메뉴 건너뛰기




Volumn 9, Issue 5, 1996, Pages 880-885

Compliance with and accuracy of daily self-assessment of peak expiratory flows (PEF) in asthmatic subjects over a three month period

Author keywords

Asthma; peak expiratory flow rate; subject compliance

Indexed keywords

ADULT; ARTICLE; ASTHMA; CLINICAL ARTICLE; DIAGNOSTIC ACCURACY; HUMAN; LUNG COMPLIANCE; PEAK EXPIRATORY FLOW; PRIORITY JOURNAL; SELF EVALUATION; SPIROMETRY;

EID: 0030003235     PISSN: 09031936     EISSN: None     Source Type: Journal    
DOI: 10.1183/09031936.96.09050880     Document Type: Article
Times cited : (110)

References (23)
  • 1
    • 0000225183 scopus 로고
    • Chronic bronchitis, asthma, and pulmonary emphysema. Statement by the committee on diagnostic standards for nontuberculous respiratory diseases
    • American Thoracic Society. Chronic bronchitis, asthma, and pulmonary emphysema. Statement by the committee on diagnostic standards for nontuberculous respiratory diseases. Am Rev Respir Dis 1962; 85: 762-768.
    • (1962) Am Rev Respir Dis , vol.85 , pp. 762-768
  • 2
    • 0018921338 scopus 로고
    • Evaluation of the severity of asthma: Patients versus physicians
    • Shim CS, Williams MH. Evaluation of the severity of asthma: patients versus physicians. Am J Med 1980; 68: 11-13.
    • (1980) Am J Med , vol.68 , pp. 11-13
    • Shim, C.S.1    Williams, M.H.2
  • 5
    • 0028260847 scopus 로고
    • Perception scoring of induced bronchoconstriction as an index of awareness of asthma symptoms
    • Boulet LP, Leblanc P, Turcotte H. Perception scoring of induced bronchoconstriction as an index of awareness of asthma symptoms. Chest 1994; 105: 1430-1433.
    • (1994) Chest , vol.105 , pp. 1430-1433
    • Boulet, L.P.1    Leblanc, P.2    Turcotte, H.3
  • 8
    • 0028884914 scopus 로고
    • Do subjects investigated for occupational asthma through serial PEF measurements falsify their results?
    • Malo JL, Trudeau C, Ghezzo H, L'Archevêque J, Cartier A. Do subjects investigated for occupational asthma through serial PEF measurements falsify their results? J Allergy Clin Immunol 1995; 96: 601-507.
    • (1995) J Allergy Clin Immunol , vol.96 , pp. 601-1507
    • Malo, J.L.1    Trudeau, C.2    Ghezzo, H.3    L'Archevêque, J.4    Cartier, A.5
  • 9
    • 0029111883 scopus 로고
    • Peak expiratory flow monitoring is not a reliable method for establishing the diagnosis of occupational asthma
    • Quirce S, Contreras G, DyBuncio A, Chan-Yeung M. Peak expiratory flow monitoring is not a reliable method for establishing the diagnosis of occupational asthma. Am J Respir Crit Care Med 1995; 152: 1100-1102.
    • (1995) Am J Respir Crit Care Med , vol.152 , pp. 1100-1102
    • Quirce, S.1    Contreras, G.2    DyBuncio, A.3    Chan-Yeung, M.4
  • 10
    • 0029090616 scopus 로고
    • Standardization of spirometry
    • American Thoracic Society. Standardization of spirometry. Am J Respir Care Med 1995; 152: 1107-1136.
    • (1995) Am J Respir Care Med , vol.152 , pp. 1107-1136
  • 11
    • 0020585150 scopus 로고
    • Changes in the normal maximal expiratory flow-volume curve with growth an aging
    • Knudson RJ, Lebowitz MD, Holberg CJ, Burrows B. Changes in the normal maximal expiratory flow-volume curve with growth an aging. Am Rev Respir Dis 1983; 127: 725-734.
    • (1983) Am Rev Respir Dis , vol.127 , pp. 725-734
    • Knudson, R.J.1    Lebowitz, M.D.2    Holberg, C.J.3    Burrows, B.4
  • 12
    • 0018757078 scopus 로고
    • Peak flow rate records in the diagnosis of occupational asthma due to isocyanates
    • Burge PS, O'Brien IM, Harries MG. Peak flow rate records in the diagnosis of occupational asthma due to isocyanates. Thorax 1979; 34: 317-323.
    • (1979) Thorax , vol.34 , pp. 317-323
    • Burge, P.S.1    O'Brien, I.M.2    Harries, M.G.3
  • 13
    • 0017564617 scopus 로고
    • Diagnosing potential noncompliance
    • Mushlin AI, Appel FA. Diagnosing potential noncompliance. Arch Intern Med 1977; 137: 318-321.
    • (1977) Arch Intern Med , vol.137 , pp. 318-321
    • Mushlin, A.I.1    Appel, F.A.2
  • 14
    • 0028058215 scopus 로고
    • Measuring adherence to asthma medication regimens
    • Rand CS, Wise RA. Measuring adherence to asthma medication regimens. Am J Respir Crit Care Med 1995; 149: 569-576.
    • (1995) Am J Respir Crit Care Med , vol.149 , pp. 569-576
    • Rand, C.S.1    Wise, R.A.2
  • 15
    • 0003289507 scopus 로고
    • Adherence to health care regimens
    • Prokop CK, Bradley LA, eds. New York, Academic Press Inc.
    • Masur FT. Adherence to health care regimens. In: Prokop CK, Bradley LA, eds. Medical Psychology: Contributions to Behavioural Medicine. New York, Academic Press Inc., 1981; pp. 441-470.
    • (1981) Medical Psychology: Contributions to Behavioural Medicine , pp. 441-470
    • Masur, F.T.1
  • 16
    • 0022639356 scopus 로고
    • Compliance of patients with asthma with an experimental aerosolized medication: Implications for controlled clinical trials
    • Spector SL, Kinsman R, Mawhinney H, et al. Compliance of patients with asthma with an experimental aerosolized medication: implications for controlled clinical trials. J Allergy Clin Immunol 1986; 77: 65-70.
    • (1986) J Allergy Clin Immunol , vol.77 , pp. 65-70
    • Spector, S.L.1    Kinsman, R.2    Mawhinney, H.3
  • 17
    • 0002450733 scopus 로고
    • Methods of assessing and improving patient compliance in clinical trials
    • Cramer JA, Spilker B, eds. New York, Raven Press Ltd
    • Spilker B. Methods of assessing and improving patient compliance in clinical trials. In: Cramer JA, Spilker B, eds. Patient Compliance in Medical Practice and Clinical Trials. New York, Raven Press Ltd, 1991; pp. 37-56.
    • (1991) Patient Compliance in Medical Practice and Clinical Trials , pp. 37-56
    • Spilker, B.1
  • 18
    • 0026543585 scopus 로고
    • A comparison of the effects of b.i.d. and q.i.d. dosing on compliance with inhaled flunisolide
    • Mann M, Eliasson O, Patel K, ZuWallack RL. A comparison of the effects of b.i.d. and q.i.d. dosing on compliance with inhaled flunisolide. Chest 1992; 101: 496-499.
    • (1992) Chest , vol.101 , pp. 496-499
    • Mann, M.1    Eliasson, O.2    Patel, K.3    Zuwallack, R.L.4
  • 19
    • 0028274731 scopus 로고
    • Patient compliance with inhaled medication: Does combining beta-agonists with corticosteroids improve compliance?
    • Bosley CM, Parry DT, Cochcrane GM. Patient compliance with inhaled medication: does combining beta-agonists with corticosteroids improve compliance? Eur Respir J 1994; 7: 504-509.
    • (1994) Eur Respir J , vol.7 , pp. 504-509
    • Bosley, C.M.1    Parry, D.T.2    Cochcrane, G.M.3
  • 21
    • 0029121661 scopus 로고
    • Peak flow based asthma self-management: A randomised controlled study in general practice
    • Jones KP, Mulleee MA, Middleton M, Chapman E, Holgate ST and the British Thoracic Society Research Committee. Peak flow based asthma self-management: a randomised controlled study in general practice. Thorax 1995; 50: 851-857.
    • (1995) Thorax , vol.50 , pp. 851-857
    • Jones, K.P.1    Mulleee, M.A.2    Middleton, M.3    Chapman, E.4    Holgate, S.T.5
  • 22
    • 0027169119 scopus 로고
    • Accuracy of perception of severity of asthma: Patients treated in general practice
    • Kendrick AH, Higgs CMB, Whitfield MJ, Lazlo G. Accuracy of perception of severity of asthma: patients treated in general practice. BMJ 1993; 307: 422-424.
    • (1993) BMJ , vol.307 , pp. 422-424
    • Kendrick, A.H.1    Higgs, C.M.B.2    Whitfield, M.J.3    Lazlo, G.4
  • 23
    • 0028280428 scopus 로고
    • Chemosensitivity and perception of dyspnoea in patients with a history of near-fatal asthma
    • Kikuchi Y, Okabe S, Tamura G, et al. Chemosensitivity and perception of dyspnoea in patients with a history of near-fatal asthma. N Engl J Med 1994; 330: 1329-1334.
    • (1994) N Engl J Med , vol.330 , pp. 1329-1334
    • Kikuchi, Y.1    Okabe, S.2    Tamura, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.