메뉴 건너뛰기




Volumn 52, Issue 3, 1999, Pages 152-159

Hemodiafiltration - A new treatment option for hyperphosphatemia in hemodialysis patients

Author keywords

2 microglobulin removal; Creatinine; Hemodiafiltration; Hyperphosphatemia; Phosphate elimination urea

Indexed keywords

BETA 2 MICROGLOBULIN; CREATININE; PHOSPHATE; POLYSULFONE; UREA;

EID: 0032822363     PISSN: 03010430     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (94)

References (22)
  • 2
    • 0023153802 scopus 로고
    • 2-microglobulin concentration after cuprophane haemodialysis
    • 2-microglobulin concentration after cuprophane haemodialysis. Lancet 1: 628-629
    • (1987) Lancet , vol.1 , pp. 628-629
    • Bergström, J.1    Wehle, B.2
  • 3
    • 0023218469 scopus 로고
    • Behavior of beta-2 microglobulin in patients with chronic renal failure undergoing hemodialysis, hemodiafiltration and CAPD
    • Blumberg A, Buergi W 1987 Behavior of beta-2 microglobulin in patients with chronic renal failure undergoing hemodialysis, hemodiafiltration and CAPD. Clin Nephrol 27: 245-249
    • (1987) Clin Nephrol , vol.27 , pp. 245-249
    • Blumberg, A.1    Buergi, W.2
  • 4
    • 0028319663 scopus 로고
    • Hemodiafiltration with on-line production of substitution fluid: Long term safety and quantitative assessment of efficacy
    • Maeda K, Shinzato T (eds) Effective hemodiafiltration: new methods.
    • Canaud B, Flavier JL, Argiles A, Stec F, Nguyen QV, Baulox C, Garred LJ, Mion C 1994 Hemodiafiltration with on-line production of substitution fluid: long term safety and quantitative assessment of efficacy. In: Maeda K, Shinzato T (eds) Effective hemodiafiltration: new methods. Contrib Nephrol Karger Basel 108: 12-22
    • (1994) Contrib Nephrol Karger Basel , vol.108 , pp. 12-22
    • Canaud, B.1    Flavier, J.L.2    Argiles, A.3    Stec, F.4    Nguyen, Q.V.5    Baulox, C.6    Garred, L.J.7    Mion, C.8
  • 6
    • 0029853381 scopus 로고    scopus 로고
    • Fractional direct dialysis quantification: A new approach for prescription and monitoring hemodialysis therapy
    • Charytan C, Gupta B, Meindel N, Spinowitz B 1996 Fractional direct dialysis quantification: a new approach for prescription and monitoring hemodialysis therapy. Kidney Int 50: 1845-1849
    • (1996) Kidney Int , vol.50 , pp. 1845-1849
    • Charytan, C.1    Gupta, B.2    Meindel, N.3    Spinowitz, B.4
  • 7
    • 0028020794 scopus 로고
    • Membrane adsorption of beta 2-microglobulin: Equilibrium and kinetic characterization
    • Clark, WR, Macias WL, Molitoris BA, Wang NH 1994 Membrane adsorption of beta 2-microglobulin: equilibrium and kinetic characterization. Kidney Int 46: 1140-1146
    • (1994) Kidney Int , vol.46 , pp. 1140-1146
    • Clark, W.R.1    Macias, W.L.2    Molitoris, B.A.3    Wang, N.H.4
  • 8
    • 0027690435 scopus 로고
    • Phosphate kinetics during high-flux hemodialysis
    • DeSol CA, Umans J G 1993 Phosphate kinetics during high-flux hemodialysis. J Am Soc Nephrol 4: 1214-1218
    • (1993) J Am Soc Nephrol , vol.4 , pp. 1214-1218
    • Desol, C.A.1    Umans, J.G.2
  • 9
    • 0028209208 scopus 로고
    • Un diviseur de flux qui permet, en cours d'hémodialyse, le receuil continu d'un échantillon représentatif du dialysat
    • Fellay G, Gabriel JP 1994 Un diviseur de flux qui permet, en cours d'hémodialyse, le receuil continu d'un échantillon représentatif du dialysat. Néphrologie 15:33-35
    • (1994) Néphrologie , vol.15 , pp. 33-35
    • Fellay, G.1    Gabriel, J.P.2
  • 10
    • 0024358898 scopus 로고
    • Highflux synthetic versus cellulosic membranes for β2-microglobulin removal during haemodialysis, haemodiafiltration and haemofiltration
    • Floege J, Granolleras C, Deschodt DT et al. 1989 Highflux synthetic versus cellulosic membranes for β2-microglobulin removal during haemodialysis, haemodiafiltration and haemofiltration. Nephrol Dial Transplant 4: 653-657
    • (1989) Nephrol Dial Transplant , vol.4 , pp. 653-657
    • Floege, J.1    Granolleras, C.2    Deschodt, D.T.3
  • 11
    • 0024338031 scopus 로고
    • Adsorption of β2-microglobulin on dialysis membranes: Comparison of different dialyzers and effects of reuse procedures
    • Goldman M, Lagmiche M, Dhaene M, Amraoui Z, Thayse C and Vanherweghem JL 1989 Adsorption of β2-microglobulin on dialysis membranes: comparison of different dialyzers and effects of reuse procedures. Int J Artif Organs 12:373-378
    • (1989) Int J Artif Organs , vol.12 , pp. 373-378
    • Goldman, M.1    Lagmiche, M.2    Dhaene, M.3    Amraoui, Z.4    Thayse, C.5    Vanherweghem, J.L.6
  • 12
    • 0025836404 scopus 로고
    • Phosphate kinetics in dialysis patients
    • Haas T, Hillion D, Dongradi G 1991 Phosphate kinetics in dialysis patients. Nephrol Dial Transplant 6 (Suppl 2): 108-113
    • (1991) Nephrol Dial Transplant , vol.6 , Issue.SUPPL. 2 , pp. 108-113
    • Haas, T.1    Hillion, D.2    Dongradi, G.3
  • 13
    • 0344143234 scopus 로고
    • Phosphate balance and metabolism
    • Jacobson HR, Striker GE, Klahr S (eds) Mosby Year Book, St. Louis, Missouri, USA, pp
    • Hruska KA, Kovach KL 1995 Phosphate balance and metabolism. In: Jacobson HR, Striker GE, Klahr S (eds) The Principles and Practice of Nephrology. Mosby Year Book, St. Louis, Missouri, USA, pp 986-992
    • (1995) The Principles and Practice of Nephrology , pp. 986-992
    • Hruska, K.A.1    Kovach, K.L.2
  • 14
    • 0026521445 scopus 로고
    • Comparison of hemodialysis and hemodiafiltration: A long term longitudinal study
    • Kerr PB, Argiles A, Flavier JL, Canaud B, Mion CM 1992 Comparison of hemodialysis and hemodiafiltration: A long term longitudinal study. Kidney Int 41: 1035-1040
    • (1992) Kidney Int , vol.41 , pp. 1035-1040
    • Kerr, P.B.1    Argiles, A.2    Flavier, J.L.3    Canaud, B.4    Mion, C.M.5
  • 15
    • 0017801107 scopus 로고
    • Simultaneous hemofiltration/hemodialysis: An effective alternative to hemofiltration and conventional hemodialysis in the treatment of uremic patients
    • Leber HW, Wizemann V, Goubeaud G, Rawer P, Schuetterle G 1978 Simultaneous hemofiltration/hemodialysis: an effective alternative to hemofiltration and conventional hemodialysis in the treatment of uremic patients. Clin Nephrol 9: 115-121
    • (1978) Clin Nephrol , vol.9 , pp. 115-121
    • Leber, H.W.1    Wizemann, V.2    Goubeaud, G.3    Rawer, P.4    Schuetterle, G.5
  • 17
    • 0028187433 scopus 로고
    • Importance of convection in artificial kidney treatment
    • Maeda K, Shinzato (eds) Effective hemodiafiltration: new methods.
    • Ofshun NJ, Zydney AL 1994 Importance of convection in artificial kidney treatment. In: Maeda K, Shinzato (eds) Effective hemodiafiltration: new methods. Contrib Nephrol Karger Basel 108: 53-70
    • (1994) Contrib Nephrol Karger Basel , vol.108 , pp. 53-70
    • Ofshun, N.J.1    Zydney, A.L.2
  • 18
    • 0345436819 scopus 로고    scopus 로고
    • Theoretische grundlagen der dialysebehandlung. Phosphatelimination
    • Schoenweiss G (ed) Abakiss, Bad Kissingen
    • Schoenweiss G 1996 Theoretische Grundlagen der Dialysebehandlung. Phosphatelimination. In: Schoenweiss G (ed) Dialysefibel. Abakiss, Bad Kissingen, pp 164
    • (1996) Dialysefibel , pp. 164
    • Schoenweiss, G.1
  • 19
    • 1842290968 scopus 로고    scopus 로고
    • Kinetics of phosphorus during hemodialysis and the calculation of its effective dialysis clearance
    • Schueck O, Kaslikova J 1997 Kinetics of phosphorus during hemodialysis and the calculation of its effective dialysis clearance. Clin Nephrol 47: 379-383
    • (1997) Clin Nephrol , vol.47 , pp. 379-383
    • Schueck, O.1    Kaslikova, J.2
  • 21
    • 0028289834 scopus 로고
    • Influence of dialyser clearance measurement accuracy on haemodialysis prescription based on Kt/V
    • Zehnder C, Blumberg A 1994 Influence of dialyser clearance measurement accuracy on haemodialysis prescription based on Kt/V. Nephrol Dial Transplant 9: 753-757
    • (1994) Nephrol Dial Transplant , vol.9 , pp. 753-757
    • Zehnder, C.1    Blumberg, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.