메뉴 건너뛰기




Volumn 8, Issue 2, 1999, Pages 121-128

Comparison of in vivo 1H MRS of human brain tumours with 1H HR-MAS spectroscopy of intact biopsy samples in vitro

Author keywords

1H NMR spectroscopy; Biopsies; Magic angle spinning; Tumours

Indexed keywords

ARTICLE; BRAIN BIOPSY; BRAIN TUMOR; CLINICAL ARTICLE; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; HUMAN; HUMAN TISSUE; IMAGE ANALYSIS; IN VITRO STUDY; IN VIVO STUDY; INTERMETHOD COMPARISON; PRIORITY JOURNAL; PROTON NUCLEAR MAGNETIC RESONANCE; SPECTROSCOPY; ASTROCYTOMA; BIOPSY; CHEMISTRY; COMPARATIVE STUDY; GLIOBLASTOMA; MENINGIOMA; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY;

EID: 0032775344     PISSN: 13528661     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1352-8661(99)00020-4     Document Type: Article
Times cited : (90)

References (21)
  • 7
    • 0030884710 scopus 로고    scopus 로고
    • Gradient, high-resolution, magic-angle spinning nuclear magnetic resonance spectroscopy of human adipocyte tissue
    • Mills K.K., Maas W.E., Cory D.G., Singer S. Gradient, high-resolution, magic-angle spinning nuclear magnetic resonance spectroscopy of human adipocyte tissue. Magn. Reson. Med. 38:1997;399-403.
    • (1997) Magn. Reson. Med. , vol.38 , pp. 399-403
    • Mills, K.K.1    Maas, W.E.2    Cory, D.G.3    Singer, S.4
  • 9
    • 2642686624 scopus 로고    scopus 로고
    • Correlation of high-resolution magic angle spinning proton magnetic resonance spectroscopy with histopathology of intact human brain tumour specimens
    • Cheng L., Chang I., Louis D., Gonzalez R. Correlation of high-resolution magic angle spinning proton magnetic resonance spectroscopy with histopathology of intact human brain tumour specimens. Cancer. Res. 58:1998;1825-1832.
    • (1998) Cancer. Res. , vol.58 , pp. 1825-1832
    • Cheng, L.1    Chang, I.2    Louis, D.3    Gonzalez, R.4
  • 12
    • 0023860494 scopus 로고
    • Accurate quantitation of in vivo 31P NMR signals using the variable projection method and prior knowledge
    • Van den Veen J.W.C., de Beer R., Luyten P.R., van Ormondt D. Accurate quantitation of in vivo 31P NMR signals using the variable projection method and prior knowledge. Magn. Reson. Med. 6:1988;92-98.
    • (1988) Magn. Reson. Med. , vol.6 , pp. 92-98
    • Van Den Veen, J.W.C.1    De Beer, R.2    Luyten, P.R.3    Van Ormondt, D.4
  • 13
    • 0028008409 scopus 로고
    • In vivo, ex vivo, and in-vitro one- and two- dimensional nuclear magnetic resonance spectroscopy of an intracerebral glioma in rat brain: Assignment of resonances
    • Rémy C., Arús C., Ziegler A., Sam Lai E., Moreno A., Le Fur Y., Décorps M. In vivo, ex vivo, and in-vitro one- and two- dimensional nuclear magnetic resonance spectroscopy of an intracerebral glioma in rat brain: assignment of resonances. J. Neurochem. 62(1):1994;166-179.
    • (1994) J. Neurochem. , vol.62 , Issue.1 , pp. 166-179
    • Rémy, C.1    Arús, C.2    Ziegler, A.3    Sam Lai, E.4    Moreno, A.5    Le Fur, Y.6    Décorps, M.7
  • 14
    • 0030741163 scopus 로고    scopus 로고
    • Absolute concentrations of metabolites in human brain tumours using in vitro proton magnetic resonance spectroscopy
    • Kinoshita Y., Yokota A. Absolute concentrations of metabolites in human brain tumours using in vitro proton magnetic resonance spectroscopy. NMR. Biomed. 10(1):1997;2-12.
    • (1997) NMR. Biomed. , vol.10 , Issue.1 , pp. 2-12
    • Kinoshita, Y.1    Yokota, A.2
  • 15
    • 0029269288 scopus 로고
    • 13C NMR spectroscopy of human blood plasma
    • 13C NMR spectroscopy of human blood plasma. Anal. Chem. 67(5):1995;793-811.
    • (1995) Anal. Chem. , vol.67 , Issue.5 , pp. 793-811
    • Nicholson, J.1    Foxall, P.2
  • 16
    • 0028426935 scopus 로고
    • 1H MRS of high grade astrocytomas: Mobile lipid accumulation in necrotic tissue
    • 1H MRS of high grade astrocytomas: mobile lipid accumulation in necrotic tissue. NMR Biomed. 7:1994;149-155.
    • (1994) NMR Biomed. , vol.7 , pp. 149-155
    • Kuesel, A.1    Sutherland, G.2    Halliday, W.3    Smith, I.4
  • 17
    • 0031866964 scopus 로고    scopus 로고
    • The effect of sample freezing on proton magic-angle spinning NMR spectra of biological tissue
    • Middleton D.A., Bradley D.P., Conner S.C., Mullins P.G., Reid D.G. The effect of sample freezing on proton magic-angle spinning NMR spectra of biological tissue. Magn. Reson. Med. 40(1):1998;166-169.
    • (1998) Magn. Reson. Med. , vol.40 , Issue.1 , pp. 166-169
    • Middleton, D.A.1    Bradley, D.P.2    Conner, S.C.3    Mullins, P.G.4    Reid, D.G.5
  • 20
    • 0029302609 scopus 로고
    • 3D localised 2D spectroscopy on an MRI scanner
    • Ryner L.N., Sorenson J.A., Thomas M.A. 3D localised 2D spectroscopy on an MRI scanner. J. Magn. Reson. B107:1995;126-137.
    • (1995) J. Magn. Reson. , vol.107 , pp. 126-137
    • Ryner, L.N.1    Sorenson, J.A.2    Thomas, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.