메뉴 건너뛰기




Volumn 44, Issue 11, 1999, Pages 2789-2801

Dosimetry techniques for narrow proton beam radiosurgery

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; DOSIMETRY; FILM; MEASUREMENT; PRIORITY JOURNAL; PROTON RADIATION; RADIATION DETECTION; RADIATION DETECTOR; RADIATION DOSE DISTRIBUTION; RADIOSURGERY; STEREOTAXIC SURGERY; TECHNIQUE;

EID: 0032755939     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/44/11/308     Document Type: Article
Times cited : (54)

References (26)
  • 1
    • 0000277337 scopus 로고
    • Instrumentation for treatment of cancer using proton and light-ion beams
    • Chu W T, Ludewigt B A and Renner T R 1993 Instrumentation for treatment of cancer using proton and light-ion beams Rev. Sci. Instrum. 64 2064-5
    • (1993) Rev. Sci. Instrum. , vol.64 , pp. 2064-2065
    • Chu, W.T.1    Ludewigt, B.A.2    Renner, T.R.3
  • 2
    • 0010428399 scopus 로고
    • Charged particle method-protons and heavy charged particles
    • ed M H Phillips (New York: Plenum)
    • Frankel K and Phillips M H 1993 Charged particle method-protons and heavy charged particles Physical Aspects of Stereotactic Radiosurgery ed M H Phillips (New York: Plenum) pp 239-78
    • (1993) Physical Aspects of Stereotactic Radiosurgery , pp. 239-278
    • Frankel, K.1    Phillips, M.H.2
  • 4
    • 0345550902 scopus 로고    scopus 로고
    • Determination of dose distributions in a clinical proton beam using silicon diode detectors
    • submitted
    • Grusell E and Medin J 1999 Determination of dose distributions in a clinical proton beam using silicon diode detectors Phys. Med. Biol. submitted
    • (1999) Phys. Med. Biol.
    • Grusell, E.1    Medin, J.2
  • 5
    • 0030026160 scopus 로고    scopus 로고
    • A comparison of dosimetry techniques in stereotactic radiosurgery
    • Heydarian M, Hoban P W and Beddoe A H 1996 A comparison of dosimetry techniques in stereotactic radiosurgery Phys. Med. Biol. 41 93-110
    • (1996) Phys. Med. Biol. , vol.41 , pp. 93-110
    • Heydarian, M.1    Hoban, P.W.2    Beddoe, A.H.3
  • 6
    • 0345550901 scopus 로고    scopus 로고
    • Clinical proton dosimetry part 1: Beam production, beam delivery and measurements of absorbed dose
    • Washington, DC: ICRU
    • International Commission on Radiation Units and Measurements (ICRU) 1998 Clinical proton dosimetry part 1: beam production, beam delivery and measurements of absorbed dose ICRU Report 59 (Washington, DC: ICRU) pp 18-19, 33-34
    • (1998) ICRU Report , vol.59 , pp. 18-19
  • 9
    • 0023200203 scopus 로고
    • Equipment for radiation surgery using narrow 185 MeV proton beams: Dosimetry and design
    • Larsson B and Sarby B 1987 Equipment for radiation surgery using narrow 185 MeV proton beams: dosimetry and design Acta Oncol. 26 143-58
    • (1987) Acta Oncol. , vol.26 , pp. 143-158
    • Larsson, B.1    Sarby, B.2
  • 10
    • 0013539134 scopus 로고
    • Clinical applications of stereotactic radiosurgery
    • ed M H Phillips (New York: Plenum)
    • Levy R P and Fabricant J I 1993 Clinical applications of stereotactic radiosurgery Physical Aspects of Stereotactic Radiosurgery ed M H Phillips (New York: Plenum) pp 239-78
    • (1993) Physical Aspects of Stereotactic Radiosurgery , pp. 239-278
    • Levy, R.P.1    Fabricant, J.I.2
  • 13
    • 38249011340 scopus 로고
    • Stopping powers for the ion-chamber dosimetry of radiotherpeutic heavy-particle beams
    • Medin J and Andreo P 1992 Stopping powers for the ion-chamber dosimetry of radiotherpeutic heavy-particle beams Nucl. Instrum. Methods Phys. Res. B 69 64-75
    • (1992) Nucl. Instrum. Methods Phys. Res. B , vol.69 , pp. 64-75
    • Medin, J.1    Andreo, P.2
  • 14
    • 0028787608 scopus 로고
    • Review of proton beam radiation therapy
    • Miller D 1995 Review of proton beam radiation therapy Med. Phys. 22 1943-54
    • (1995) Med. Phys. , vol.22 , pp. 1943-1954
    • Miller, D.1
  • 15
    • 0343053221 scopus 로고
    • Generation and characterization of a proton microbeam
    • Moyers M F 1992 Generation and characterization of a proton microbeam Med. Phys. 20 867
    • (1992) Med. Phys. , vol.20 , pp. 867
    • Moyers, M.F.1
  • 16
    • 0344688779 scopus 로고
    • The effect of scattering on small proton beam
    • Department of Physics, Harvard University, Cambridge, MA
    • Preston W M and Koehler A M 1968 The effect of scattering on small proton beam Internal Report (Department of Physics, Harvard University, Cambridge, MA)
    • (1968) Internal Report
    • Preston, W.M.1    Koehler, A.M.2
  • 17
    • 0026786858 scopus 로고
    • Tissue maximum ratios and other parameters of small circular 4, 6, 10.15 and 24 MV x-ray beams for radiosurgery
    • Serago C F, Houdek P V, Hartmann G H, Saini D S, Serago M E and Kaydee A 1992 Tissue maximum ratios and other parameters of small circular 4, 6, 10.15 and 24 MV x-ray beams for radiosurgery Phys. Med. Biol. 37 1943-56
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1943-1956
    • Serago, C.F.1    Houdek, P.V.2    Hartmann, G.H.3    Saini, D.S.4    Serago, M.E.5    Kaydee, A.6
  • 19
    • 0012117662 scopus 로고    scopus 로고
    • Study of small proton beam field
    • Takada Y 1996 Study of small proton beam field Particles 18 A35
    • (1996) Particles , vol.18
    • Takada, Y.1
  • 21
    • 0031148917 scopus 로고    scopus 로고
    • Radiochromic film dosimetry for clinical proton beams
    • Vatnitsky S M 1997 Radiochromic film dosimetry for clinical proton beams Appl. Radiat. Isot. 45 643-51
    • (1997) Appl. Radiat. Isot. , vol.45 , pp. 643-651
    • Vatnitsky, S.M.1
  • 23
    • 0028919685 scopus 로고
    • Application of solid state detectors for dosimetry of therapeutic proton beams
    • Vatnitsky S, Miller D, Siebers J and Moyers M 1995 Application of solid state detectors for dosimetry of therapeutic proton beams Med. Phys. 22 469-73
    • (1995) Med. Phys. , vol.22 , pp. 469-473
    • Vatnitsky, S.1    Miller, D.2    Siebers, J.3    Moyers, M.4
  • 24
    • 0030294893 scopus 로고    scopus 로고
    • Proton dosimetry intercomparison
    • Vatnitsky S et al 1996 Proton dosimetry intercomparison Radiother. Oncol. 41 169-77
    • (1996) Radiother. Oncol. , vol.41 , pp. 169-177
    • Vatnitsky, S.1
  • 25
    • 0030756665 scopus 로고    scopus 로고
    • Radiochromic film dosimetry for verification of dose distributions delivered with proton-beam radiosurgery
    • Vatnitsky S M, Schulte R W M, Galindo R-M, Meinass H J and Miller D W 1997 Radiochromic film dosimetry for verification of dose distributions delivered with proton-beam radiosurgery Phys. Med. Biol. 42 1887-98
    • (1997) Phys. Med. Biol. , vol.42 , pp. 1887-1898
    • Vatnitsky, S.M.1    Schulte Rw, M.2    Galindo, R.-M.3    Meinass, H.J.4    Miller, D.W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.