메뉴 건너뛰기




Volumn 12, Issue 3, 1999, Pages 315-320

New developments in the management of the paediatric airway: Cuffed or uncuffed tracheal tubes, laryngeal mask airway, cuffed oropharyngeal airway, tracheostomy and one-lung ventilation devices

Author keywords

[No Author keywords available]

Indexed keywords

NITROUS OXIDE;

EID: 0032726312     PISSN: 09527907     EISSN: None     Source Type: Journal    
DOI: 10.1097/00001503-199906000-00010     Document Type: Review
Times cited : (14)

References (34)
  • 1
    • 0031880531 scopus 로고    scopus 로고
    • Absence or presence of a leak around tracheal tube may not affect postoperative croup in children
    • Khalil SN, Mankarious R, Campos C, Chuang AZ, Lemak NA. Absence or presence of a leak around tracheal tube may not affect postoperative croup in children. Paediatr Anaesth 1998; 8:393-396. An interesting study despite its limitations such as the small number of children with no leak around the endotracheal tube and only one anaesthesiologist being involved.
    • (1998) Paediatr Anaesth , vol.8 , pp. 393-396
    • Khalil, S.N.1    Mankarious, R.2    Campos, C.3    Chuang, A.Z.4    Lemak, N.A.5
  • 2
    • 0030942862 scopus 로고    scopus 로고
    • Comparison of cuffed and uncuffed endotracheal tubes in young children during general anesthesia
    • Khine HH, Corddry DH, Kettrick RG, Martin TM, McCloskey JJ, Rose JB, et al. Comparison of cuffed and uncuffed endotracheal tubes in young children during general anesthesia. Anesthesiology 1997; 86:627-631. The rather high rate of early respiratory complications in the children intubated with uncuffed tubes weakens the conclusions drawn from this otherwise well-conducted and challenging study.
    • (1997) Anesthesiology , vol.86 , pp. 627-631
    • Khine, H.H.1    Corddry, D.H.2    Kettrick, R.G.3    Martin, T.M.4    McCloskey, J.J.5    Rose, J.B.6
  • 3
    • 0021843803 scopus 로고
    • Factors affecting leak around tracheal tubes in children
    • Finholt DA, Henry DB, Raphaely RC. Factors affecting leak around tracheal tubes in children. Can Anaesth Soc J 1985; 32:326-329.
    • (1985) Can Anaesth Soc J , vol.32 , pp. 326-329
    • Finholt, D.A.1    Henry, D.B.2    Raphaely, R.C.3
  • 5
    • 0029891326 scopus 로고    scopus 로고
    • Cuff bulk of tracheal tubes in adolescence
    • Jones R, Ueda I. Cuff bulk of tracheal tubes in adolescence. Can J Anaesth 1996; 43:514-517.
    • (1996) Can J Anaesth , vol.43 , pp. 514-517
    • Jones, R.1    Ueda, I.2
  • 6
    • 0028124605 scopus 로고
    • MRI image degradation from an endotracheal tube pilot balloon
    • Brenn BR, Saldutti G. MRI image degradation from an endotracheal tube pilot balloon. Anesth Analg 1994; 79:586-587.
    • (1994) Anesth Analg , vol.79 , pp. 586-587
    • Brenn, B.R.1    Saldutti, G.2
  • 7
    • 0030736408 scopus 로고    scopus 로고
    • The laryngeal mask airway
    • International Anesthesiology Clinics. Borland LW (editor). Philadelphia: Lippincott-Raven Publishers
    • Landsman IS. The laryngeal mask airway. In: Airway management in pediatric anesthesia. International Anesthesiology Clinics. Borland LW (editor). Philadelphia: Lippincott-Raven Publishers; 1997. pp. 49-65. A thorough review of the literature on the use of the LMA in children.
    • (1997) Airway Management in Pediatric Anesthesia , pp. 49-65
    • Landsman, I.S.1
  • 8
    • 0031829143 scopus 로고    scopus 로고
    • Laryngeal Mask Airway and the Pediatric Patient
    • International Anesthesiology Clinics. Ferson OZ, Brimacombe JR, Brain AU (editors) Philadelphia: Lippincott-Raven Publishers
    • Boehringer LA, Bennie RE. Laryngeal mask airway and the pediatric patient. In: The laryngeal mask airway. International Anesthesiology Clinics. Ferson OZ, Brimacombe JR, Brain AU (editors). Philadelphia: Lippincott-Raven Publishers; 1998. pp. 45-60.
    • (1998) The Laryngeal Mask Airway , pp. 45-60
    • Boehringer, L.A.1    Bennie, R.E.2
  • 9
    • 0030846240 scopus 로고    scopus 로고
    • The modified laryngeal mask airway: Four head and neck procedures in two children with mild subglottic stenosis
    • Rothschild MA, Kavee EH. The modified laryngeal mask airway: four head and neck procedures in two children with mild subglottic stenosis. Int J Pediatr Otorhinolaryngol 1997; 41:163-173. A trick to remember? In order to facilitate surgical access for ENT or ophthalmic surgery without using a reinforced LMA and a mouth gag, the authors adapted a malleable intubation stylet outside the LMA with adhesive tape: this allowed positioning of the breathing system away from the surgical field.
    • (1997) Int J Pediatr Otorhinolaryngol , vol.41 , pp. 163-173
    • Rothschild, M.A.1    Kavee, E.H.2
  • 10
    • 0031725026 scopus 로고    scopus 로고
    • Assisted ventilation through a laryngeal mask airway for severe subglottic stenosis
    • Bahk JH, Rhee K-Y. Assisted ventilation through a laryngeal mask airway for severe subglottic stenosis [letter]. Paediatr Anaesth 1998; 8:523.
    • (1998) Paediatr Anaesth , vol.8 , pp. 523
    • Bahk, J.H.1    Rhee, K.-Y.2
  • 11
    • 0030874244 scopus 로고    scopus 로고
    • Intermittent positive ventilation through a laryngeal mask in children: Does it cause gastric dilatation?
    • Selby IR, Morris P. Intermittent positive ventilation through a laryngeal mask in children: does it cause gastric dilatation? Paediatr Anaesth 1997; 7:305-308.
    • (1997) Paediatr Anaesth , vol.7 , pp. 305-308
    • Selby, I.R.1    Morris, P.2
  • 12
    • 0031915099 scopus 로고    scopus 로고
    • The effect of nitrous oxide diffusion on laryngeal mask airway cuff inflation in children
    • Algren JT, Gursoy F, Johnson TD, Skjonsky BS. The effect of nitrous oxide diffusion on laryngeal mask airway cuff inflation in children. Paediatr Anaesth 1998, 8:31-36. An in-vivo and in-vitro study of the effects of nitrous oxide on size 2 LMA cuff inflation in 52 children. A large discussion based on a thorough review of the literature.
    • (1998) Paediatr Anaesth , vol.8 , pp. 31-36
    • Algren, J.T.1    Gursoy, F.2    Johnson, T.D.3    Skjonsky, B.S.4
  • 13
    • 0029913442 scopus 로고    scopus 로고
    • Airway sealing pressures of the laryngeal mask airway in pediatric patients
    • Epstein RH, Ferouz F, Jenkins MA. Airway sealing pressures of the laryngeal mask airway in pediatric patients. J Clin Anesth 1996; 8:93-98.
    • (1996) J Clin Anesth , vol.8 , pp. 93-98
    • Epstein, R.H.1    Ferouz, F.2    Jenkins, M.A.3
  • 14
    • 0031671185 scopus 로고    scopus 로고
    • Saline as an alternative to air for filling the laryngeal mask airway
    • Coorey A, Brimacombe J, Keller C. Saline as an alternative to air for filling the laryngeal mask airway. Br J Anaesth 1998; 81:398-400.
    • (1998) Br J Anaesth , vol.81 , pp. 398-400
    • Coorey, A.1    Brimacombe, J.2    Keller, C.3
  • 15
    • 0030053061 scopus 로고    scopus 로고
    • Positive pressure ventilation with the laryngeal mask airway in children
    • Gursoy F, Algren JT, Skjonsky BS. Positive pressure ventilation with the laryngeal mask airway in children. Anesth Analg 1996; 82:33-38.
    • (1996) Anesth Analg , vol.82 , pp. 33-38
    • Gursoy, F.1    Algren, J.T.2    Skjonsky, B.S.3
  • 18
    • 0031954826 scopus 로고    scopus 로고
    • Tracheostomy in the young pediatric burn patient
    • Coln CE, Purdue GF, Hunt JL. Tracheostomy in the young pediatric burn patient. Arch Surg 1998; 133:537-540.
    • (1998) Arch Surg , vol.133 , pp. 537-540
    • Coln, C.E.1    Purdue, G.F.2    Hunt, J.L.3
  • 20
    • 0031924261 scopus 로고    scopus 로고
    • Complications of percutaneous dilatational tracheostomy in children
    • Scott CJ, Darowski M, Crabbe DCG. Complications of percutaneous dilatational tracheostomy in children. Anaesthesia 1998; 53:477-480. A report of one case of tracheal stenosis and one case of granulation above the tracheostomy after apparently easy percutaneous dilatational tracheostomy in children. A discussion on the safety of this technique in paediatric patients is presented.
    • (1998) Anaesthesia , vol.53 , pp. 477-480
    • Scott, C.J.1    Darowski, M.2    Crabbe, D.C.G.3
  • 21
    • 0031662819 scopus 로고    scopus 로고
    • Percutaneous dilatational tracheostomy in children
    • Bell MDD. Percutaneous dilatational tracheostomy in children [letter]. Anaesthesia 1998; 53:931.
    • (1998) Anaesthesia , vol.53 , pp. 931
    • Bell, M.D.D.1
  • 22
    • 0031004267 scopus 로고    scopus 로고
    • A non-derivative, non-surgical tracheostomy: The translaryngeal method
    • Fantoni A, Ripamonti D. A non-derivative, non-surgical tracheostomy: the translaryngeal method. Intens Care Med 1997; 23:386-392. A full description of TLT in adults and children by the team who developed the technique and equipment.
    • (1997) Intens Care Med , vol.23 , pp. 386-392
    • Fantoni, A.1    Ripamonti, D.2
  • 23
    • 0030820001 scopus 로고    scopus 로고
    • Spillage of cystic pulmonary masses into the airway during anesthesia
    • Politis GD, Baumann R, Hubbard AM. Spillage of cystic pulmonary masses into the airway during anesthesia. Anesthesiology 1997; 87:693-696.
    • (1997) Anesthesiology , vol.87 , pp. 693-696
    • Politis, G.D.1    Baumann, R.2    Hubbard, A.M.3
  • 24
    • 0031810486 scopus 로고    scopus 로고
    • A modified endotracheal tube for infants and small children undergoing video-assisted thoracoscopic surgery
    • Tan PCP, Chu J, Ho ACY, Cheng K-S, Lin PJ, Chang C-H. A modified endotracheal tube for infants and small children undergoing video-assisted thoracoscopic surgery. Anesth Analg 1998; 86:1212-1213. The modification of the endotracheal tube consists of cutting a U-shaped notch opposite to Murphy's eye in order to enlarge the bevel of a standard tracheal tube; this prevents blocking of the right upper lobe bronchus in a case of selective right mainstem bronchus intubation.
    • (1998) Anesth Analg , vol.86 , pp. 1212-1213
    • Tan, P.C.P.1    Chu, J.2    Ho, A.C.Y.3    Cheng, K.-S.4    Lin, P.J.5    Chang, C.-H.6
  • 25
    • 0000934689 scopus 로고
    • Selective endobronchial intubation in paediatrics: The Marraro Paediatric Bilumen tube
    • Marraro G. Selective endobronchial intubation in paediatrics: the Marraro Paediatric Bilumen tube. Paediatr Anaesth 1994; 4:255-258.
    • (1994) Paediatr Anaesth , vol.4 , pp. 255-258
    • Marraro, G.1
  • 26
    • 0030331344 scopus 로고    scopus 로고
    • Right bevelled tube for selective left bronchial intubation in a child undergoing right thoracotomy
    • Baraka A. Right bevelled tube for selective left bronchial intubation in a child undergoing right thoracotomy. Paediatr Anaesth 1996; 6:487-489.
    • (1996) Paediatr Anaesth , vol.6 , pp. 487-489
    • Baraka, A.1
  • 27
    • 0031854336 scopus 로고    scopus 로고
    • Bronchial injury during lung isolation in a pediatric patient
    • Borchardt RA, LaQuaglia MP, McDowall RH, Wilson RS. Bronchial injury during lung isolation in a pediatric patient. Anesth Analg 1998; 87:324-325. A case report describing the perforation of the membranous portion of the right mainstem bronchus by a 5 F Fogarty embolectomy catheter inadvertently inflated with 4 ml of air instead of 3 ml.
    • (1998) Anesth Analg , vol.87 , pp. 324-325
    • Borchardt, R.A.1    LaQuaglia, M.P.2    McDowall, R.H.3    Wilson, R.S.4
  • 28
    • 0031913634 scopus 로고    scopus 로고
    • The Univent tube for single-lung intubation in paediatric patients
    • Hammer GB, Brodsky JB, Redpath JH, Cannon WB. The Univent tube for single-lung intubation in paediatric patients. Paediatr Anaesth 1998; 8:55-57. The discussion contains an overview of the equipment available for one-lung ventilation in big children and adolescents.
    • (1998) Paediatr Anaesth , vol.8 , pp. 55-57
    • Hammer, G.B.1    Brodsky, J.B.2    Redpath, J.H.3    Cannon, W.B.4
  • 29
    • 0029920264 scopus 로고    scopus 로고
    • Removal of the laryngeal mask airway in children: Anaesthetized compared with awake
    • Kitching AJ, Walpole AR, Blogg CE. Removal of the laryngeal mask airway in children: anaesthetized compared with awake. Br J Anaesth 1996; 76:874-876.
    • (1996) Br J Anaesth , vol.76 , pp. 874-876
    • Kitching, A.J.1    Walpole, A.R.2    Blogg, C.E.3
  • 31
    • 0031945156 scopus 로고    scopus 로고
    • Awake removal of the laryngeal mask airway is safe in paediatric patients
    • Samarkandi AH. Awake removal of the laryngeal mask airway is safe in paediatric patients. Can J Anaesth 1998; 45:150-152.
    • (1998) Can J Anaesth , vol.45 , pp. 150-152
    • Samarkandi, A.H.1
  • 32
    • 0032031907 scopus 로고    scopus 로고
    • Pulmonary aspiration in pediatric patients during general anesthesia: Incidence and outcome
    • Borland LM, Sereika SM, Woelfeld SK, Saltz EW, Carrillo PA, Lupin JL, Motoyama EK. Pulmonary aspiration in pediatric patients during general anesthesia: incidence and outcome. J Clin Anesth 1998; 10:95-102. Analysis of a database of 50880 pediatric patients undergoing general anaesthesia in a 5 year period: although low (0.10%) the incidence of anaesthesia-related aspiration was twice that reported in adults. Many risk factors (age, emergency, ASA status, time of day, induction method etc.) are analysed.
    • (1998) J Clin Anesth , vol.10 , pp. 95-102
    • Borland, L.M.1    Sereika, S.M.2    Woelfeld, S.K.3    Saltz, E.W.4    Carrillo, P.A.5    Lupin, J.L.6    Motoyama, E.K.7
  • 33
    • 0029851782 scopus 로고    scopus 로고
    • Safety and efficacy of the laryngeal mask airway: A prospective survey of 1400 children
    • Lopez-Gil M, Brimacombe J. Safety and efficacy of the laryngeal mask airway: a prospective survey of 1400 children. Anaesthesia 1996; 51:969-972.
    • (1996) Anaesthesia , vol.51 , pp. 969-972
    • Lopez-Gil, M.1    Brimacombe, J.2
  • 34
    • 0031782832 scopus 로고    scopus 로고
    • Assessment of oropharyngeal distance in children using magnetic resonance imaging
    • Greenberg RS, Zahurak M, Belden C, Tunkel DE. Assessment of oropharyngeal distance in children using magnetic resonance imaging. Anesth Analg 1998; 87:1048-1051. Reviewing 200 MRI head scans of children 0-17 years old, the authors measured the midline distance from the gums/teeth to the prevertebral space and from this line to the tip of the epiglottis. The oropharyngeal distance is related to age, weight and sex, and the distance to the epiglottis is highly variable.
    • (1998) Anesth Analg , vol.87 , pp. 1048-1051
    • Greenberg, R.S.1    Zahurak, M.2    Belden, C.3    Tunkel, D.E.4