Volumn 8, Issue 1, 1998, Pages 31-36

The effect of nitrous oxide diffusion on laryngeal mask airway cuff inflation in children

Author keywords

Laryngeal mask airway (LMA); LMA cuff overinflation; Nitrous oxide diffusion

Indexed keywords

HALOTHANE; NITROUS OXIDE; OXYGEN;

EID: 0031915099     PISSN: 11555645     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.1998.00696.x     Document Type: Article
Times cited : (14)

References (20)
  • 1
    • 0025831826 scopus 로고
    • Trauma to the posterior wall of pharynx caused by a laryngeal mask airway
    • Marjot R. Trauma to the posterior wall of pharynx caused by a laryngeal mask airway. Anaesthesia 1991; 46: 589-590.
    • (1991) Anaesthesia , vol.46 , pp. 589-590
    • Marjot, R.1
  • 2
    • 0342902625 scopus 로고    scopus 로고
    • The effect of laryngeal mask cuff pressure on postoperative sore throat incidence
    • Burgard G, Mollhoff T, Prien T. The effect of laryngeal mask cuff pressure on postoperative sore throat incidence. J Clin Anesth 1996; 8: 198-201.
    • (1996) J Clin Anesth , vol.8 , pp. 198-201
    • Burgard, G.1    Mollhoff, T.2    Prien, T.3
  • 3
    • 0028284660 scopus 로고
    • Unilateral hypoglossal nerve paralysis following the use of the laryngeal mask airway
    • Nagai K, Sakuramoto C, Goto F. Unilateral hypoglossal nerve paralysis following the use of the laryngeal mask airway. Anaesthesia 1994; 49: 603-604.
    • (1994) Anaesthesia , vol.49 , pp. 603-604
    • Nagai, K.1    Sakuramoto, C.2    Goto, F.3
  • 4
    • 0028930622 scopus 로고
    • Transient bilateral vocal cord paralysis after insertion of a laryngeal mask airway
    • Inomata S, Nishikawa T, Suga A, et al. Transient bilateral vocal cord paralysis after insertion of a laryngeal mask airway. Anesthesiology 1995; 82: 787-788.
    • (1995) Anesthesiology , vol.82 , pp. 787-788
    • Inomata, S.1    Nishikawa, T.2    Suga, A.3
  • 5
    • 0030077068 scopus 로고    scopus 로고
    • Recurrent laryngeal nerve palsy after laryngeal mask airway insertion
    • Lloyd Jones FR, Hegab A. Recurrent laryngeal nerve palsy after laryngeal mask airway insertion. Anaesthesia 1996; 51: 171-172.
    • (1996) Anaesthesia , vol.51 , pp. 171-172
    • Lloyd Jones, F.R.1    Hegab, A.2
  • 6
    • 0029942534 scopus 로고    scopus 로고
    • Vocal cord palsy after use of the laryngeal mask airway
    • Daya H, Fawcett WJ, Weir N. Vocal cord palsy after use of the laryngeal mask airway. J Laryngol Otol 1996; 110: 383-384.
    • (1996) J Laryngol Otol , vol.110 , pp. 383-384
    • Daya, H.1    Fawcett, W.J.2    Weir, N.3
  • 7
    • 0031044258 scopus 로고
    • Severe dysphonia after use of a laryngeal mask airway
    • Cros AM, Pitti R, Conil C, et al. Severe dysphonia after use of a laryngeal mask airway. Anesthesiology 1947; 86: 498-500.
    • (1947) Anesthesiology , vol.86 , pp. 498-500
    • Cros, A.M.1    Pitti, R.2    Conil, C.3
  • 8
    • 0025499587 scopus 로고
    • Will we ever learn?
    • Welsh BE. Will we ever learn? (letter). Anaesthesia 1990; 45: 892.
    • (1990) Anaesthesia , vol.45 , pp. 892
    • Welsh, B.E.1
  • 9
    • 0025774777 scopus 로고
    • A hazard with the laryngeal mask airway
    • Collier C. A hazard with the laryngeal mask airway (letter). Anaesth Intens Care 1991; 19: 301.
    • (1991) Anaesth Intens Care , vol.19 , pp. 301
    • Collier, C.1
  • 11
    • 0026566057 scopus 로고
    • The effect of nitrous oxide on laryngeal mask cuff pressure
    • Lumb AB, Wrigley MW. The effect of nitrous oxide on laryngeal mask cuff pressure. Anaesthesia 1992; 47: 320-323.
    • (1992) Anaesthesia , vol.47 , pp. 320-323
    • Lumb, A.B.1    Wrigley, M.W.2
  • 12
    • 0027530403 scopus 로고
    • Pressure exerted by the laryngeal mask airway cuff upon the pharyngeal mucosa
    • Marjot R. Pressure exerted by the laryngeal mask airway cuff upon the pharyngeal mucosa. Br J Anaesth 1993; 70: 25-29.
    • (1993) Br J Anaesth , vol.70 , pp. 25-29
    • Marjot, R.1
  • 14
    • 0028015750 scopus 로고
    • Laryngeal mask airway cuff pressure and position during anaesthesia lasting one to two hours
    • Brimacombe J, Berry A. Laryngeal mask airway cuff pressure and position during anaesthesia lasting one to two hours. Can J Anaesth 1994; 41: 589-593.
    • (1994) Can J Anaesth , vol.41 , pp. 589-593
    • Brimacombe, J.1    Berry, A.2
  • 15
    • 0030053061 scopus 로고    scopus 로고
    • Positive pressure ventilation with the laryngeal mask airway in children
    • Gursoy F, Algren JT, Skjonsby BS. Positive pressure ventilation with the laryngeal mask airway in children. Anesth Analg 1996; 82: 33-38.
    • (1996) Anesth Analg , vol.82 , pp. 33-38
    • Gursoy, F.1    Algren, J.T.2    Skjonsby, B.S.3
  • 16
    • 0025247080 scopus 로고
    • The laryngeal mask airway in paediatric anaesthesia
    • Johnston DF, Wrigley SR, Robb PJ, et al. The laryngeal mask airway in paediatric anaesthesia. Anaesthesia 1990; 45: 924-927.
    • (1990) Anaesthesia , vol.45 , pp. 924-927
    • Johnston, D.F.1    Wrigley, S.R.2    Robb, P.J.3
  • 17
    • 0024729872 scopus 로고
    • Incidence of sore throats with the laryngeal mask
    • Alexander CA, Leach AB. Incidence of sore throats with the laryngeal mask (letter). Anaesthesia 1989; 44: 791.
    • (1989) Anaesthesia , vol.44 , pp. 791
    • Alexander, C.A.1    Leach, A.B.2
  • 18
    • 0028355548 scopus 로고
    • A comparative study of the incidence of sore throat with the laryngeal mask airway
    • Dingley J, Whitehead MJ. A comparative study of the incidence of sore throat with the laryngeal mask airway. Anaesthesia 1994; 49: 251-254.
    • (1994) Anaesthesia , vol.49 , pp. 251-254
    • Dingley, J.1    Whitehead, M.J.2
  • 19
    • 0030036024 scopus 로고    scopus 로고
    • Optimal intracuff pressures with the laryngeal mask
    • Brimacombe J, Berry A, Brain AIJ. Optimal intracuff pressures with the laryngeal mask (letter). Br J Anaesth 1996; 77: 295-296.
    • (1996) Br J Anaesth , vol.77 , pp. 295-296
    • Brimacombe, J.1    Berry, A.2    Brain, A.I.J.3
  • 20
    • 0030160460 scopus 로고    scopus 로고
    • Pressure in laryngeal mask airway cuffs
    • Brain AIJ. Pressure in laryngeal mask airway cuffs (letter). Anaesthesia 1996; 51: 603.
    • (1996) Anaesthesia , vol.51 , pp. 603
    • Brain, A.I.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.