메뉴 건너뛰기




Volumn 14, Issue 1, 1999, Pages 209-213

A comparison of a new transtelephonic portable spirometer with a laboratory spirometer

Author keywords

Asthma; Flow volume curve; Home monitoring; Spirophone; Telemedicine

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FEMALE; FORCED EXPIRATORY VOLUME; HUMAN; LUNG FLOW VOLUME CURVE; MALE; PEAK EXPIRATORY FLOW; PRIORITY JOURNAL; SPIROMETER; SPIROMETRY; VALIDATION PROCESS; VITAL CAPACITY;

EID: 0032826412     PISSN: 09031936     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1399-3003.1999.14a35.x     Document Type: Article
Times cited : (10)

References (29)
  • 1
    • 8244223179 scopus 로고    scopus 로고
    • Influence on asthma morbidity of asthma education programs based on self-management plans following treatment optimization
    • Cote J, Cartier A, Robichaud P, et al. Influence on asthma morbidity of asthma education programs based on self-management plans following treatment optimization. Am J Respir Crit Care Med 1997; 155: 1509-1514.
    • (1997) Am J Respir Crit Care Med , vol.155 , pp. 1509-1514
    • Cote, J.1    Cartier, A.2    Robichaud, P.3
  • 3
    • 0025323077 scopus 로고
    • Long-term management of reversible obstructive airways disease in adults
    • Lurie A, Vlastos FD, Dusser DJ, Strauch G, Marsac J. Long-term management of reversible obstructive airways disease in adults. Lung 1990; 168: Suppl. 154-167.
    • (1990) Lung , vol.168 , Issue.SUPPL. , pp. 154-167
    • Lurie, A.1    Vlastos, F.D.2    Dusser, D.J.3    Strauch, G.4    Marsac, J.5
  • 4
    • 0029090616 scopus 로고
    • Standardization of spirometry, 1994 update
    • American Thoracic Society. Standardization of spirometry, 1994 update. Am J Respir Crit Care Med 1995; 152: 1107-1136.
    • (1995) Am J Respir Crit Care Med , vol.152 , pp. 1107-1136
  • 5
    • 0023442646 scopus 로고
    • Standardization of spirometry, 1987 upadate
    • American Thoracic Society. Standardization of Spirometry, 1987 Upadate. Am Rev Respir Dis 1987; 136: 1285-1298.
    • (1987) Am Rev Respir Dis , vol.136 , pp. 1285-1298
  • 6
    • 0029876214 scopus 로고    scopus 로고
    • Assessment of a new transtelephonic portable spirometer
    • Abboud S, Bruderman I. Assessment of a new transtelephonic portable spirometer. Thorax 1996; 51: 407-410.
    • (1996) Thorax , vol.51 , pp. 407-410
    • Abboud, S.1    Bruderman, I.2
  • 7
    • 0030752394 scopus 로고    scopus 로고
    • Telespirometry: A novel system for home monitoring of asthmatic patients
    • Bruderman I, Abboud S. Telespirometry: a novel system for home monitoring of asthmatic patients. Telemed J 1997; 3: 127-133.
    • (1997) Telemed J , vol.3 , pp. 127-133
    • Bruderman, I.1    Abboud, S.2
  • 8
    • 25744452227 scopus 로고    scopus 로고
    • The accuracy of the spirophone, a novel transtelephonic portable spirometer
    • Bolliger CT, Gonon M, Abboud S, Bruderman I, Perruchoud AP. The accuracy of the spirophone, a novel transtelephonic portable spirometer. Eur Respir J 1996; 9: Suppl. 23, 469S.
    • (1996) Eur Respir J , vol.9 , Issue.SUPPL. 23
    • Bolliger, C.T.1    Gonon, M.2    Abboud, S.3    Bruderman, I.4    Perruchoud, A.P.5
  • 9
    • 0015538734 scopus 로고
    • Heated fleisch pneumotachometer: A calibration procedure
    • Turney SZ, Blumenfeld W. Heated Fleisch pneumotachometer: a calibration procedure. J Appl Physiol 1973; 34: 117-121.
    • (1973) J Appl Physiol , vol.34 , pp. 117-121
    • Turney, S.Z.1    Blumenfeld, W.2
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 8: 307-310.
    • (1986) Lancet , vol.8 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 11
    • 0027173650 scopus 로고
    • Evaluation of a new ambulatory spirometer for measuring forced expiratory volume in one second and peak expiratory flow rate
    • Johns DP, Abramson M, Bowes G. Evaluation of a new ambulatory spirometer for measuring forced expiratory volume in one second and peak expiratory flow rate. Am Rev Respir Dis 1993; 147: 1245-1250.
    • (1993) Am Rev Respir Dis , vol.147 , pp. 1245-1250
    • Johns, D.P.1    Abramson, M.2    Bowes, G.3
  • 12
  • 13
    • 0020356666 scopus 로고
    • An education program that improves the psychomotor skills needed for metaproterenol inhaler use
    • O'Bey KA, Jim LK, Gee JP, Cowen ME, Quigley AE. An education program that improves the psychomotor skills needed for metaproterenol inhaler use. Drug Intell Clin Pharm 1982; 16: 945-948.
    • (1982) Drug Intell Clin Pharm , vol.16 , pp. 945-948
    • O'Bey, K.A.1    Jim, L.K.2    Gee, J.P.3    Cowen, M.E.4    Quigley, A.E.5
  • 14
    • 0023406837 scopus 로고
    • The effect of a structured education program on knowledge and psychomotor skills of patients using beclomethasone dipropionate aerosol for steroid dependent asthma
    • Heringa P, Lawson L, Reda D. The effect of a structured education program on knowledge and psychomotor skills of patients using beclomethasone dipropionate aerosol for steroid dependent asthma. Health Educ Q 1987; 14: 309-317.
    • (1987) Health Educ Q , vol.14 , pp. 309-317
    • Heringa, P.1    Lawson, L.2    Reda, D.3
  • 15
    • 0024327608 scopus 로고
    • Asthma self-management education. Research and implications for clinical practice
    • Clark NM. Asthma self-management education. Research and implications for clinical practice. Chest 1989; 95: 1110-1113.
    • (1989) Chest , vol.95 , pp. 1110-1113
    • Clark, N.M.1
  • 17
    • 0028855145 scopus 로고
    • Asthma self-management education program by home monitoring of peak expiratory flow
    • Ignacio-Garcia JM, Gonzalez-Santos P. Asthma self-management education program by home monitoring of peak expiratory flow. Am J Respir Crit Care Med 1995; 151: 353-359.
    • (1995) Am J Respir Crit Care Med , vol.151 , pp. 353-359
    • Ignacio-Garcia, J.M.1    Gonzalez-Santos, P.2
  • 18
    • 0022178390 scopus 로고
    • Improving the ability of peak expiratory flow rates to predict asthma
    • Harm DL, Kotses H, Crer TL. Improving the ability of peak expiratory flow rates to predict asthma. J Allergy Clin Immunol 1985; 76: 688-694.
    • (1985) J Allergy Clin Immunol , vol.76 , pp. 688-694
    • Harm, D.L.1    Kotses, H.2    Crer, T.L.3
  • 19
    • 0023801176 scopus 로고
    • Effect of peak flow information on patterns of self-care in adults
    • Janson-Bjeklie S, Shnell S. Effect of peak flow information on patterns of self-care in adults. Heart Lung 1988; 17: 543-549.
    • (1988) Heart Lung , vol.17 , pp. 543-549
    • Janson-Bjeklie, S.1    Shnell, S.2
  • 20
    • 0025681709 scopus 로고
    • Evaluation of peak-flow and symptoms only self-management plans for control of asthma in general practice
    • Charlton I, Charlton G, Broomfield J, Mullee MA. Evaluation of peak-flow and symptoms only self-management plans for control of asthma in general practice. BMJ 1990; 301: 1355-1359.
    • (1990) BMJ , vol.301 , pp. 1355-1359
    • Charlton, I.1    Charlton, G.2    Broomfield, J.3    Mullee, M.A.4
  • 21
    • 0024543839 scopus 로고
    • A self management plan in the treatment of adult asthma
    • Beasley R, Cushley M, Holgate ST. A self management plan in the treatment of adult asthma. Thorax 1989; 44: 200-204.
    • (1989) Thorax , vol.44 , pp. 200-204
    • Beasley, R.1    Cushley, M.2    Holgate, S.T.3
  • 22
    • 0029897560 scopus 로고    scopus 로고
    • Use of peak flow-based self-management plans by adult asthmatic patients
    • Fishwick D, Beasley R. Use of peak flow-based self-management plans by adult asthmatic patients. Eur Respir J 1996; 9: 861-865.
    • (1996) Eur Respir J , vol.9 , pp. 861-865
    • Fishwick, D.1    Beasley, R.2
  • 23
    • 0029111883 scopus 로고
    • Peak expiratory flow monitoring is not a reliable method for establishing the diagnosis of occupational asthma
    • Quirce S, Contreras G, Dybuncio A, Chan-Yeung M. Peak expiratory flow monitoring is not a reliable method for establishing the diagnosis of occupational asthma. Am J Respir Crit Care Med 1995; 152: 1100-1102.
    • (1995) Am J Respir Crit Care Med , vol.152 , pp. 1100-1102
    • Quirce, S.1    Contreras, G.2    Dybuncio, A.3    Chan-Yeung, M.4
  • 24
    • 0030003235 scopus 로고    scopus 로고
    • Compliance with and accuracy of daily self-assessment of peak expiratory flows (PEF) in asthmatic subjects over a three month period
    • Verschelden P, Cartier A, L'Archeveque J, Trudeau C, Malo J-L. Compliance with and accuracy of daily self-assessment of peak expiratory flows (PEF) in asthmatic subjects over a three month period. Eur Respir J 1996; 9: 880-885.
    • (1996) Eur Respir J , vol.9 , pp. 880-885
    • Verschelden, P.1    Cartier, A.2    L'Archeveque, J.3    Trudeau, C.4    Malo, J.-L.5
  • 25
    • 0029941456 scopus 로고    scopus 로고
    • Home recording of PEF in young asthmatics: Does it contribute to management?
    • Uwyyed K, Springer C, Avital A, Bar-Yishay E, Godfrey S. Home recording of PEF in young asthmatics: does it contribute to management? Eur Respir J 1996; 9: 872-879.
    • (1996) Eur Respir J , vol.9 , pp. 872-879
    • Uwyyed, K.1    Springer, C.2    Avital, A.3    Bar-Yishay, E.4    Godfrey, S.5
  • 26
    • 0027300606 scopus 로고
    • Daily home spirometry facilitates early detection of rejection in single lung transplant recipients with emphysema
    • Bjortuft O, Johansen B, Boe J, Foerster A, Holter E, Geiran O. Daily home spirometry facilitates early detection of rejection in single lung transplant recipients with emphysema. Eur Respir J 1993; 6: 705-708.
    • (1993) Eur Respir J , vol.6 , pp. 705-708
    • Bjortuft, O.1    Johansen, B.2    Boe, J.3    Foerster, A.4    Holter, E.5    Geiran, O.6
  • 27
    • 0025064237 scopus 로고
    • The use of home spirometry in detecting acute lung rejection and infection following heart-lung transplantation
    • Otulana BA, Higenbottam T, Ferrari L, Scott J, Igboaka G, Wallwork J. The use of home spirometry in detecting acute lung rejection and infection following heart-lung transplantation. Chest 1990; 97: 353-357.
    • (1990) Chest , vol.97 , pp. 353-357
    • Otulana, B.A.1    Higenbottam, T.2    Ferrari, L.3    Scott, J.4    Igboaka, G.5    Wallwork, J.6
  • 28
    • 0027485583 scopus 로고
    • Reliability and validity of spirometry measurements in a paperless home monitoring diary program for lung transplantation
    • Finkenlstein SM, Lindgren B, Prasad B, et al. Reliability and validity of spirometry measurements in a paperless home monitoring diary program for lung transplantation. Heart Lung 1993; 22: 523-533.
    • (1993) Heart Lung , vol.22 , pp. 523-533
    • Finkenlstein, S.M.1    Lindgren, B.2    Prasad, B.3
  • 29
    • 0004519471 scopus 로고    scopus 로고
    • Telemedicine in the postinterventional surveillance of patients with central airway obstruction
    • Bolliger CT, Wyser C, Perruchoud AP. Telemedicine in the postinterventional surveillance of patients with central airway obstruction. Eur Respir J 1998; 12: Suppl. 28, 266S.
    • (1998) Eur Respir J , vol.12 , Issue.SUPPL. 28
    • Bolliger, C.T.1    Wyser, C.2    Perruchoud, A.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.