-hospital ventricular fibrillation
-
Baum RS, Alvarez H, Cobb LA: Survival after resuscitation from out-of-hospital ventricular fibrillation. Circulation 50:1231-1235, 1974
-
(1974)
Circulation
, vol.50
, pp. 1231-1235
-
-
Baum, R.S.1
Alvarez, H.2
Cobb, L.A.3
-
12
-
-
0019307544
-
Sudden cardiac death. I. A decade's experience with out-of-hospital resuscitation
-
Cobb LA, Werner JA, Trobaugh GB: Sudden cardiac death. I. A decade's experience with out-of-hospital resuscitation. Mod Concepts Cardiovasc Dis 49:31-36, 1980
-
(1980)
Mod Concepts Cardiovasc Dis
, vol.49
, pp. 31-36
-
-
Cobb, L.A.1
Werner, J.A.2
Trobaugh, G.B.3
-
13
-
-
0027495655
-
Sudden cardiac death: Epidemiology, transient risk, and intervention assessment
-
Myerburg RJ, Kessler KM, Castellanos A: Sudden cardiac death: Epidemiology, transient risk, and intervention assessment. Ann Intern Med 119:1187-1199, 1993
-
(1993)
Ann Intern Med
, vol.119
, pp. 1187-1199
-
-
Myerburg, R.J.1
Kessler, K.M.2
Castellanos, A.3
-
14
-
-
0024321898
-
Preliminary report: Effect of encainide and flecainide on mortality in a randomized trial of arrhythmia suppression after myocardial infarction
-
The Cardiac Arrhythmia Suppression Trial (CAST) Investigators: Preliminary report: Effect of encainide and flecainide on mortality in a randomized trial of arrhythmia suppression after myocardial infarction. N Engl J Med 32:406-412, 1989
-
(1989)
N Engl J Med
, vol.32
, pp. 406-412
-
-
-
15
-
-
0029840199
-
The coming of age of the class III antiarrhythmic principle: Retrospective and future trends
-
Singh BN: The coming of age of the class III antiarrhythmic principle: Retrospective and future trends. Am J Cardiol 78:17-27, 1996 (suppl 4A)
-
(1996)
Am J Cardiol
, vol.78
, Issue.SUPPL. 4A
, pp. 17-27
-
-
Singh, B.N.1
-
16
-
-
0028934270
-
Are implantable cardioverter-defibrillators better than conventional antiarrhythmic drugs for survivors of cardiac arrests?
-
Zipes DP: Are implantable cardioverter-defibrillators better than conventional antiarrhythmic drugs for survivors of cardiac arrests? Circulation 91:2115-2117, 1995
-
(1995)
Circulation
, vol.91
, pp. 2115-2117
-
-
Zipes, D.P.1
-
17
-
-
0030774195
-
Drugs versus devices in controlling ventricular tachycardia, ventricular fibrillation and recurrent cardiac arrest
-
Haverkamp W, Eckardt L, Borggrefe M, Breithardt G: Drugs versus devices in controlling ventricular tachycardia, ventricular fibrillation and recurrent cardiac arrest. Am J Cardiol 80:67G-73G, 1997
-
(1997)
Am J Cardiol
, vol.80
-
-
Haverkamp, W.1
Eckardt, L.2
Borggrefe, M.3
Breithardt, G.4
-
18
-
-
0027173768
-
Do patients with an implantable defibrillator live longer?
-
Bocker D, Block M, Isbruch F, et al: Do patients with an implantable defibrillator live longer? J Am Coll Cardiol 21:1638-1644, 1993
-
(1993)
J Am Coll Cardiol
, vol.21
, pp. 1638-1644
-
-
Bocker, D.1
Block, M.2
Isbruch, F.3
-
19
-
-
0029899696
-
Comparison of d,1-sotalol and implantable defibrillators for treatment of sustained ventricular tachycardia or fibrillation in patients with coronary artery disease
-
Bocker D, Haverkamp W, Block M, et al: Comparison of d,1-sotalol and implantable defibrillators for treatment of sustained ventricular tachycardia or fibrillation in patients with coronary artery disease. Circulation 94:151-157, 1996
-
(1996)
Circulation
, vol.94
, pp. 151-157
-
-
Bocker, D.1
Haverkamp, W.2
Block, M.3
-
20
-
-
85077806138
-
Heart failure and arrhythmia: Results from the Canadian Implantable Defibrillator Study
-
Connolly SJ: Heart failure and arrhythmia: Results from the Canadian Implantable Defibrillator Study. American College of Cardiology Meeting, 1998. http://www.medscape.com/medscape/CNO/1998/ ACC/03.30/acco405.conn/acco405.conn.html
-
(1998)
American College of Cardiology Meeting
-
-
Connolly, S.J.1
-
21
-
-
0027527346
-
Canadian implantable defibrillator study (CIDS): Study design and organization
-
Connolly SJ, Gent M, Roberts RS, et al, on behalf of the CIDS Co-investigators: Canadian implantable defibrillator study (CIDS): Study design and organization. Am J Cardiol 72:103F-108F, 1993
-
(1993)
Am J Cardiol
, vol.72
-
-
Connolly, S.J.1
Gent, M.2
Roberts, R.S.3
-
22
-
-
0028957354
-
Antiarrhythmics versus implantable defibrillators (AVID): Rationale, design and methods
-
The AVID Investigators: Antiarrhythmics versus implantable defibrillators (AVID): Rationale, design and methods. Am J Cardiol 75:470-475, 1995
-
(1995)
Am J Cardiol
, vol.75
, pp. 470-475
-
-
-
23
-
-
9844224486
-
A comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from near-fatal sustained ventricular arrhythmias
-
The Antiarrhythmics Versus Implantable Defibrillators (AVID) Investigators: A comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from near-fatal sustained ventricular arrhythmias. N Engl J Med 337:1576-1583, 1997
-
(1997)
N Engl J Med
, vol.337
, pp. 1576-1583
-
-
-
24
-
-
0028208665
-
Implantable cardioverter defibrillator compared with antiarrhythmic drug treatment in cardiac arrest survivors
-
the Cardiac Arrest Study Hamburg
-
Siebels J, Kuck KH, and the CASH Investigators: Implantable cardioverter defibrillator compared with antiarrhythmic drug treatment in cardiac arrest survivors (the Cardiac Arrest Study Hamburg). Am Heart J 127:1139-1144, 1994
-
(1994)
Am Heart J
, vol.127
, pp. 1139-1144
-
-
Siebels, J.1
Kuck, K.H.2
-
25
-
-
0027380237
-
Preliminary results of the cardiac arrest study Hamburg (CASH)
-
Siebels J, Cappato R, Ruppel R, et al, and the CASH Investigators: Preliminary results of the cardiac arrest study Hamburg (CASH). Am J Cardiol 72:109F-113F, 1993
-
(1993)
Am J Cardiol
, vol.72
-
-
Siebels, J.1
Cappato, R.2
Ruppel, R.3
-
26
-
-
0006918490
-
Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia
-
Moss AJ, Hall WJ, Cannom DS, et al, for the Multicenter Automatic Defibrillator Implantation Trial Investigators: Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. N Engl J Med 335:1933-1940, 1996
-
(1996)
N Engl J Med
, vol.335
, pp. 1933-1940
-
-
Moss, A.J.1
Hall, W.J.2
Cannom, D.S.3
-
27
-
-
0027176410
-
The Coronary Artery Bypass Graft (CABG) Patch Trial
-
The CABG Patch Investigators and Coordinators: The Coronary Artery Bypass Graft (CABG) Patch Trial. Prog Cardiovasc Dis 36:97-114, 1993
-
(1993)
Prog Cardiovasc Dis
, vol.36
, pp. 97-114
-
-
-
28
-
-
0031911231
-
A review of the implantable cardioverter defibrillator trials
-
Cannom DS: A review of the implantable cardioverter defibrillator trials. Curr Opin Cardiol 13:3-8, 1998
-
(1998)
Curr Opin Cardiol
, vol.13
, pp. 3-8
-
-
Cannom, D.S.1
-
29
-
-
0027254643
-
Influence of implantable cardioverter-defibrillators on the long-term prognosis of survivors of out-of-hospital cardiac arrest
-
Powell AC, Fuchs T, Finkelstein DM, et al: Influence of implantable cardioverter-defibrillators on the long-term prognosis of survivors of out-of-hospital cardiac arrest. Circulation 88:1083-1092, 1993
-
(1993)
Circulation
, vol.88
, pp. 1083-1092
-
-
Powell, A.C.1
Fuchs, T.2
Finkelstein, D.M.3
-
30
-
-
0031572171
-
There should never be another Antiarrhythmics Versus Implantable Defibrillator (AVID) trial
-
Singer I, Nisam S: There should never be another Antiarrhythmics Versus Implantable Defibrillator (AVID) trial. Am J Cardiol 80:766-768, 1997
-
(1997)
Am J Cardiol
, vol.80
, pp. 766-768
-
-
Singer, I.1
Nisam, S.2
-
31
-
-
0029664632
-
Implantable cardioverterdefibrillators are preferable to drugs: A primary therapy in sustained ventricular tachyarrhythmias
-
Saksena S, Madan N, Lewis C: Implantable cardioverterdefibrillators are preferable to drugs: A primary therapy in sustained ventricular tachyarrhythmias. Prog Cardiovasc Dis 38:445-454, 1996
-
(1996)
Prog Cardiovasc Dis
, vol.38
, pp. 445-454
-
-
Saksena, S.1
Madan, N.2
Lewis, C.3
-
32
-
-
0031057396
-
Defibrillators are superior to antiarrhythmic drugs in the treatment of ventricular tachyarrhythmias
-
Bocker D, Block M, Borggrefe M, et al: Defibrillators are superior to antiarrhythmic drugs in the treatment of ventricular tachyarrhythmias. Eur Heart J 18:26-30, 1997
-
(1997)
Eur Heart J
, vol.18
, pp. 26-30
-
-
Bocker, D.1
Block, M.2
Borggrefe, M.3
-
33
-
-
0032053695
-
ACC/AHA Guidelines for implantation of cardiac pacemakers and antiarrhythmia devices: Executive summary
-
Gregoratos G, Cheitlin MD, Conill A, et al: ACC/AHA Guidelines for implantation of cardiac pacemakers and antiarrhythmia devices: Executive summary. J Am Coll Cardiol 31:1175-1206, 1998
-
(1998)
J Am Coll Cardiol
, vol.31
, pp. 1175-1206
-
-
Gregoratos, G.1
Cheitlin, M.D.2
Conill, A.3
-
34
-
-
0030041635
-
Tachyarrhythmias sensing and detection
-
Singer I (ed): Implantable cardioverter-defibrillators: Prospective comparison of different lead system-device combinations
-
Olsen WH: Tachyarrhythmias sensing and detection, in Singer I (ed): Implantable cardioverter-defibrillators: Prospective comparison of different lead system-device combinations. Circulation 93:91-98, 1996
-
(1996)
Circulation
, vol.93
, pp. 91-98
-
-
Olsen, W.H.1
-
35
-
-
85077805960
-
-
St Paul, Minnesota, CPI, chapt 3, Tachyarrhythmia detection
-
Guidant Corportion/Cardiac Pacemakers (CPI): Ventak® Mini™ Physician's System Manual. St Paul, Minnesota, CPI, chapt 3, Tachyarrhythmia detection
-
Ventak® Mini™ Physician's System Manual
-
-
-
36
-
-
0028296757
-
Effect of biphasic waveform pulse on endocardial defibrillation efficacy in humans
-
Neuzner J, Pitschner HF, Huth C, et al: Effect of biphasic waveform pulse on endocardial defibrillation efficacy in humans. Pacing Clin Electrophysiol 17:207-212, 1994
-
(1994)
Pacing Clin Electrophysiol
, vol.17
, pp. 207-212
-
-
Neuzner, J.1
Pitschner, H.F.2
Huth, C.3
-
37
-
-
0028124651
-
A prospectice randomised cross-over comparison of mono- and biphasic defibrillation using nonthoracotomy lead configurations in humans
-
Block M, Hammel D, Bocker D, et al: A prospectice randomised cross-over comparison of mono- and biphasic defibrillation using nonthoracotomy lead configurations in humans. J Cardiovasc Electrophysiol 5:581-590, 1994
-
(1994)
J Cardiovasc Electrophysiol
, vol.5
, pp. 581-590
-
-
Block, M.1
Hammel, D.2
Bocker, D.3
-
38
-
-
0028897807
-
Pacing techniques to terminate ventricular tachycardia
-
Rosenqvist M: Pacing techniques to terminate ventricular tachycardia. Pacing Clin Electrophysiol 18:592-598, 1995
-
(1995)
Pacing Clin Electrophysiol
, vol.18
, pp. 592-598
-
-
Rosenqvist, M.1
-
39
-
-
0028334183
-
Clinical outcome of patients with malignant ventricular tachyarrhythmias and a multiprogrammable implantable cardioverter-defibrillator implanted with or without thoracotomy: An international multicenter study
-
The PCD Investigator Group: Clinical outcome of patients with malignant ventricular tachyarrhythmias and a multiprogrammable implantable cardioverter-defibrillator implanted with or without thoracotomy: An international multicenter study. J Am Coll Cardiol 23:1521-1530, 1994
-
(1994)
J Am Coll Cardiol
, vol.23
, pp. 1521-1530
-
-
-
40
-
-
0027462986
-
Conversion rates of induced versus spontaneous ventricular tachycardia by a third-generation cardioverter defibrillator
-
Porterfield JG, Porterfield LM, Smith BA, Ventak PRx Phase I Investigators: Conversion rates of induced versus spontaneous ventricular tachycardia by a third-generation cardioverter defibrillator. Pacing Clin Electrophysiol 16:170-178, 1993
-
(1993)
Pacing Clin Electrophysiol
, vol.16
, pp. 170-178
-
-
Porterfield, J.G.1
Porterfield, L.M.2
Smith, B.A.3
-
41
-
-
0021997027
-
Clinical experience, complications and survival in 70 patients with the automatic implantable cardioverter/defibrillator
-
Echt DS, Armstrong K, Schmidt P, et al: Clinical experience, complications and survival in 70 patients with the automatic implantable cardioverter/defibrillator. Circulation 71:289-296, 1985
-
(1985)
Circulation
, vol.71
, pp. 289-296
-
-
Echt, D.S.1
Armstrong, K.2
Schmidt, P.3
-
42
-
-
0023876909
-
The automatic implantable cardioverter-defibrillator: Efficacy, complications and survival in patients with malignant ventricular arrhythmias
-
Kelly PA, Cannom DS, Garan H, et al: The automatic implantable cardioverter-defibrillator: Efficacy, complications and survival in patients with malignant ventricular arrhythmias. J Am Coll Cardiol 11:1278-1286, 1988
-
(1988)
J Am Coll Cardiol
, vol.11
, pp. 1278-1286
-
-
Kelly, P.A.1
Cannom, D.S.2
Garan, H.3
-
43
-
-
0024524506
-
Long-term outcome with the automatic implantable cardioverter-defibrillator
-
Winkle RA, Mead RH, Ruder MA, et al: Long-term outcome with the automatic implantable cardioverter-defibrillator. J Am Coll Cardiol 13:1353-1361, 1989
-
(1989)
J Am Coll Cardiol
, vol.13
, pp. 1353-1361
-
-
Winkle, R.A.1
Mead, R.H.2
Ruder, M.A.3
-
44
-
-
0024576280
-
Combined automatic implantable cardioverter-defibrillator and pacemaker systems: Implantation techniques and follow-up
-
Epstein AE, Kay GN, Plumb VJ, et al: Combined automatic implantable cardioverter-defibrillator and pacemaker systems: Implantation techniques and follow-up. J Am Coll Cardiol 13:121-131, 1989
-
(1989)
J Am Coll Cardiol
, vol.13
, pp. 121-131
-
-
Epstein, A.E.1
Kay, G.N.2
Plumb, V.J.3
-
45
-
-
0024990874
-
Clinical interactions between pacemakers and automatic implantable cardioverter-defibrillators
-
Calkins H, Brinker J, Veltri EP, et al: Clinical interactions between pacemakers and automatic implantable cardioverter-defibrillators. J Am Coll Cardiol 16:666-673, 1990
-
(1990)
J Am Coll Cardiol
, vol.16
, pp. 666-673
-
-
Calkins, H.1
Brinker, J.2
Veltri, E.P.3
-
46
-
-
0028817526
-
Implantation of transvenous nonthoracotomy cardioverter-defibrillator systems in patients with permanent endocardial pacemakers
-
Brooks R, Garan H, McGovern BA, et al: Implantation of transvenous nonthoracotomy cardioverter-defibrillator systems in patients with permanent endocardial pacemakers. Am Heart J 129:45-53, 1995
-
(1995)
Am Heart J
, vol.129
, pp. 45-53
-
-
Brooks, R.1
Garan, H.2
McGovern, B.A.3
-
47
-
-
0025884658
-
Reduction in defibrillator shocks with an implantable device combining antitachycardia pacing and shock therapy
-
Leitch JW, Gillis AM, Wyse G, et al: Reduction in defibrillator shocks with an implantable device combining antitachycardia pacing and shock therapy. J Am Coll Cardiol 18:145-151, 1991
-
(1991)
J Am Coll Cardiol
, vol.18
, pp. 145-151
-
-
Leitch, J.W.1
Gillis, A.M.2
Wyse, G.3
-
48
-
-
0026504952
-
Clinical experience with a tiered-therapy, multiprogrammable antiarrhythmia device
-
Bardy GH, Troutman C, Poole JE, et al: Clinical experience with a tiered-therapy, multiprogrammable antiarrhythmia device. Circulation 85:1689-1698, 1992
-
(1992)
Circulation
, vol.85
, pp. 1689-1698
-
-
Bardy, G.H.1
Troutman, C.2
Poole, J.E.3
-
49
-
-
0028288419
-
Interactions between drugs and devices: Experimental and clinical studies
-
Manz M, Jung W, Luderitz B: Interactions between drugs and devices: Experimental and clinical studies. Am Heart J 127:978-984, 1994
-
(1994)
Am Heart J
, vol.127
, pp. 978-984
-
-
Manz, M.1
Jung, W.2
Luderitz, B.3
-
50
-
-
0028893330
-
Results of delivered therapy of VT or VF in patients with third-generation implantable cardioverter defibrillators
-
Rabinovich R, Muratore C, Iglesias R, et al: Results of delivered therapy of VT or VF in patients with third-generation implantable cardioverter defibrillators. PACE 18:133-136, 1995
-
(1995)
PACE
, vol.18
, pp. 133-136
-
-
Rabinovich, R.1
Muratore, C.2
Iglesias, R.3
-
51
-
-
0023618377
-
Automatic implantable cardioverter defibrillator/pacemaker interaction: Loss of pacemaker capture following AICD discharge
-
Slepian M, Levine JH, Watkins L Jr, et al: Automatic implantable cardioverter defibrillator/pacemaker interaction: Loss of pacemaker capture following AICD discharge. PACE 10:1194-1197, 1987
-
(1987)
PACE
, vol.10
, pp. 1194-1197
-
-
Slepian, M.1
Levine, J.H.2
Watkins Jr., L.3
-
53
-
-
0002637901
-
Effect of cardioversion and defibrillation on implanted cardiac pacemakers
-
Barold SS (ed): Mount Kisco, NY, Futura
-
Levine PA: Effect of cardioversion and defibrillation on implanted cardiac pacemakers, in Barold SS (ed): Modern Cardiac Pacing. Mount Kisco, NY, Futura, 1985, pp 875-886
-
(1985)
Modern Cardiac Pacing
, pp. 875-886
-
-
Levine, P.A.1
-
54
-
-
0019813313
-
Pacemaker malfunction following transthoracic countershock
-
Das G, Eaton J: Pacemaker malfunction following transthoracic countershock. PACE 4:487-490, 1981
-
(1981)
PACE
, vol.4
, pp. 487-490
-
-
Das, G.1
Eaton, J.2
-
55
-
-
0024270487
-
The use and interaction of permanent pacemakers and the automatic implantable cardioverterdefibrillator
-
Cohen AI, Wish MH, Fletcher RD, et al: The use and interaction of permanent pacemakers and the automatic implantable cardioverterdefibrillator. PACE 11:704-711, 1988
-
(1988)
PACE
, vol.11
, pp. 704-711
-
-
Cohen, A.I.1
Wish, M.H.2
Fletcher, R.D.3
-
56
-
-
0018249070
-
Reprogramming of implanted pacemaker following external defibrillation
-
Barold SS, Ong LS, Scovil IJ, et al: Reprogramming of implanted pacemaker following external defibrillation. PACE 1:514-520, 1978
-
(1978)
PACE
, vol.1
, pp. 514-520
-
-
Barold, S.S.1
Ong, L.S.2
Scovil, I.J.3
-
57
-
-
0008079202
-
Risk of pacemaker damage induced by implantable defibrillator shocks
-
Ching E, Carlblom D, Wilkoff BL, et al: Risk of pacemaker damage induced by implantable defibrillator shocks. PACE 14:629, 1991
-
(1991)
PACE
, vol.14
, pp. 629
-
-
Ching, E.1
Carlblom, D.2
Wilkoff, B.L.3
-
58
-
-
0029126467
-
The proarrhythmic potential of implantable cardioverter-defibrillators
-
Pinski SL, Fahy GJ: The proarrhythmic potential of implantable cardioverter-defibrillators. Circulation 92:1651-1664, 1995
-
(1995)
Circulation
, vol.92
, pp. 1651-1664
-
-
Pinski, S.L.1
Fahy, G.J.2
-
59
-
-
0028589916
-
Safety of pacemaker implantation in patients with transvenous (nonthoracotomy) implantable cardioverter defibrillators
-
Clemo HF, Ellenbogen KA, Belz MK, et al: Safety of pacemaker implantation in patients with transvenous (nonthoracotomy) implantable cardioverter defibrillators. PACE 17:2285-2290, 1994
-
(1994)
PACE
, vol.17
, pp. 2285-2290
-
-
Clemo, H.F.1
Ellenbogen, K.A.2
Belz, M.K.3
-
60
-
-
0022598366
-
The automatic implantable cardioverterdefibrillator. Evaluating suspected inappropriate shocks
-
Chapman PD, Troup P: The automatic implantable cardioverterdefibrillator. Evaluating suspected inappropriate shocks. J Am Coll Cardiol 7:1075-1078, 1986
-
(1986)
J Am Coll Cardiol
, vol.7
, pp. 1075-1078
-
-
Chapman, P.D.1
Troup, P.2
-
61
-
-
0028077584
-
Feasibility of concomitant implantation of permanent transvenous pacemaker and defibrillator systems
-
Blanck Z, Niazi I, Axtell K, et al: Feasibility of concomitant implantation of permanent transvenous pacemaker and defibrillator systems. Am J Cardiol 74:1249-1253, 1994
-
(1994)
Am J Cardiol
, vol.74
, pp. 1249-1253
-
-
Blanck, Z.1
Niazi, I.2
Axtell, K.3
-
62
-
-
0022499298
-
Unipolar pacer artifacts induced failure of an automatic implantable cardioverter/defibrillator to detect ventricular fibrillation
-
Kim SG, Furman S, Waspe LE, et al: Unipolar pacer artifacts induced failure of an automatic implantable cardioverter/defibrillator to detect ventricular fibrillation. Am J Cardiol 57:880-881, 1986
-
(1986)
Am J Cardiol
, vol.57
, pp. 880-881
-
-
Kim, S.G.1
Furman, S.2
Waspe, L.E.3
-
63
-
-
0023863096
-
Automatic implantable defibrillator discharge resulting from routine pacemaker programming
-
Gottlieb CD, Miller JM, Rosenthal ME, et al: Automatic implantable defibrillator discharge resulting from routine pacemaker programming. PACE 11:336-338, 1988
-
(1988)
PACE
, vol.11
, pp. 336-338
-
-
Gottlieb, C.D.1
Miller, J.M.2
Rosenthal, M.E.3
-
64
-
-
0023181436
-
Automatic implantable cardioverter/defibrillotor. Inadvertent discharges during permanent pacemaker magnet tests
-
Kim SG, Furman S, Matos JA, et al: Automatic implantable cardioverter/defibrillotor. Inadvertent discharges during permanent pacemaker magnet tests. PACE 10:579-582, 1987
-
(1987)
PACE
, vol.10
, pp. 579-582
-
-
Kim, S.G.1
Furman, S.2
Matos, J.A.3
-
65
-
-
85077805960
-
-
St Paul, Minnesota, CPI, chapt 1, Description and use
-
Guidant Corportion/Cardiac Pacemakers (CPI): Ventak® Mini™ Physician's System Manual. St Paul, Minnesota, CPI, chapt 1, Description and use
-
Ventak® Mini™ Physician's System Manual
-
-
-
66
-
-
85077805960
-
-
St Paul, Minnesota, CPI, chapt 9, using the magnet
-
Guidant Corportion/Cardiac Pacemakers (CPI): Ventak® Mini™ Physician's System Manual. St Paul, Minnesota, CPI, chapt 9, using the magnet
-
Ventak® Mini™ Physician's System Manual
-
-
-
68
-
-
85077805600
-
-
Angleton, Texas, Sulzer Intermedics Inc, chapter 5
-
Sulzer Intermedics, Inc: Res-Q Micron Physician's Manual, Angleton, Texas, Sulzer Intermedics Inc, chapter 5
-
Res-Q Micron Physician's Manual
-
-
|